CISCO-UNIFIED-COMPUTING-MEMORY-MIB :: cucsMemoryRuntimeDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-MEMORY-MIBcucsMemoryRuntimeDn

cucsMemoryRuntimeDn

Module: CISCO-UNIFIED-COMPUTING-MEMORY-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryRuntimeDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.30.9.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS memory:Runtime:dn managed object property

What is cucsMemoryRuntimeDn?

This string holds the Dn (Distinguished Name), the full slash-delimited path that uniquely locates this memory array's runtime utilization stats object inside the UCS Manager information tree, as the description confirms it is simply the object's own dn property. An admin or a monitoring tool uses this exact string as the target when polling or filtering for this specific memory array's runtime utilization stats instance rather than any other one on the chassis. For example, the value might look like 'sys/chassis-1/blade-3/board/memarray-1/mem-1' identifying one particular DIMM slot on blade 3.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.9.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryRuntimeDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.9.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryRuntimeDn.1

Start monitoring Cisco UCS blade/rack servers (physical memory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryRuntimeDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers (physical memory) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.30cucsMemoryObjectsCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.9cucsMemoryRuntimeTableCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.9.1cucsMemoryRuntimeEntryCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.9.1.2cucsMemoryRuntimeDnCISCO-UNIFIED-COMPUTING-MEMORY-MIB