CISCO-UNIFIED-COMPUTING-MEMORY-MIB :: cucsMemoryErrorStatsThresholded

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-MEMORY-MIBcucsMemoryErrorStatsThresholded

cucsMemoryErrorStatsThresholded

Module: CISCO-UNIFIED-COMPUTING-MEMORY-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryErrorStatsThresholded

OID (numeric): 1.3.6.1.4.1.9.9.719.1.30.7.1.42

Node type: OBJECT-TYPE

Type: CucsMemoryErrorStatsThresholded

Access: read-only

Description: Cisco UCS memory:ErrorStats:thresholded managed object property

What is cucsMemoryErrorStatsThresholded?

This enumerated value (CucsMemoryErrorStatsThresholded) reports which of the numeric fields in this memory unit's error-counter stats record have crossed a configured alarm threshold, per its thresholded property description. It gives an admin a single field to check instead of comparing every counter in the memory unit's error-counter stats table against its own limit to see if something needs attention. A value of 0 means nothing is out of range, while a nonzero bitmask flags exactly which of this record's counters (say, temperature or an error count) breached its threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.7.1.42
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryErrorStatsThresholded

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.7.1.42.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryErrorStatsThresholded.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsMemoryErrorStatsThresholded.1

Start monitoring Cisco UCS blade/rack servers (physical memory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryErrorStatsThresholded OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers (physical memory) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.30cucsMemoryObjectsCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.7cucsMemoryErrorStatsTableCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.7.1cucsMemoryErrorStatsEntryCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.7.1.42cucsMemoryErrorStatsThresholdedCISCO-UNIFIED-COMPUTING-MEMORY-MIB