CISCO-UNIFIED-COMPUTING-MEMORY-MIB :: cucsMemoryBufferUnitLocationDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-MEMORY-MIBcucsMemoryBufferUnitLocationDn

cucsMemoryBufferUnitLocationDn

Module: CISCO-UNIFIED-COMPUTING-MEMORY-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryBufferUnitLocationDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.30.4.1.17

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS memory:BufferUnit:locationDn managed object property

What is cucsMemoryBufferUnitLocationDn?

This SnmpAdminString holds the Dn of the physical location container the memory buffer unit sits in, per its locationDn property description. An admin uses this specific path to jump straight to the slot's physical location context in UCS Manager without recomputing it from the buffer unit's own Dn. A typical value looks like 'sys/chassis-1/blade-3/board/memarray-1'.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.4.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryBufferUnitLocationDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.4.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryBufferUnitLocationDn.1

Start monitoring Cisco UCS blade/rack servers (physical memory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryBufferUnitLocationDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers (physical memory) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.30cucsMemoryObjectsCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.4cucsMemoryBufferUnitTableCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.4.1cucsMemoryBufferUnitEntryCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.4.1.17cucsMemoryBufferUnitLocationDnCISCO-UNIFIED-COMPUTING-MEMORY-MIB