CISCO-UNIFIED-COMPUTING-MEMORY-MIB :: cucsMemoryArrayVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-MEMORY-MIBcucsMemoryArrayVoltage

cucsMemoryArrayVoltage

Module: CISCO-UNIFIED-COMPUTING-MEMORY-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryArrayVoltage

OID (numeric): 1.3.6.1.4.1.9.9.719.1.30.1.1.21

Node type: OBJECT-TYPE

Type: CucsEquipmentSensorThresholdStatus

Access: read-only

Description: Cisco UCS memory:Array:voltage managed object property

What is cucsMemoryArrayVoltage?

This reports whether voltage sensor thresholds associated with this memory array have been crossed. An admin watches this specifically because unstable DIMM voltage is a common cause of intermittent memory errors, so a non-normal voltage status here points straight at a power-delivery issue on this array rather than a bad DIMM module itself. A value of lower-critical would indicate this array's memory voltage has dropped dangerously low, a likely root cause for correctable-error spikes reported on this same array.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.1.1.21
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryArrayVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.30.1.1.21.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryArrayVoltage.1

Start monitoring Cisco UCS blade/rack servers (physical memory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-MEMORY-MIB::cucsMemoryArrayVoltage OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers (physical memory) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.30cucsMemoryObjectsCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.1cucsMemoryArrayTableCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.1.1cucsMemoryArrayEntryCISCO-UNIFIED-COMPUTING-MEMORY-MIB
1.3.6.1.4.1.9.9.719.1.30.1.1.21cucsMemoryArrayVoltageCISCO-UNIFIED-COMPUTING-MEMORY-MIB