CISCO-UNIFIED-COMPUTING-LS-MIB :: cucsLsServerDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LS-MIBcucsLsServerDn

cucsLsServerDn

Module: CISCO-UNIFIED-COMPUTING-LS-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsServerDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.26.5.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS ls:Server:dn managed object property

What is cucsLsServerDn?

The MIB's DESCRIPTION for cucsLsServerDn is only the auto-generated stub 'Cisco UCS ls:Server:dn managed object property', but the 'dn' property name together with its CucsManagedObjectDn type tell us this column, on the service profile itself — the logical server definition applied to a physical blade, holds this object's distinguished name as UCS Manager's data model defines it, exposed here as a read-only SNMP value (read-only). On this device the Dn is the object's full path in UCS Manager's management information tree, so for the service profile itself — the logical server definition applied to a physical blade it is literally how UCS Manager, the CLI, and any NB-API/SNMP client agree on which service profile row a given set of columns belongs to — without it a poller has numbers with no way to tie them back to the object you'd click on in the GUI. For example this column might read 'org-root/ls-Web-Server-01', letting a script join this row straight back to that exact service profile.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.26.5.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsServerDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.26.5.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsServerDn.1

Start monitoring Cisco UCS Manager managed service profiles (logical servers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsServerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager managed service profiles (logical servers) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.26cucsLsObjectsCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.5cucsLsServerTableCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.5.1cucsLsServerEntryCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.5.1.2cucsLsServerDnCISCO-UNIFIED-COMPUTING-LS-MIB