CISCO-UNIFIED-COMPUTING-LS-MIB :: cucsLsFcLocaleSwitchId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-LS-MIBcucsLsFcLocaleSwitchId

cucsLsFcLocaleSwitchId

Module: CISCO-UNIFIED-COMPUTING-LS-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsFcLocaleSwitchId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.26.10.1.4

Node type: OBJECT-TYPE

Type: CucsNetworkSwitchId

Access: read-only

Description: Cisco UCS ls:FcLocale:switchId managed object property

What is cucsLsFcLocaleSwitchId?

The MIB's DESCRIPTION for cucsLsFcLocaleSwitchId is only the auto-generated stub 'Cisco UCS ls:FcLocale:switchId managed object property', but the 'switchId' property name together with its CucsNetworkSwitchId type tell us this column, on a per-fabric-switch Fibre Channel scoping entry (locale) attached to a service profile, holds the switchId as UCS Manager's data model defines it, exposed here as a read-only SNMP value (read-only). The switchId identifies which fabric switch (A or B) this Fibre Channel locale scopes its SAN configuration to, since UCS service profiles typically define independent FC settings per fabric side for redundancy. A service profile with dual-fabric SAN connectivity would have one FcLocale row with switchId A and another with switchId B.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.26.10.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsFcLocaleSwitchId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.26.10.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsFcLocaleSwitchId.1

Start monitoring Cisco UCS Manager managed service profiles (logical servers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-LS-MIB::cucsLsFcLocaleSwitchId OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager managed service profiles (logical servers) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.26cucsLsObjectsCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.10cucsLsFcLocaleTableCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.10.1cucsLsFcLocaleEntryCISCO-UNIFIED-COMPUTING-LS-MIB
1.3.6.1.4.1.9.9.719.1.26.10.1.4cucsLsFcLocaleSwitchIdCISCO-UNIFIED-COMPUTING-LS-MIB