All MIBs › CISCO-UNIFIED-COMPUTING-FC-MIB › cucsFcPIoType
cucsFcPIoType
Module: CISCO-UNIFIED-COMPUTING-FC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcPIoType
OID (numeric): 1.3.6.1.4.1.9.9.719.1.20.4.1.28
Node type: OBJECT-TYPE
Type: CucsNetworkConnectionType
Access: read-only
Description: Cisco UCS fc:PIo:type managed object property
What is cucsFcPIoType?
This reports the kind of connection this physical FC port represents, e.g. an uplink toward the SAN fabric versus a server-facing or storage-facing connection type. For this port, the connection type governs which configuration options UCS Manager exposes and validates for it, similar to but distinct from ifRole, and mismatches here are another common cause of a port that's cabled correctly but still won't behave as the admin expects. For example, a port typed as a SAN uplink connection is configured and monitored differently from one typed as a direct storage-array connection, even if both are physically FC ports on the same module.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.20.4.1.28 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcPIoType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.20.4.1.28.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcPIoType.1
Start monitoring Cisco UCS Fabric Interconnect (Fibre Channel) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcPIoType OID value, configure state conditions and alerts, and monitor any Cisco UCS Fabric Interconnect (Fibre Channel) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.20 | cucsFcObjects | CISCO-UNIFIED-COMPUTING-FC-MIB |
| 1.3.6.1.4.1.9.9.719.1.20.4 | cucsFcPIoTable | CISCO-UNIFIED-COMPUTING-FC-MIB |
| 1.3.6.1.4.1.9.9.719.1.20.4.1 | cucsFcPIoEntry | CISCO-UNIFIED-COMPUTING-FC-MIB |
| 1.3.6.1.4.1.9.9.719.1.20.4.1.28 | cucsFcPIoType | CISCO-UNIFIED-COMPUTING-FC-MIB |