cucsFcErrStatsSuspect

Module: CISCO-UNIFIED-COMPUTING-FC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcErrStatsSuspect

OID (numeric): 1.3.6.1.4.1.9.9.719.1.20.1.1.35

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS fc:ErrStats:suspect managed object property

What is cucsFcErrStatsSuspect?

This TruthValue flag marks whether UCS Manager considers the counters in this specific FC port's error-stats record unreliable right now, for example because the port was mid-transition when the sample was taken. For live FC error statistics, checking this before reacting to a counter spike matters because a suspect sample can produce a misleading burst of apparent errors that has nothing to do with real link quality. For example, suspect flips true for one sampling cycle right as a port comes back up after a reboot, then clears on the next cycle once readings stabilize.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.20.1.1.35
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcErrStatsSuspect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.20.1.1.35.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcErrStatsSuspect.1

Start monitoring Cisco UCS Fabric Interconnect (Fibre Channel) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FC-MIB::cucsFcErrStatsSuspect OID value, configure state conditions and alerts, and monitor any Cisco UCS Fabric Interconnect (Fibre Channel) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.20cucsFcObjectsCISCO-UNIFIED-COMPUTING-FC-MIB
1.3.6.1.4.1.9.9.719.1.20.1cucsFcErrStatsTableCISCO-UNIFIED-COMPUTING-FC-MIB
1.3.6.1.4.1.9.9.719.1.20.1.1cucsFcErrStatsEntryCISCO-UNIFIED-COMPUTING-FC-MIB
1.3.6.1.4.1.9.9.719.1.20.1.1.35cucsFcErrStatsSuspectCISCO-UNIFIED-COMPUTING-FC-MIB