CISCO-UNIFIED-COMPUTING-FAULT-MIB :: cucsFaultPrevSeverity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FAULT-MIBcucsFaultPrevSeverity

cucsFaultPrevSeverity

Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPrevSeverity

OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.18

Node type: OBJECT-TYPE

Type: CucsFaultSeverity

Access: read-only

Description: Cisco UCS fault:Inst:prevSeverity managed object property

What is cucsFaultPrevSeverity?

This records the severity level this fault held immediately before its current severity. This gives an admin the one-step-back history needed to tell whether the fault's severity just changed, and in which direction, versus having been stable at its current level for a while, without needing to consult a full audit log. A previous severity of critical alongside a current severity of major would show the fault has just started de-escalating, which the admin might want to confirm continues rather than assume it's resolved.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.18
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPrevSeverity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.18.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPrevSeverity.1

Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPrevSeverity OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.1cucsFaultObjectsCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1cucsFaultTableCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1cucsFaultEntryCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1.18cucsFaultPrevSeverityCISCO-UNIFIED-COMPUTING-FAULT-MIB