CISCO-UNIFIED-COMPUTING-FAULT-MIB :: cucsFaultPolicyAckAction

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FAULT-MIBcucsFaultPolicyAckAction

cucsFaultPolicyAckAction

Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPolicyAckAction

OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.3.1.12

Node type: OBJECT-TYPE

Type: CucsConditionAckAction

Access: read-only

Description: Cisco UCS fault:Policy:ackAction managed object property

What is cucsFaultPolicyAckAction?

This defines what UCS Manager does with a fault once an admin acknowledges it - for example, whether acknowledgment automatically clears the fault or just marks it as seen while leaving the underlying condition tracked. This matters to an admin's workflow because acknowledging a fault to silence a page shouldn't necessarily be treated the same as confirming the underlying problem is actually fixed, so this setting controls whether those two actions are conflated or kept separate. An ack action that only marks a fault seen, rather than clearing it, means the fault stays listed as an open, acknowledged issue until its actual root cause resolves, even after the admin has already acknowledged it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.3.1.12
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPolicyAckAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.3.1.12.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPolicyAckAction.1

Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultPolicyAckAction OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.1cucsFaultObjectsCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.3cucsFaultPolicyTableCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.3.1cucsFaultPolicyEntryCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.3.1.12cucsFaultPolicyAckActionCISCO-UNIFIED-COMPUTING-FAULT-MIB