CISCO-UNIFIED-COMPUTING-FAULT-MIB :: cucsFaultOrigSeverity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FAULT-MIBcucsFaultOrigSeverity

cucsFaultOrigSeverity

Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultOrigSeverity

OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.17

Node type: OBJECT-TYPE

Type: CucsFaultSeverity

Access: read-only

Description: Cisco UCS fault:Inst:origSeverity managed object property

What is cucsFaultOrigSeverity?

This records the severity this fault was originally assigned when it was first raised. An admin compares this against the fault's current severity to see whether the condition has escalated or de-escalated over its lifetime, which matters for understanding whether a fault policy's escalation rules, for example after repeated occurrences, have kicked in. A fault with an original severity of minor that has since escalated to major shows the underlying condition worsened after it was first detected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultOrigSeverity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultOrigSeverity.1

Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultOrigSeverity OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.1cucsFaultObjectsCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1cucsFaultTableCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1cucsFaultEntryCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1.17cucsFaultOrigSeverityCISCO-UNIFIED-COMPUTING-FAULT-MIB