All MIBs › CISCO-UNIFIED-COMPUTING-FAULT-MIB › cucsFaultLc
cucsFaultLc
Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc
OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.15
Node type: OBJECT-TYPE
Type: CucsConditionLifecycle
Access: read-only
Description: Cisco UCS fault:Inst:lc managed object property
What is cucsFaultLc?
This reports the lifecycle stage of this fault - for example whether it is currently active/raising, soaking, or in the process of clearing. This tells an admin whether a fault that appears in the list is a live, currently-true condition or one that's already in the process of aging out per the fault policy's clear/retention settings, which changes whether immediate action is warranted. A lifecycle value of soaking means the underlying condition has to persist for the soak interval configured in the fault policy before this fault is promoted to its full severity, so the admin knows it may still resolve on its own shortly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.15 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.15.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc.1
Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.1 | cucsFaultObjects | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1 | cucsFaultTable | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1 | cucsFaultEntry | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1.15 | cucsFaultLc | CISCO-UNIFIED-COMPUTING-FAULT-MIB |