CISCO-UNIFIED-COMPUTING-FAULT-MIB :: cucsFaultLc

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FAULT-MIBcucsFaultLc

cucsFaultLc

Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc

OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.15

Node type: OBJECT-TYPE

Type: CucsConditionLifecycle

Access: read-only

Description: Cisco UCS fault:Inst:lc managed object property

What is cucsFaultLc?

This reports the lifecycle stage of this fault - for example whether it is currently active/raising, soaking, or in the process of clearing. This tells an admin whether a fault that appears in the list is a live, currently-true condition or one that's already in the process of aging out per the fault policy's clear/retention settings, which changes whether immediate action is warranted. A lifecycle value of soaking means the underlying condition has to persist for the soak interval configured in the fault policy before this fault is promoted to its full severity, so the admin knows it may still resolve on its own shortly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.15
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.15.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc.1

Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultLc OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.1cucsFaultObjectsCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1cucsFaultTableCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1cucsFaultEntryCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1.15cucsFaultLcCISCO-UNIFIED-COMPUTING-FAULT-MIB