CISCO-UNIFIED-COMPUTING-FAULT-MIB :: cucsFaultDescription

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-FAULT-MIBcucsFaultDescription

cucsFaultDescription

Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription

OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.11

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS fault:Inst:descr managed object property

What is cucsFaultDescription?

This is the free-text description of this specific fault, explaining in words what condition triggered it. This is the field an admin actually reads first when a fault fires, since it typically spells out the specific problem, such as power supply removed or link down, in plain language rather than requiring lookup of the numeric fault code. A description reading 'Power Supply Redundancy is not restored in Chassis 1' would immediately tell the admin what to physically go check.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.11
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.11.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription.1

Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.1cucsFaultObjectsCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1cucsFaultTableCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1cucsFaultEntryCISCO-UNIFIED-COMPUTING-FAULT-MIB
1.3.6.1.4.1.9.9.719.1.1.1.1.11cucsFaultDescriptionCISCO-UNIFIED-COMPUTING-FAULT-MIB