All MIBs › CISCO-UNIFIED-COMPUTING-FAULT-MIB › cucsFaultDescription
cucsFaultDescription
Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription
OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.11
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS fault:Inst:descr managed object property
What is cucsFaultDescription?
This is the free-text description of this specific fault, explaining in words what condition triggered it. This is the field an admin actually reads first when a fault fires, since it typically spells out the specific problem, such as power supply removed or link down, in plain language rather than requiring lookup of the numeric fault code. A description reading 'Power Supply Redundancy is not restored in Chassis 1' would immediately tell the admin what to physically go check.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.11 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.11.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription.1
Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultDescription OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.1 | cucsFaultObjects | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1 | cucsFaultTable | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1 | cucsFaultEntry | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1.11 | cucsFaultDescription | CISCO-UNIFIED-COMPUTING-FAULT-MIB |