All MIBs › CISCO-UNIFIED-COMPUTING-FAULT-MIB › cucsFaultAffectedObjectId
cucsFaultAffectedObjectId
Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAffectedObjectId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.4
Node type: OBJECT-TYPE
Type: RowPointer
Access: read-only
Description: Cisco UCS fault:Inst:affectedObjectId managed object property
What is cucsFaultAffectedObjectId?
This is a row pointer to the specific table entry of the object this fault was raised against. This gives an admin's automation a direct, indexable link from the fault to the exact row representing the affected object in whatever table it lives in, useful for programmatically joining fault data with the affected object's own current state. For a fault raised against a specific power supply, this pointer would resolve to that power supply's own row in its managed-object table.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.4 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAffectedObjectId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.4.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAffectedObjectId.1
Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAffectedObjectId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.1 | cucsFaultObjects | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1 | cucsFaultTable | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1 | cucsFaultEntry | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1.4 | cucsFaultAffectedObjectId | CISCO-UNIFIED-COMPUTING-FAULT-MIB |