All MIBs › CISCO-UNIFIED-COMPUTING-FAULT-MIB › cucsFaultAck
cucsFaultAck
Module: CISCO-UNIFIED-COMPUTING-FAULT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAck
OID (numeric): 1.3.6.1.4.1.9.9.719.1.1.1.1.6
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: Cisco UCS fault:Inst:ack managed object property
What is cucsFaultAck?
This boolean reports whether an administrator has acknowledged this specific fault. This is the field a NOC dashboard uses to distinguish faults that have already been triaged by someone, acknowledged and being worked, from faults nobody has looked at yet, which matters for on-call escalation policies that only page on unacknowledged faults. A value of false on a high-severity fault that's been open for an hour would likely trigger an escalation, whereas true would suppress further paging on that specific fault since someone's already handling it.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.6 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAck
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.1.1.1.6.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAck.1
Start monitoring Cisco UCS blade servers and chassis (fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-FAULT-MIB::cucsFaultAck OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis (fault management) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.1 | cucsFaultObjects | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1 | cucsFaultTable | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1 | cucsFaultEntry | CISCO-UNIFIED-COMPUTING-FAULT-MIB |
| 1.3.6.1.4.1.9.9.719.1.1.1.1.6 | cucsFaultAck | CISCO-UNIFIED-COMPUTING-FAULT-MIB |