CISCO-UNIFIED-COMPUTING-DOMAIN-MIB :: cucsDomainNetworkFeatureRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-DOMAIN-MIBcucsDomainNetworkFeatureRn

cucsDomainNetworkFeatureRn

Module: CISCO-UNIFIED-COMPUTING-DOMAIN-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-DOMAIN-MIB::cucsDomainNetworkFeatureRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.74.3.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS domain:NetworkFeature:rn managed object property

What is cucsDomainNetworkFeatureRn?

This is the object's relative name (Rn) — just the last path segment of its Dn, the piece this NetworkFeature instance contributes to its own address within the MIT tree. It records whether a specific fabric-interconnect capability — such as end-host mode or a particular switching mode — is available on this domain's fabric interconnects, which matters when deciding whether a given uplink design is even supported. For this kind of object the Rn is typically built from the same identifying value as its Dn's final segment, e.g. the tail end of `sys/switch-A/network-feature-end-host-mode`, so two sibling instances never end up with colliding addresses under the same parent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.74.3.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-DOMAIN-MIB::cucsDomainNetworkFeatureRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.74.3.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-DOMAIN-MIB::cucsDomainNetworkFeatureRn.1

Start monitoring Cisco UCS fabric interconnects and blade/rack chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-DOMAIN-MIB::cucsDomainNetworkFeatureRn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects and blade/rack chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.74cucsDomainObjectsCISCO-UNIFIED-COMPUTING-DOMAIN-MIB
1.3.6.1.4.1.9.9.719.1.74.3cucsDomainNetworkFeatureTableCISCO-UNIFIED-COMPUTING-DOMAIN-MIB
1.3.6.1.4.1.9.9.719.1.74.3.1cucsDomainNetworkFeatureEntryCISCO-UNIFIED-COMPUTING-DOMAIN-MIB
1.3.6.1.4.1.9.9.719.1.74.3.1.3cucsDomainNetworkFeatureRnCISCO-UNIFIED-COMPUTING-DOMAIN-MIB