CISCO-SCSI-FLOW-MIB :: ciscoScsiFlowWrAccIntrCfgStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-SCSI-FLOW-MIBciscoScsiFlowWrAccIntrCfgStatus

ciscoScsiFlowWrAccIntrCfgStatus

Module: CISCO-SCSI-FLOW-MIB

OID (symbolic): CISCO-SCSI-FLOW-MIB::ciscoScsiFlowWrAccIntrCfgStatus

OID (numeric): 1.3.6.1.4.1.9.9.447.1.3.1.1.2

Node type: OBJECT-TYPE

Type: CSFlowCfgReasonCode

Access: read-only

Description: The initiator configuration status for write-acceleration feature for this flow.

What is ciscoScsiFlowWrAccIntrCfgStatus?

This object narrows the write-acceleration configuration status down specifically to the initiator side of the flow, complementing the overall status in ciscoScsiFlowWrAccCfgStatus. An admin diagnosing why write-acceleration failed to apply can check this specific field to determine whether the problem is on the initiator's line card/hardware rather than the target side, directing the troubleshooting effort to the correct end of the path. If this initiator-side status shows a failure while the target-side status is fine, the admin knows to focus on the host-facing line card's capability or configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.447.1.3.1.1.2
snmpwalk -v2c -c public <target> CISCO-SCSI-FLOW-MIB::ciscoScsiFlowWrAccIntrCfgStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.447.1.3.1.1.2.1
snmpget -v2c -c public <target> CISCO-SCSI-FLOW-MIB::ciscoScsiFlowWrAccIntrCfgStatus.1

Start monitoring Cisco MDS SAN switches/directors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-SCSI-FLOW-MIB::ciscoScsiFlowWrAccIntrCfgStatus OID value, configure state conditions and alerts, and monitor any Cisco MDS SAN switches/directors from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.447ciscoScsiFlowMIBCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1ciscoScsiFlowMIBObjectsCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.3csfFeatureStatusCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.3.1ciscoScsiFlowWrAccStatusTableCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.3.1.1ciscoScsiFlowWrAccStatusEntryCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.3.1.1.2ciscoScsiFlowWrAccIntrCfgStatusCISCO-SCSI-FLOW-MIB