CISCO-SCSI-FLOW-MIB :: ciscoScsiFlowTargetVsan

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-SCSI-FLOW-MIBciscoScsiFlowTargetVsan

ciscoScsiFlowTargetVsan

Module: CISCO-SCSI-FLOW-MIB

OID (symbolic): CISCO-SCSI-FLOW-MIB::ciscoScsiFlowTargetVsan

OID (numeric): 1.3.6.1.4.1.9.9.447.1.1.2.1.5

Node type: OBJECT-TYPE

Type: VsanIndex

Access: read-write

Description: The VSAN ID of the target on which the flow is configured.

What is ciscoScsiFlowTargetVsan?

This object specifies the VSAN that the flow's target resides on, mirroring ciscoScsiFlowIntrVsan for the storage side of the connection. An admin setting up a flow across VSANs (or confirming both ends sit in the expected VSAN) checks this value to make sure the target storage port is actually reachable within the fabric topology assumed by the flow configuration. If this reads a different VSAN number than the initiator's VSAN, that would flag an inter-VSAN routing setup the admin needs to verify is properly configured.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.447.1.1.2.1.5
snmpwalk -v2c -c public <target> CISCO-SCSI-FLOW-MIB::ciscoScsiFlowTargetVsan

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.447.1.1.2.1.5.1
snmpget -v2c -c public <target> CISCO-SCSI-FLOW-MIB::ciscoScsiFlowTargetVsan.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.447.1.1.2.1.5.1 s <value>

Start monitoring Cisco MDS SAN switches/directors with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-SCSI-FLOW-MIB::ciscoScsiFlowTargetVsan OID value, configure state conditions and alerts, and monitor any Cisco MDS SAN switches/directors from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.447ciscoScsiFlowMIBCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1ciscoScsiFlowMIBObjectsCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.1csfConfigurationCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.1.2ciscoScsiFlowTableCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.1.2.1ciscoScsiFlowEntryCISCO-SCSI-FLOW-MIB
1.3.6.1.4.1.9.9.447.1.1.2.1.5ciscoScsiFlowTargetVsanCISCO-SCSI-FLOW-MIB