CISCO-OTV-MIB :: cotvSiteVlanState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-OTV-MIBcotvSiteVlanState

cotvSiteVlanState

Module: CISCO-OTV-MIB

OID (symbolic): CISCO-OTV-MIB::cotvSiteVlanState

OID (numeric): 1.3.6.1.4.1.9.9.810.1.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object indicates the state of OTV site VLAN.

'up' - OTV site VLAN is up

'down' - OTV site VLAN is down

What is cotvSiteVlanState?

Reports whether the configured OTV site VLAN on this device is currently up or down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.810.1.1.1.4
snmpwalk -v2c -c public <target> CISCO-OTV-MIB::cotvSiteVlanState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.810.1.1.1.4.1
snmpget -v2c -c public <target> CISCO-OTV-MIB::cotvSiteVlanState.1

Start monitoring Cisco data center switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-OTV-MIB::cotvSiteVlanState OID value, configure state conditions and alerts, and monitor any Cisco data center switches from a single console.

How to Use in IPNetwork Monitor

Select a Cisco data center switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cotvSiteVlanState into the Find box to locate it in the OID tree, then select it and click OK. This object indicates the state of OTV site VLAN. 'up' - OTV site VLAN is up 'down' - OTV site VLAN is down. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'up', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.810ciscoOtvMIBCISCO-OTV-MIB
1.3.6.1.4.1.9.9.810.1ciscoOtvMIBObjectsCISCO-OTV-MIB
1.3.6.1.4.1.9.9.810.1.1cotvGlobalObjectsCISCO-OTV-MIB
1.3.6.1.4.1.9.9.810.1.1.1cotvSiteObjectsCISCO-OTV-MIB
1.3.6.1.4.1.9.9.810.1.1.1.4cotvSiteVlanStateCISCO-OTV-MIB