CISCO-IETF-ISNS-MGMT-MIB :: cIsnsClntInstScndryDiscMthd

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-IETF-ISNS-MGMT-MIBcIsnsClntInstScndryDiscMthd

cIsnsClntInstScndryDiscMthd

Module: CISCO-IETF-ISNS-MGMT-MIB

OID (symbolic): CISCO-IETF-ISNS-MGMT-MIB::cIsnsClntInstScndryDiscMthd

OID (numeric): 1.3.6.1.4.1.9.10.116.1.2.1.1.12

Node type: OBJECT-TYPE

Type: CIsnsSrvrDscvryMthdId

Access: read-write

Description: Indicates the secondary discovery methods enabled on this iSNS Client instance. This allows secondary discovery methods, which are used by a client only if the primary method does not locate an iSNS Server, to be configured. For example, DHCP may be the primary discovery method, and configured-server-list may be a secondary discovery method. Multiple discovery methods in the bitmap may be designated as secondary discovery methods. If this is the case, then the order they are used is determined by the client. The primary discovery method should not be listed as a secondary discovery method. If no secondary discovery methods have been configured, then no bits are enabled. All secondary server methods will be attempted.

What is cIsnsClntInstScndryDiscMthd?

Configures the secondary discovery method(s) this iSNS client falls back to if the primary discovery method fails to locate an iSNS Server.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.10.116.1.2.1.1.12
snmpwalk -v2c -c public <target> CISCO-IETF-ISNS-MGMT-MIB::cIsnsClntInstScndryDiscMthd

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.10.116.1.2.1.1.12.1
snmpget -v2c -c public <target> CISCO-IETF-ISNS-MGMT-MIB::cIsnsClntInstScndryDiscMthd.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.10.116.1.2.1.1.12.1 s <value>

Start monitoring Cisco MDS storage switch / IP-storage gateway (iSNS server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-IETF-ISNS-MGMT-MIB::cIsnsClntInstScndryDiscMthd OID value, configure state conditions and alerts, and monitor any Cisco MDS storage switch / IP-storage gateway (iSNS server) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.10ciscoExperimentCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.10.116ciscoIetfIsnsMgmtMIBCISCO-IETF-ISNS-MGMT-MIB
1.3.6.1.4.1.9.10.116.1cIsnsObjCISCO-IETF-ISNS-MGMT-MIB
1.3.6.1.4.1.9.10.116.1.2cIsnsClntInfoCISCO-IETF-ISNS-MGMT-MIB
1.3.6.1.4.1.9.10.116.1.2.1cIsnsClntInstTableCISCO-IETF-ISNS-MGMT-MIB
1.3.6.1.4.1.9.10.116.1.2.1.1cIsnsClntInstEntryCISCO-IETF-ISNS-MGMT-MIB
1.3.6.1.4.1.9.10.116.1.2.1.1.12cIsnsClntInstScndryDiscMthdCISCO-IETF-ISNS-MGMT-MIB