All MIBs › CISCO-FIREPOWER-STORAGE-MIB › cfprStorageFlexFlashControllerPciAddr
cfprStorageFlexFlashControllerPciAddr
Module: CISCO-FIREPOWER-STORAGE-MIB
OID (symbolic): CISCO-FIREPOWER-STORAGE-MIB::cfprStorageFlexFlashControllerPciAddr
OID (numeric): 1.3.6.1.4.1.9.9.826.1.74.14.1.31
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco Firepower storage:FlexFlashController:pciAddr managed object property
What is cfprStorageFlexFlashControllerPciAddr?
Reports the PCI address on the system bus where the FlexFlash controller is attached, useful for hardware identification.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.74.14.1.31 snmpwalk -v2c -c public <target> CISCO-FIREPOWER-STORAGE-MIB::cfprStorageFlexFlashControllerPciAddr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.74.14.1.31.1 snmpget -v2c -c public <target> CISCO-FIREPOWER-STORAGE-MIB::cfprStorageFlexFlashControllerPciAddr.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cfprStorageFlexFlashControllerPciAddr.1
Start monitoring Cisco Firepower security appliance (9300/4100 series) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FIREPOWER-STORAGE-MIB::cfprStorageFlexFlashControllerPciAddr OID value, configure state conditions and alerts, and monitor any Cisco Firepower security appliance (9300/4100 series) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.826 | ciscoFirepowerMIB | CISCO-FIREPOWER-MIB |
| 1.3.6.1.4.1.9.9.826.1 | ciscoFirepowerMIBObjects | CISCO-FIREPOWER-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.826.1.74 | cfprStorageObjects | CISCO-FIREPOWER-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.826.1.74.14 | cfprStorageFlexFlashControllerTable | CISCO-FIREPOWER-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.826.1.74.14.1 | cfprStorageFlexFlashControllerEntry | CISCO-FIREPOWER-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.826.1.74.14.1.31 | cfprStorageFlexFlashControllerPciAddr | CISCO-FIREPOWER-STORAGE-MIB |