CISCO-FC-FE-MIB :: fcIfLinkFailures

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-FC-FE-MIBfcIfLinkFailures

fcIfLinkFailures

Module: CISCO-FC-FE-MIB

OID (symbolic): CISCO-FC-FE-MIB::fcIfLinkFailures

OID (numeric): 1.3.6.1.4.1.9.9.289.1.2.1.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of link failures detected by the FC-Port.

What is fcIfLinkFailures?

A read-only counter tracking the number of physical link failures detected on a Fibre Channel port, useful for spotting unstable cabling or transceiver issues.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.2.1.1.1
snmpwalk -v2c -c public <target> CISCO-FC-FE-MIB::fcIfLinkFailures

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.2.1.1.1.1
snmpget -v2c -c public <target> CISCO-FC-FE-MIB::fcIfLinkFailures.1

Start monitoring Cisco MDS Fibre Channel SAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FC-FE-MIB::fcIfLinkFailures OID value, configure state conditions and alerts, and monitor any Cisco MDS Fibre Channel SAN switches from a single console.

How to Use in IPNetwork Monitor

Select a Cisco MDS Fibre Channel SAN switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type fcIfLinkFailures into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of link failures detected by the FC-Port. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.289ciscoFcFeMIBCISCO-FC-FE-MIB
1.3.6.1.4.1.9.9.289.1ciscoFcFeObjectsCISCO-FC-FE-MIB
1.3.6.1.4.1.9.9.289.1.2cffFcFeStatisticsCISCO-FC-FE-MIB
1.3.6.1.4.1.9.9.289.1.2.1fcIfErrorTableCISCO-FC-FE-MIB
1.3.6.1.4.1.9.9.289.1.2.1.1fcIfErrorEntryCISCO-FC-FE-MIB
1.3.6.1.4.1.9.9.289.1.2.1.1.1fcIfLinkFailuresCISCO-FC-FE-MIB