All MIBs › CISCO-FC-FE-MIB › fcIfAdminRxBbCredit
fcIfAdminRxBbCredit
Module: CISCO-FC-FE-MIB
OID (symbolic): CISCO-FC-FE-MIB::fcIfAdminRxBbCredit
OID (numeric): 1.3.6.1.4.1.9.9.289.1.1.2.1.24
Node type: OBJECT-TYPE
Type: FcBbCredit
Access: read-write
Description: The receive buffer-to-buffer credits configured for this port. If the value configured is zero, then the value of the object fcIfCapOsmRxBbCreditDefault or fcIfCapFrmRxBbCreditDefault is used if the port is operating in Fx mode. Value of fcIfCapOsmRxBbCreditDefault is used if fcIfPortRateMode is 'shared'. Value of fcIfCapFrmRxBbCreditDefault is used if fcIfPortRateMode is 'dedicated'. Similarly, if the port is operating in inter switch link (ISL) mode then the value of the object fcIfCapOsmISLRxBbCreditDefault or fcIfCapFrmISLRxBbCreditDefault is used. Value of fcIfCapOsmISLRxBbCreditDefault is used if fcIfPortRateMode is 'shared'. Value of fcIfCapFrmISLRxBbCreditDefault is used if fcIfPortRateMode is 'dedicated'. If a non-zero value is configured for this object then, if the values configured for fcIfAdminRxBbCreditModeISL and fcIfAdminRxBbCreditModeFx is zero, then the value of this object is used for the port operating in either Fx or ISL port mode. But if fcIfAdminRxBbCreditModeISL is configured with a valid value, then the value of fcIfAdminRxBbCreditModeISL object is used instead of this value, if the port is operating in ISL port mode. Similarly, if the values configured for fcIfAdminRxBbCreditModeFx is valid, then the value of fcIfAdminRxBbCreditModeFx object is used instead of this value, if the port is operating in Fx mode. If this object is set to non-zero value then objects fcIfAdminRxBbCreditModeISL and fcIfAdminRxBbCreditModeFx are set to zero at that time. But later the objects fcIfAdminRxBbCreditModeISL and fcIfAdminRxBbCreditModeFx can be configured to non-zero values even if this object present value is non-zero.
NOTE: The value of this object is not used if cfcFeatureCtrlIndex object is configured with a value of 'extenedCredit' and fcIfAdminRxBbCreditExtended object is configured.
What is fcIfAdminRxBbCredit?
A configurable setting for the number of receive buffer-to-buffer credits allocated to the port; a value of zero causes a default credit value to be used depending on the port's operating mode.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.24 snmpwalk -v2c -c public <target> CISCO-FC-FE-MIB::fcIfAdminRxBbCredit
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.24.1 snmpget -v2c -c public <target> CISCO-FC-FE-MIB::fcIfAdminRxBbCredit.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.24.1 s <value>
Start monitoring Cisco MDS Fibre Channel SAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FC-FE-MIB::fcIfAdminRxBbCredit OID value, configure state conditions and alerts, and monitor any Cisco MDS Fibre Channel SAN switches from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.289 | ciscoFcFeMIB | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1 | ciscoFcFeObjects | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1 | cffFcFeConfig | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2 | fcIfTable | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2.1 | fcIfEntry | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2.1.24 | fcIfAdminRxBbCredit | CISCO-FC-FE-MIB |