All MIBs › CISCO-FC-FE-MIB › fcIfAdminBbScnMode
fcIfAdminBbScnMode
Module: CISCO-FC-FE-MIB
OID (symbolic): CISCO-FC-FE-MIB::fcIfAdminBbScnMode
OID (numeric): 1.3.6.1.4.1.9.9.289.1.1.2.1.39
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: The Buffer-to-buffer State Change Number (BB_SC_N) field (word 1, bits 15-12) specifies the Buffer-to-buffer State Change Number. It indicates that the sender of the PLOGI or FLOGI frame is requesting 2 power BB_SC_N number of frames to be sent between two consecutive BB_SCs primitives, and 2 power BB_SC_N number of R_RDY primitives to be sent between two consecutive BB_SCr primitives. If 'true', the BB_SC_N mode is enabled. If 'false', the BB_SC_N mode is disabled.
What is fcIfAdminBbScnMode?
This read-write setting configures the Buffer-to-buffer State Change Number (BB_SC_N) mode, which determines how many frames (as a power of 2) can be sent between credit resynchronization events during login negotiation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.39 snmpwalk -v2c -c public <target> CISCO-FC-FE-MIB::fcIfAdminBbScnMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.39.1 snmpget -v2c -c public <target> CISCO-FC-FE-MIB::fcIfAdminBbScnMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.289.1.1.2.1.39.1 s <value>
Start monitoring Cisco MDS Fibre Channel SAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FC-FE-MIB::fcIfAdminBbScnMode OID value, configure state conditions and alerts, and monitor any Cisco MDS Fibre Channel SAN switches from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.289 | ciscoFcFeMIB | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1 | ciscoFcFeObjects | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1 | cffFcFeConfig | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2 | fcIfTable | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2.1 | fcIfEntry | CISCO-FC-FE-MIB |
| 1.3.6.1.4.1.9.9.289.1.1.2.1.39 | fcIfAdminBbScnMode | CISCO-FC-FE-MIB |