CISCO-DIST-DIRECTOR-MIB :: cddServerPortDownCertainty

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-DIST-DIRECTOR-MIBcddServerPortDownCertainty

cddServerPortDownCertainty

Module: CISCO-DIST-DIRECTOR-MIB

OID (symbolic): CISCO-DIST-DIRECTOR-MIB::cddServerPortDownCertainty

OID (numeric): 1.3.6.1.4.1.9.9.197.1.3.2.1.10

Node type: OBJECT-TYPE

Type: Gauge

Access: read-only

Description: Indicates the percentage of the downed port service possibility. This value is applicable only if the value of cddServerPortStatus is 'down'.

What is cddServerPortDownCertainty?

This object reports the percentage certainty that a specific server port's service is actually down, applicable only when cddServerPortStatus for that port shows down. Because availability checks can produce false positives, like a transient network blip, this certainty percentage gives an admin a sense of how confident the Director is in a down determination before acting on it, rather than treating every down status as absolute. A port reporting down with only 20% certainty might just be a single missed health check, while one showing 95% certainty after repeated failed checks is a much stronger signal the service is genuinely unavailable and should be pulled from rotation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.197.1.3.2.1.10
snmpwalk -v2c -c public <target> CISCO-DIST-DIRECTOR-MIB::cddServerPortDownCertainty

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.197.1.3.2.1.10.1
snmpget -v2c -c public <target> CISCO-DIST-DIRECTOR-MIB::cddServerPortDownCertainty.1

Start monitoring Cisco DistributedDirector appliances (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-DIST-DIRECTOR-MIB::cddServerPortDownCertainty OID value, configure state conditions and alerts, and monitor any Cisco DistributedDirector appliances (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.197ciscoDistDirMIBCISCO-DIST-DIRECTOR-MIB
1.3.6.1.4.1.9.9.197.1ciscoDistDirMIBObjectsCISCO-DIST-DIRECTOR-MIB
1.3.6.1.4.1.9.9.197.1.3cddServerCISCO-DIST-DIRECTOR-MIB
1.3.6.1.4.1.9.9.197.1.3.2cddServerPortTableCISCO-DIST-DIRECTOR-MIB
1.3.6.1.4.1.9.9.197.1.3.2.1cddServerPortEntryCISCO-DIST-DIRECTOR-MIB
1.3.6.1.4.1.9.9.197.1.3.2.1.10cddServerPortDownCertaintyCISCO-DIST-DIRECTOR-MIB