All MIBs › CISCO-CATOS-ACL-QOS-MIB › caqIfArpInspShutdownThreshold
caqIfArpInspShutdownThreshold
Module: CISCO-CATOS-ACL-QOS-MIB
OID (symbolic): CISCO-CATOS-ACL-QOS-MIB::caqIfArpInspShutdownThreshold
OID (numeric): 1.3.6.1.4.1.9.9.179.1.8.11.1.2
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: Indicates the threshold value where the interface will be shutdown if traffic rate subjected to ARP Inspection is greater than this threshold value. If the value of this object is 0, no ARP traffic rate limit is applied for shutting down the interface.
What is caqIfArpInspShutdownThreshold?
This read-write value sets the per-interface ARP traffic rate threshold that, when exceeded, causes the interface to be shut down; a value of 0 disables this shutdown-based rate limiting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.179.1.8.11.1.2 snmpwalk -v2c -c public <target> CISCO-CATOS-ACL-QOS-MIB::caqIfArpInspShutdownThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.179.1.8.11.1.2.1 snmpget -v2c -c public <target> CISCO-CATOS-ACL-QOS-MIB::caqIfArpInspShutdownThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.179.1.8.11.1.2.1 i <value>
Start monitoring Cisco Catalyst 5000/6000 series switches running CatOS (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-CATOS-ACL-QOS-MIB::caqIfArpInspShutdownThreshold OID value, configure state conditions and alerts, and monitor any Cisco Catalyst 5000/6000 series switches running CatOS (legacy) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.179 | ciscoCatOSAclQosMIB | CISCO-CATOS-ACL-QOS-MIB |
| 1.3.6.1.4.1.9.9.179.1 | ciscoCatOSAclQosMIBObjects | CISCO-CATOS-ACL-QOS-MIB |
| 1.3.6.1.4.1.9.9.179.1.8 | caqArpInspObjects | CISCO-CATOS-ACL-QOS-MIB |
| 1.3.6.1.4.1.9.9.179.1.8.11 | caqIfArpInspConfigTable | CISCO-CATOS-ACL-QOS-MIB |
| 1.3.6.1.4.1.9.9.179.1.8.11.1 | caqIfArpInspConfigEntry | CISCO-CATOS-ACL-QOS-MIB |
| 1.3.6.1.4.1.9.9.179.1.8.11.1.2 | caqIfArpInspShutdownThreshold | CISCO-CATOS-ACL-QOS-MIB |