Module: CIENA-CES-OAM-MIB

OID (symbolic): CIENA-CES-OAM-MIB::cienaCesOamErrFrameWindow

OID (numeric): 1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: The amount of time (in 100ms increments) over which the threshold is defined. The default value is 10 (1 second).

If cienaCesOamErrFrameThreshold frame errors occur within a window of cienaCesOamErrFrameWindow seconds (measured in tenths of seconds), an Event Notification OAMPDU should be generated with an Errored Frame Event TLV indicating the threshold has been crossed in this window.

What is cienaCesOamErrFrameWindow?

This read-only Unsigned32 (10 to 600, in tenths of a second) defines the time window over which the errored-frame threshold is evaluated, per its description, defaulting to 10 tenths, i.e., one full second. Unlike the frame-count-based errFramePeriod window, this window is purely time-based, so its real-time duration doesn't change with link speed, making the errored-frame event a more speed-independent way to gauge a sustained rate of bit errors. An engineer comparing error-rate alarms across mixed-speed ports in the same chassis would find this time-based window more directly comparable across a 1G and a 10G port than the frame-count-based period window.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5
snmpwalk -v2c -c public <target> CIENA-CES-OAM-MIB::cienaCesOamErrFrameWindow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5.1
snmpget -v2c -c public <target> CIENA-CES-OAM-MIB::cienaCesOamErrFrameWindow.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-OAM-MIB::cienaCesOamErrFrameWindow OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.5cienaCesOamMibModuleCIENA-CES-OAM-MIB
1.3.6.1.4.1.1271.2.3.5.1cienaCesOamMIBCIENA-CES-OAM-MIB
1.3.6.1.4.1.1271.2.3.5.1.1cienaCesOamStatisticsCIENA-CES-OAM-MIB
1.3.6.1.4.1.1271.2.3.5.1.1.8cienaCesOamEventConfigTableCIENA-CES-OAM-MIB
1.3.6.1.4.1.1271.2.3.5.1.1.8.1cienaCesOamEventConfigEntryCIENA-CES-OAM-MIB
1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5cienaCesOamErrFrameWindowCIENA-CES-OAM-MIB