CIENA-CES-ICL-MIB :: cienaCesIclRxTimeout

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-ICL-MIB › cienaCesIclRxTimeout

cienaCesIclRxTimeout

Module: CIENA-CES-ICL-MIB

OID (symbolic): CIENA-CES-ICL-MIB::cienaCesIclRxTimeout

OID (numeric): 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object specifies if Rx timeout fault is set on the ICL

What is cienaCesIclRxTimeout?

This flags whether the device has stopped receiving expected heartbeat frames from the peer chassis over the ICL within the expected time window. A yes(2) reading is a strong signal that the physical link or the peer chassis itself has gone silent, which an admin would treat as an urgent failover trigger for the redundant chassis pair. In practice this flag typically flips to yes(2) at the same time cienaCesIclStatus transitions to failed(3) or down(4).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.14
snmpwalk -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclRxTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.14.1
snmpget -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclRxTimeout.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cienaCesIclRxTimeout.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ICL-MIB::cienaCesIclRxTimeout OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.32cienaCesIclMIBCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1cienaCesIclMIBObjectsCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1cienaCesIclCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1cienaCesIclTableCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1cienaCesIclEntryCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1.14cienaCesIclRxTimeoutCIENA-CES-ICL-MIB