All MIBs › CIENA-CES-ICL-MIB › cienaCesIclRxConfigMismatch
cienaCesIclRxConfigMismatch
Module: CIENA-CES-ICL-MIB
OID (symbolic): CIENA-CES-ICL-MIB::cienaCesIclRxConfigMismatch
OID (numeric): 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.26
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: This object specifies the number of ICL config mismatch frames received.
What is cienaCesIclRxConfigMismatch?
This counts frames received over the ICL that indicate the peer chassis is configured differently than expected, for instance differing heartbeat intervals, ICL type, or other CICP parameters advertised in the frame. An admin seeing this counter increase after touching configuration on either chassis should suspect the change wasn't applied symmetrically on both sides of the ICL. For example, a jump in this counter right after upgrading one chassis's firmware would suggest a version-driven parameter mismatch between the two ends.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.26 snmpwalk -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclRxConfigMismatch
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.26.1 snmpget -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclRxConfigMismatch.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ICL-MIB::cienaCesIclRxConfigMismatch OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.32 | cienaCesIclMIB | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1 | cienaCesIclMIBObjects | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1 | cienaCesIcl | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1 | cienaCesIclTable | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1.1 | cienaCesIclEntry | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.26 | cienaCesIclRxConfigMismatch | CIENA-CES-ICL-MIB |