CIENA-CES-ICL-MIB :: cienaCesIclNumberFailures

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-ICL-MIB › cienaCesIclNumberFailures

cienaCesIclNumberFailures

Module: CIENA-CES-ICL-MIB

OID (symbolic): CIENA-CES-ICL-MIB::cienaCesIclNumberFailures

OID (numeric): 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.25

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object specifies the number of ICL failures.

What is cienaCesIclNumberFailures?

This tallies the total number of distinct failure events this inter-chassis link has experienced, giving a higher-level count of how many times it has gone down rather than a byte or frame counter. An admin comparing this count across the ICLs on a multi-chassis deployment can quickly spot which specific link is chronically unreliable and warrants a hardware or cabling swap rather than repeated software troubleshooting. A count of 12 failures in a month on one ICL versus 0 on a sibling link would clearly flag the problem link for physical inspection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.25
snmpwalk -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclNumberFailures

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.25.1
snmpget -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclNumberFailures.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ICL-MIB::cienaCesIclNumberFailures OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.32cienaCesIclMIBCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1cienaCesIclMIBObjectsCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1cienaCesIclCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1cienaCesIclTableCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1cienaCesIclEntryCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1.25cienaCesIclNumberFailuresCIENA-CES-ICL-MIB