CIENA-CES-ICL-MIB :: cienaCesIclHeartbeatInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-ICL-MIB › cienaCesIclHeartbeatInterval

cienaCesIclHeartbeatInterval

Module: CIENA-CES-ICL-MIB

OID (symbolic): CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval

OID (numeric): 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This object specifies the ICL heartbeat interval. The range is 1 to 30s and the default is 1s.

What is cienaCesIclHeartbeatInterval?

This sets how often the two chassis exchange ICL heartbeat frames to detect link failure, tunable from 1 to 30 seconds with a default of 1 second. A shorter interval, the 1-second default, gives faster failure detection at the cost of more control-plane overhead, so an admin might lengthen it slightly on a very busy chassis pair to reduce CPU load, trading off detection speed. Setting this to 5 would mean the chassis pair takes roughly five times as long to notice a lost heartbeat compared to the default.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16
snmpwalk -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16.1
snmpget -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.32cienaCesIclMIBCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1cienaCesIclMIBObjectsCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1cienaCesIclCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1cienaCesIclTableCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1cienaCesIclEntryCIENA-CES-ICL-MIB
1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16cienaCesIclHeartbeatIntervalCIENA-CES-ICL-MIB