All MIBs › CIENA-CES-ICL-MIB › cienaCesIclHeartbeatInterval
cienaCesIclHeartbeatInterval
Module: CIENA-CES-ICL-MIB
OID (symbolic): CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval
OID (numeric): 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This object specifies the ICL heartbeat interval. The range is 1 to 30s and the default is 1s.
What is cienaCesIclHeartbeatInterval?
This sets how often the two chassis exchange ICL heartbeat frames to detect link failure, tunable from 1 to 30 seconds with a default of 1 second. A shorter interval, the 1-second default, gives faster failure detection at the cost of more control-plane overhead, so an admin might lengthen it slightly on a very busy chassis pair to reduce CPU load, trading off detection speed. Setting this to 5 would mean the chassis pair takes roughly five times as long to notice a lost heartbeat compared to the default.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16 snmpwalk -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16.1 snmpget -v2c -c public <target> CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-ICL-MIB::cienaCesIclHeartbeatInterval OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.32 | cienaCesIclMIB | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1 | cienaCesIclMIBObjects | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1 | cienaCesIcl | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1 | cienaCesIclTable | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1.1 | cienaCesIclEntry | CIENA-CES-ICL-MIB |
| 1.3.6.1.4.1.1271.2.1.32.1.1.1.1.16 | cienaCesIclHeartbeatInterval | CIENA-CES-ICL-MIB |