CIENA-CES-DHCPV6-CLIENT-MIB :: cienaCesDhcpv6LdraMplsTrustMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-DHCPV6-CLIENT-MIBcienaCesDhcpv6LdraMplsTrustMode

cienaCesDhcpv6LdraMplsTrustMode

Module: CIENA-CES-DHCPV6-CLIENT-MIB

OID (symbolic): CIENA-CES-DHCPV6-CLIENT-MIB::cienaCesDhcpv6LdraMplsTrustMode

OID (numeric): 1.3.6.1.4.1.1271.2.1.30.1.2.14.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object is used to set the interface as client trusted, server trusted or not trusted.

Note that the client(1) mode is deprecated. That value will never be returned. Setting that value will set the mode to clientTrust(2) instead.

What is cienaCesDhcpv6LdraMplsTrustMode?

Sets the DHCPv6 trust role for this interface within the MPLS VS -- clientTrust, serverTrust, dualRoleTrust, or unTrust. Because MPLS-based services often carry aggregated traffic across a pseudowire rather than a single physical access port, this trust setting applies at the interface level for that pseudowire's traffic, which needs to be configured just as carefully as a VLAN access port to prevent rogue DHCPv6 servers from responding across the MPLS core. An interface carrying traffic toward the actual DHCPv6 server across the MPLS network would be set to serverTrust, while customer-facing interfaces on the same VS remain clientTrust.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.30.1.2.14.1.4
snmpwalk -v2c -c public <target> CIENA-CES-DHCPV6-CLIENT-MIB::cienaCesDhcpv6LdraMplsTrustMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.30.1.2.14.1.4.1
snmpget -v2c -c public <target> CIENA-CES-DHCPV6-CLIENT-MIB::cienaCesDhcpv6LdraMplsTrustMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1271.2.1.30.1.2.14.1.4.1 i <value>

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-DHCPV6-CLIENT-MIB::cienaCesDhcpv6LdraMplsTrustMode OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.30cienaCesDhcpv6ClientMIBCIENA-CES-DHCPV6-CLIENT-MIB
1.3.6.1.4.1.1271.2.1.30.1cienaCesDhcpv6ClientMIBObjectsCIENA-CES-DHCPV6-CLIENT-MIB
1.3.6.1.4.1.1271.2.1.30.1.2cienaCesDhcpv6RelayAgentCIENA-CES-DHCPV6-CLIENT-MIB
1.3.6.1.4.1.1271.2.1.30.1.2.14cienaCesDhcpv6LdraMplsTrustTableCIENA-CES-DHCPV6-CLIENT-MIB
1.3.6.1.4.1.1271.2.1.30.1.2.14.1cienaCesDhcpv6LdraMplsTrustEntryCIENA-CES-DHCPV6-CLIENT-MIB
1.3.6.1.4.1.1271.2.1.30.1.2.14.1.4cienaCesDhcpv6LdraMplsTrustModeCIENA-CES-DHCPV6-CLIENT-MIB