CIENA-CES-DATAPLANE-MIB :: cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-DATAPLANE-MIBcienaCesDpVirtualSwitchRlanL2CftL2ControlRcos

cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos

Module: CIENA-CES-DATAPLANE-MIB

OID (symbolic): CIENA-CES-DATAPLANE-MIB::cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos

OID (numeric): 1.3.6.1.4.1.1271.2.1.7.1.8.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object specifies the RCoS to use for control frames

An L2CF that is processed with an L2CFT disposition of

forwarding is flooded to all logical-interfaces in the

virtual switch/RLAN forwarding-domain, and is subject

to the same egress restrictions as normal data frames.

A frame that is classified as an Untagged L2CF is

forwarded by an L2CFT Instance using the RCoS value

specified by this object. The object does not apply

to a tagged L2CF frame that is classified as a

Transparent or L2PT form of a L2CF. Such frames are

given the same internal treatment as data frames

that are classified to the same logical-interface.

What is cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos?

This INTEGER sets the internal priority given to tunneled L2 control frames, like a customer's STP BPDUs, as they are flooded across the virtual switch's forwarding domain. Setting it too low risks those control frames being delayed or dropped under congestion, which could cause a customer's spanning tree to falsely detect a link failure. Setting this RCoS value high enough that tunneled STP BPDUs are not accidentally starved during heavy data congestion on the shared virtual switch is the practical concern.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.8.2.1.4
snmpwalk -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.8.2.1.4.1
snmpget -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos.1

Start monitoring Ciena CN5410 Carrier Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-DATAPLANE-MIB::cienaCesDpVirtualSwitchRlanL2CftL2ControlRcos OID value, configure state conditions and alerts, and monitor any Ciena CN5410 Carrier Ethernet Switch from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.7cienaCesDataplaneMIBCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1cienaCesDpMIBObjectsCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.8cienaCesDpVirtualSwitchCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.8.2cienaCesDpVirtualSwitchRlanTableCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.8.2.1cienaCesDpVirtualSwitchRlanEntryCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.8.2.1.4cienaCesDpVirtualSwitchRlanL2CftL2ControlRcosCIENA-CES-DATAPLANE-MIB