All MIBs › CIENA-CES-DATAPLANE-MIB › cienaCesDpTsQSchedulerTapPointPriority
cienaCesDpTsQSchedulerTapPointPriority
Module: CIENA-CES-DATAPLANE-MIB
OID (symbolic): CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerTapPointPriority
OID (numeric): 1.3.6.1.4.1.1271.2.1.7.1.5.5.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object specifies the priority of a tap point relative
to other tap points in the scheduler when the scheduler
algorithm is 'Strict Priority'.
What is cienaCesDpTsQSchedulerTapPointPriority?
This INTEGER is the actual number that determines drain order among sibling tap points under a Strict-Priority scheduler; a tap point with a higher priority value is always serviced first and can starve lower-priority siblings entirely under sustained congestion. This is a real risk admins must weigh when assigning this value, not just a cosmetic setting. Giving the voice tap point priority 7, the highest, guarantees it is always drained before a data tap point at priority 1, even if that starves the data traffic during a sustained voice-heavy period.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.5.5.2.1.2 snmpwalk -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerTapPointPriority
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.5.5.2.1.2.1 snmpget -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerTapPointPriority.1
Start monitoring Ciena CN5410 Carrier Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerTapPointPriority OID value, configure state conditions and alerts, and monitor any Ciena CN5410 Carrier Ethernet Switch from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.7 | cienaCesDataplaneMIB | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1 | cienaCesDpMIBObjects | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1.5 | cienaCesDpTsQ | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1.5.5 | cienaCesDpTsQSchedulerProfile | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1.5.5.2 | cienaCesDpTsQSchedulerTapPointTable | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1.5.5.2.1 | cienaCesDpTsQSchedulerTapPointEntry | CIENA-CES-DATAPLANE-MIB |
| 1.3.6.1.4.1.1271.2.1.7.1.5.5.2.1.2 | cienaCesDpTsQSchedulerTapPointPriority | CIENA-CES-DATAPLANE-MIB |