CIENA-CES-DATAPLANE-MIB :: cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-DATAPLANE-MIBcienaCesDpTsQSchedulerInstanceControlPlaneUsedCir

cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir

Module: CIENA-CES-DATAPLANE-MIB

OID (symbolic): CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir

OID (numeric): 1.3.6.1.4.1.1271.2.1.7.1.5.6.1.1.6

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This object specifies the control-plane-used-cir associated with the scheduler instance. It allows validation of dataplane CIR changes relative to control-plane usage

What is cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir?

This Unsigned32, in kilobits/sec, reports how much of this scheduler instance's CIR the device's own control-plane traffic, protocol packets and management traffic, is consuming; per the description it allows validation of dataplane CIR changes relative to control-plane usage. An admin checking this before shrinking the scheduler's dataplane CIR can avoid accidentally starving the control plane that shares the same scheduling hierarchy. Seeing a control-plane usage of 500 kbps, for example, warns the admin not to shrink this scheduler's total CIR below that floor without risking dropped protocol traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.5.6.1.1.6
snmpwalk -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.5.6.1.1.6.1
snmpget -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir.1

Start monitoring Ciena CN5410 Carrier Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-DATAPLANE-MIB::cienaCesDpTsQSchedulerInstanceControlPlaneUsedCir OID value, configure state conditions and alerts, and monitor any Ciena CN5410 Carrier Ethernet Switch from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.7cienaCesDataplaneMIBCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1cienaCesDpMIBObjectsCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.5cienaCesDpTsQCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.5.6cienaCesDpTsQSchedulerInstanceCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.5.6.1cienaCesDpTsQSchedulerInstanceTableCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.5.6.1.1cienaCesDpTsQSchedulerInstanceEntryCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.5.6.1.1.6cienaCesDpTsQSchedulerInstanceControlPlaneUsedCirCIENA-CES-DATAPLANE-MIB