CIENA-CES-DATAPLANE-MIB :: cienaCesDpL2CftProfileL2CftProtocolDisposition

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-DATAPLANE-MIBcienaCesDpL2CftProfileL2CftProtocolDisposition

cienaCesDpL2CftProfileL2CftProtocolDisposition

Module: CIENA-CES-DATAPLANE-MIB

OID (symbolic): CIENA-CES-DATAPLANE-MIB::cienaCesDpL2CftProfileL2CftProtocolDisposition

OID (numeric): 1.3.6.1.4.1.1271.2.1.7.1.14.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object specifies the L2CFT Profile L2CFT protocol action. There are 2 cases : - When 'cienaCesDpVirtualSwitchRlanL2CftStatus = disabled' or the protocol is not in the Disposition List, then an Untagged L2CF is handled using the ingress logical port's Default Disposition for the protocol, while Transparent and L2PT L2CF forms are handled as normal data frames. - When 'cienaCesDpVirtualSwitchRlanL2CftStatus = enabled' and L2CF protocol is in the Disposition List, the L2CF is either discarded or forwarded depending on the value of this object. An L2CF that is processed with an L2CFT disposition of 'forward' is flooded to all logical-interfaces in the virtual switch/RLAN forwarding-domain, and is subject to the same egress restrictions as normal data frames.

What is cienaCesDpL2CftProfileL2CftProtocolDisposition?

Specifies whether a given L2 control protocol is forwarded or discarded by this L2CFT profile, with the exact behavior depending on whether cienaCesDpVirtualSwitchRlanL2CftStatus is enabled or disabled for the RLAN it's applied to. Because the same disposition value is interpreted differently depending on that RLAN-level L2CFT status switch, an admin troubleshooting unexpected BPDU forwarding/discarding needs to check both settings together rather than assuming this object alone controls the outcome. Setting a protocol's disposition to discard(2) while L2CftStatus is enabled will actively drop that protocol's frames at ingress instead of tunneling them across the service.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.14.2.1.2
snmpwalk -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpL2CftProfileL2CftProtocolDisposition

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.7.1.14.2.1.2.1
snmpget -v2c -c public <target> CIENA-CES-DATAPLANE-MIB::cienaCesDpL2CftProfileL2CftProtocolDisposition.1

Start monitoring Ciena CN5410 Carrier Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-DATAPLANE-MIB::cienaCesDpL2CftProfileL2CftProtocolDisposition OID value, configure state conditions and alerts, and monitor any Ciena CN5410 Carrier Ethernet Switch from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.7cienaCesDataplaneMIBCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1cienaCesDpMIBObjectsCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.14cienaCesDpL2CftProfileCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.14.2cienaCesDpL2CftProfileL2CftProtocolTableCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.14.2.1cienaCesDpL2CftProfileL2CftProtocolEntryCIENA-CES-DATAPLANE-MIB
1.3.6.1.4.1.1271.2.1.7.1.14.2.1.2cienaCesDpL2CftProfileL2CftProtocolDispositionCIENA-CES-DATAPLANE-MIB