CIENA-CES-CFM-MIB :: cienaCesCfmServiceNumCCMForFault

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-CFM-MIBcienaCesCfmServiceNumCCMForFault

cienaCesCfmServiceNumCCMForFault

Module: CIENA-CES-CFM-MIB

OID (symbolic): CIENA-CES-CFM-MIB::cienaCesCfmServiceNumCCMForFault

OID (numeric): 1.3.6.1.4.1.1271.2.1.4.1.2.1.1.21

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This MIB object indicates the number of CCM frames that must go undelivered

for the PBB-TE tunnel before declaring the PBB-TE tunnel as operationally down.

This object is only applicable if cienaCesCfmServiceType is set to pbtTunnel, else this object

should be ignored.

What is cienaCesCfmServiceNumCCMForFault?

This sets the number of consecutive Continuity Check Messages that must go undelivered from a PBB-TE tunnel before the tunnel is declared operationally down, and the object explicitly states it only applies when cienaCesCfmServiceType is set to pbtTunnel; otherwise it should be ignored. An admin tunes this specifically for PBB-TE tunnel services to control how many missed heartbeats are tolerated before triggering a protection switchover, trading fault-detection speed against tolerance for occasional missed CCMs on a noisy path. For example, cienaCesCfmServiceNumCCMForFault set to 3 on a PBB-TE tunnel means three consecutive missed CCMs (rather than just one) are required before the tunnel is declared down and a protection path is invoked.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.4.1.2.1.1.21
snmpwalk -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmServiceNumCCMForFault

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.4.1.2.1.1.21.1
snmpget -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmServiceNumCCMForFault.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cienaCesCfmServiceNumCCMForFault.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CFM-MIB::cienaCesCfmServiceNumCCMForFault OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.4cienaCesCfmMIBCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.1.4.1.2cienaCesCfmServiceCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.1.4.1.2.1cienaCesCfmServiceTableCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.1.4.1.2.1.1cienaCesCfmServiceEntryCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.1.4.1.2.1.1.21cienaCesCfmServiceNumCCMForFaultCIENA-CES-CFM-MIB