CIENA-CES-CFM-MIB :: cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-CFM-MIBcienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply

cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply

Module: CIENA-CES-CFM-MIB

OID (symbolic): CIENA-CES-CFM-MIB::cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply

OID (numeric): 1.3.6.1.4.1.1271.2.3.4.1.3.1.1.54

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total number invalid of synthetic loss replies received by the CFM MEP.

What is cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply?

This counts SLRs received by this MEP that failed validation on this end, meaning this MEP's own synthetic-loss ratio calculation for its current test cannot fully trust every reply that technically arrived, and the remote responder's SLR generation for this specific relationship is worth checking if this counter keeps climbing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.4.1.3.1.1.54
snmpwalk -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.4.1.3.1.1.54.1
snmpget -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CFM-MIB::cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReply OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.4cienaCesCfmStatisticsMIBObjectsCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.3.4.1cienaCesCfmMIBObjectsCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.3.4.1.3cienaCesCfmMepStatsCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.3.4.1.3.1cienaCesCfmMepStatsTableCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.3.4.1.3.1.1cienaCesCfmMepStatsEntryCIENA-CES-CFM-MIB
1.3.6.1.4.1.1271.2.3.4.1.3.1.1.54cienaCesCfmMepStatsRxInvalidSyntheticLossMeasurementReplyCIENA-CES-CFM-MIB