All MIBs › CIENA-CES-CFM-MIB › cienaCesCfmMEPSignalDegradeTriggerMode
cienaCesCfmMEPSignalDegradeTriggerMode
Module: CIENA-CES-CFM-MIB
OID (symbolic): CIENA-CES-CFM-MIB::cienaCesCfmMEPSignalDegradeTriggerMode
OID (numeric): 1.3.6.1.4.1.1271.2.1.4.1.3.1.1.22
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object sets the signal degrade trigger mode on the mep. nearEnd: In this mode, near end frame loss shall be compared with cienaCesCfmSyntheticLossSessionSdSetThreshold and cienaCesCfmSyntheticLossSessionSdClearThreshold. nearFarEnd: In this mode, both near end and far end frame loss shall be compared with cienaCesCfmSyntheticLossSessionSdSetThreshold and cienaCesCfmSyntheticLossSessionSdClearThreshold.
What is cienaCesCfmMEPSignalDegradeTriggerMode?
This selects whether signal degrade detection on this MEP compares only near-end frame loss against the set/clear thresholds ('nearEnd' mode) or compares both near-end and far-end frame loss against those same thresholds ('nearFarEnd' mode), as explicitly described for the object. An admin picks nearFarEnd when the degradation being monitored for could plausibly originate on either side of the path (such as on a symmetric point-to-point circuit), while nearEnd suffices when only this MEP's own receive-side degradation is of concern. For example, setting cienaCesCfmMEPSignalDegradeTriggerMode to nearFarEnd on a circuit prone to intermittent issues on the remote end as well would ensure a far-end-only degradation still triggers the alarm, which nearEnd mode alone would miss.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.4.1.3.1.1.22 snmpwalk -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmMEPSignalDegradeTriggerMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.4.1.3.1.1.22.1 snmpget -v2c -c public <target> CIENA-CES-CFM-MIB::cienaCesCfmMEPSignalDegradeTriggerMode.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CFM-MIB::cienaCesCfmMEPSignalDegradeTriggerMode OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.4 | cienaCesCfmMIB | CIENA-CES-CFM-MIB |
| 1.3.6.1.4.1.1271.2.1.4.1.3 | cienaCesCfmMEP | CIENA-CES-CFM-MIB |
| 1.3.6.1.4.1.1271.2.1.4.1.3.1 | cienaCesCfmMEPTable | CIENA-CES-CFM-MIB |
| 1.3.6.1.4.1.1271.2.1.4.1.3.1.1 | cienaCesCfmMEPEntry | CIENA-CES-CFM-MIB |
| 1.3.6.1.4.1.1271.2.1.4.1.3.1.1.22 | cienaCesCfmMEPSignalDegradeTriggerMode | CIENA-CES-CFM-MIB |