CIENA-CES-BENCHMARK-MIB :: cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-BENCHMARK-MIBcienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow

cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow

Module: CIENA-CES-BENCHMARK-MIB

OID (symbolic): CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow

OID (numeric): 1.3.6.1.4.1.1271.2.1.39.1.1.14.1.9

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: When set to true, this indicates that the duplicate pkt counter has rolled over in hardware and therefore, cienaCesBenchmarkTestInstanceStatsRxDuplicatePkts might not be accurate.

What is cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow?

This TruthValue flags that the duplicate-packet counter (cienaCesBenchmarkTestInstanceStatsRxDuplicatePkts) has wrapped around in the hardware counter and can no longer be trusted as an accurate total for a long-running test. An admin needs this because Counter64 fields are normally assumed monotonic and reliable, but this flag warns that hardware-level rollover has actually happened here, so the duplicate count must be treated as a lower bound, not a true total. For example, on a multi-day soak test, seeing this flag flip to 'true' tells the engineer that the reported duplicate count understates reality and the test should probably be restarted with stats cleared if an exact figure is needed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.14.1.9
snmpwalk -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.14.1.9.1
snmpget -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflow OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.39cienaCesBenchmarkMIBCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1cienaCesBenchmarkMIBObjectsCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1cienaCesBenchmarkModuleCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.14cienaCesBenchmarkTestInstanceStatsTableCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.14.1cienaCesBenchmarkTestInstanceStatsEntryCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.14.1.9cienaCesBenchmarkTestInstanceStatsRxDuplicatePktsOverflowCIENA-CES-BENCHMARK-MIB