CIENA-CES-BENCHMARK-MIB :: cienaCesBenchmarkGenTestSessionFramelossResultsRate

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-BENCHMARK-MIBcienaCesBenchmarkGenTestSessionFramelossResultsRate

cienaCesBenchmarkGenTestSessionFramelossResultsRate

Module: CIENA-CES-BENCHMARK-MIB

OID (symbolic): CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsRate

OID (numeric): 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.9

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Rate in percent of line rate.

What is cienaCesBenchmarkGenTestSessionFramelossResultsRate?

This records the offered load, expressed as a percent of line rate, at which this frame-loss measurement was taken, since RFC2544 frame-loss testing is run at specific rate steps (commonly 100%, 90%, 80%, etc.) rather than at a single fixed load. An admin uses this to know exactly how hard the link was being pushed when a given loss percentage was recorded, because a small loss at 100% of line rate is a very different finding than the same loss at only 50% of line rate. For example, cienaCesBenchmarkGenTestSessionFramelossResultsRate = 100 paired with a 0% loss result demonstrates the port can sustain full line rate without dropping frames, which is a much stronger claim than the same 0% loss at a 50% rate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.9
snmpwalk -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.9.1
snmpget -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsRate.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cienaCesBenchmarkGenTestSessionFramelossResultsRate.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsRate OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.39cienaCesBenchmarkMIBCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1cienaCesBenchmarkMIBObjectsCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1cienaCesBenchmarkModuleCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16cienaCesBenchmarkGenTestSessionFramelossResultsTableCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16.1cienaCesBenchmarkGenTestSessionFramelossResultsEntryCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16.1.9cienaCesBenchmarkGenTestSessionFramelossResultsRateCIENA-CES-BENCHMARK-MIB