CIENA-CES-BENCHMARK-MIB :: cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-BENCHMARK-MIBcienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId

cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId

Module: CIENA-CES-BENCHMARK-MIB

OID (symbolic): CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId

OID (numeric): 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: ID of the EMIX sequence that was used for running the test which produced these results. When 0, frame size indicates the size of the test frame associated with these results.

What is cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId?

This identifies which EMIX frame-size-mix profile a frame-loss result row was measured against, meaningful only when the companion FrameSize field reads 0, in which case FrameSize alone identifies the single fixed size instead. An admin uses this to confirm whether a reported loss percentage reflects performance under realistic blended traffic rather than one artificial frame size, since a device can pass every individual fixed-size test yet still lose frames under a mixed real-world profile. For example, unexpected loss showing up only when cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId = 2 (and not on any fixed frame size) would suggest the device struggles specifically with size-varying traffic, perhaps due to buffer fragmentation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.8
snmpwalk -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.39.1.1.16.1.8.1
snmpget -v2c -c public <target> CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-BENCHMARK-MIB::cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceId OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.39cienaCesBenchmarkMIBCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1cienaCesBenchmarkMIBObjectsCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1cienaCesBenchmarkModuleCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16cienaCesBenchmarkGenTestSessionFramelossResultsTableCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16.1cienaCesBenchmarkGenTestSessionFramelossResultsEntryCIENA-CES-BENCHMARK-MIB
1.3.6.1.4.1.1271.2.1.39.1.1.16.1.8cienaCesBenchmarkGenTestSessionFramelossResultsEmixSequenceIdCIENA-CES-BENCHMARK-MIB