CHIPCOM-MIB :: ol51nnMTPPLPortBuddySlot

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCHIPCOM-MIBol51nnMTPPLPortBuddySlot

ol51nnMTPPLPortBuddySlot

Module: CHIPCOM-MIB

OID (symbolic): CHIPCOM-MIB::ol51nnMTPPLPortBuddySlot

OID (numeric): 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values.

The buddy is automatically set to be redundant to this port.

If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.

What is ol51nnMTPPLPortBuddySlot?

Configures the slot number of the paired (buddy) port used for port redundancy or remote diagnostics, which must be set along with the buddy port to a valid value to enable redundancy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4
snmpwalk -v2c -c public <target> CHIPCOM-MIB::ol51nnMTPPLPortBuddySlot

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4.1
snmpget -v2c -c public <target> CHIPCOM-MIB::ol51nnMTPPLPortBuddySlot.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4.1 i <value>

Start monitoring Chipcom (3Com) Ethernet/Token Ring switching hub or LAN concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CHIPCOM-MIB::ol51nnMTPPLPortBuddySlot OID value, configure state conditions and alerts, and monitor any Chipcom (3Com) Ethernet/Token Ring switching hub or LAN concentrator (legacy) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.49chipcomCHIPAGENT-MIB
1.3.6.1.4.1.49.2chipmib02CHIPAGENT-MIB
1.3.6.1.4.1.49.2.3chipProductsCHIPAGENT-MIB
1.3.6.1.4.1.49.2.3.1onlineCHIPAGENT-MIB
1.3.6.1.4.1.49.2.3.1.4olModulesCHIPAGENT-MIB
1.3.6.1.4.1.49.2.3.1.4.4olSpecModsCHIPAGENT-MIB
1.3.6.1.4.1.49.2.3.1.4.4.18ol51nnMTPPLCHIPAGENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.49.2.3.1.4.4.18.2ol51nnMTPPLPortTableCHIPCOM-MIB
1.3.6.1.4.1.49.2.3.1.4.4.18.2.1ol51nnMTPPLPortEntryCHIPCOM-MIB
1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4ol51nnMTPPLPortBuddySlotCHIPCOM-MIB