CADANT-HW-MEAS-MIB :: cadantUFIDMeasSIDMicroreflections

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCADANT-HW-MEAS-MIBcadantUFIDMeasSIDMicroreflections

cadantUFIDMeasSIDMicroreflections

Module: CADANT-HW-MEAS-MIB

OID (symbolic): CADANT-HW-MEAS-MIB::cadantUFIDMeasSIDMicroreflections

OID (numeric): 1.3.6.1.4.1.4998.1.1.10.2.6.1.25

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: refer to docsIfCmtsCmStatusMicroreflections

What is cadantUFIDMeasSIDMicroreflections?

Reports the level of upstream microreflections measured for this flow's SID, equivalent to docsIfCmtsCmStatusMicroreflections. Microreflections are signal echoes caused by impedance mismatches in the coaxial plant and can degrade upstream data quality.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.10.2.6.1.25
snmpwalk -v2c -c public <target> CADANT-HW-MEAS-MIB::cadantUFIDMeasSIDMicroreflections

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.10.2.6.1.25.1
snmpget -v2c -c public <target> CADANT-HW-MEAS-MIB::cadantUFIDMeasSIDMicroreflections.1

Start monitoring ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-HW-MEAS-MIB::cadantUFIDMeasSIDMicroreflections OID value, configure state conditions and alerts, and monitor any ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.10cadEquipmentCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.10.2cadHardwareMeasMibCADANT-HW-MEAS-MIB
1.3.6.1.4.1.4998.1.1.10.2.6cadantUFIDMeasTableCADANT-HW-MEAS-MIB
1.3.6.1.4.1.4998.1.1.10.2.6.1cadantUFIDMeasEntryCADANT-HW-MEAS-MIB
1.3.6.1.4.1.4998.1.1.10.2.6.1.25cadantUFIDMeasSIDMicroreflectionsCADANT-HW-MEAS-MIB