cadIfUpChannelSlotSize

Module: CADANT-CMTS-UPCHANNEL-MIB

OID (symbolic): CADANT-CMTS-UPCHANNEL-MIB::cadIfUpChannelSlotSize

OID (numeric): 1.3.6.1.4.1.4998.1.1.15.3.2.1.8

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The number of 6.25 microsecond ticks in each upstream mini- slot. Returns zero if the value is undefined or unknown. See the associated conformance object for write conditions and limitations.

What is cadIfUpChannelSlotSize?

Sets the size of each upstream mini-slot expressed as a count of 6.25-microsecond ticks, which determines the basic unit of upstream bandwidth allocation. A value of zero means the slot size is not yet defined or is unknown.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.15.3.2.1.8
snmpwalk -v2c -c public <target> CADANT-CMTS-UPCHANNEL-MIB::cadIfUpChannelSlotSize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.15.3.2.1.8.1
snmpget -v2c -c public <target> CADANT-CMTS-UPCHANNEL-MIB::cadIfUpChannelSlotSize.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4998.1.1.15.3.2.1.8.1 i <value>

Start monitoring ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CADANT-CMTS-UPCHANNEL-MIB::cadIfUpChannelSlotSize OID value, configure state conditions and alerts, and monitor any ARRIS/Cadant C4/E6000 CMTS (cable modem termination system) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.15cadSpectrumCADANT-PRODUCTS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4998.1.1.15.3cadUpchannelMibCADANT-CMTS-UPCHANNEL-MIB
1.3.6.1.4.1.4998.1.1.15.3.2cadIfUpstreamChannelTableCADANT-CMTS-UPCHANNEL-MIB
1.3.6.1.4.1.4998.1.1.15.3.2.1cadIfUpstreamChannelEntryCADANT-CMTS-UPCHANNEL-MIB
1.3.6.1.4.1.4998.1.1.15.3.2.1.8cadIfUpChannelSlotSizeCADANT-CMTS-UPCHANNEL-MIB