CADANT-CMTS-PACKETCABLE-MIB :: cadPCMaxOverloadCalls

MIB Reference — IPNetwork Monitor

All MIBsCADANT-CMTS-PACKETCABLE-MIBcadPCMaxOverloadCalls

cadPCMaxOverloadCalls

Module: CADANT-CMTS-PACKETCABLE-MIB

OID (symbolic): CADANT-CMTS-PACKETCABLE-MIB::cadPCMaxOverloadCalls

OID (numeric): 1.3.6.1.4.1.4998.1.1.115.1.1.14

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description:

the max number of connections we will allow per 10 second interval when the system cpu is in a normal condition, i.e. no overload.

What is cadPCMaxOverloadCalls?

Sets the maximum total number of PacketCable call connections (across all call types) the CMTS will accept per 10-second interval when the CPU is in a normal, non-overloaded state. This provides a global admission-control ceiling during healthy operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.115.1.1.14
snmpwalk -v2c -c public <target> CADANT-CMTS-PACKETCABLE-MIB::cadPCMaxOverloadCalls

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4998.1.1.115.1.1.14.1
snmpget -v2c -c public <target> CADANT-CMTS-PACKETCABLE-MIB::cadPCMaxOverloadCalls.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4998.1.1.115.1.1.14.1 i <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.4998cadantCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1cadObjectsCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1cadCableCADANT-PRODUCTS-MIB
1.3.6.1.4.1.4998.1.1.115cadPCMIBCADANT-CMTS-PACKETCABLE-MIB
1.3.6.1.4.1.4998.1.1.115.1cadPCMibObjectsCADANT-CMTS-PACKETCABLE-MIB
1.3.6.1.4.1.4998.1.1.115.1.1cadPCMibBaseCADANT-CMTS-PACKETCABLE-MIB
1.3.6.1.4.1.4998.1.1.115.1.1.14cadPCMaxOverloadCallsCADANT-CMTS-PACKETCABLE-MIB