Baytech-MIB-401-4

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsBaytech-MIB-401-4

Category: Vendor: Baytech

Description: Manages Baytech remote power management unit model 401 series, providing outlet control and power consumption monitoring.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is Baytech-MIB-401-4?

The Baytech-MIB-401-4 module is a vendor-specific MIB from Baytech, a remote power distribution unit (PDU) manufacturer, covering its 401-series intelligent power controllers used to remotely switch and monitor AC outlets in data center racks. It exposes device identity information (firmware revision, serial number, unit name/description) alongside network management configuration such as BOOTP/DHCP, SSH/Telnet access, activity timeout, direct-connect mode, and SNMP read-only/read-write community strings. For monitoring purposes it is used to confirm hardware/software identity and status - firmware version and serial number - and to verify which management protocols and access controls are enabled, important for both operational and security auditing. The visible objects do not show per-outlet power-consumption metering directly, though the wider Baytech MIB family typically extends this with outlet control and load-current tables. It has no notable external MIB dependency beyond Baytech's own private enterprise tree, and is typically deployed in data center and telecom equipment racks where a Baytech PDU remotely controls power to attached servers/network gear. Engineers can download the Baytech-MIB-401-4 file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in Baytech-MIB-401-4. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Baytech remote power distribution unit (PDU)
  • 401-series power controller

Monitoring Examples

An administrator polling sBTAIdentFirmwareRev and sBTAIdentSerialNumber can confirm exactly which firmware build and hardware unit is deployed at a given rack location, useful when auditing for a known firmware vulnerability. Checking sBTANetworkConfigSSHEnable, sBTANetworkConfigTelnetEnable, and sBTANetworkConfigSNMPReadWriteCommunity reveals whether insecure management protocols or default community strings are still active, an important security posture check. sBTANetworkConfigActivityTimeout shows the configured session idle timeout, and sBTAIdentUnitName lets NMS tools display a human-readable label for the PDU in alert dashboards.

What Can Be Monitored

  • firmware revision
  • serial number
  • unit name
  • SSH/Telnet access enablement
  • SNMP community strings
  • session activity timeout
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Gauge
IpAddress
TimeTicks
enterprises

From RFC1213-MIB

DisplayString
OIDs

RFC description

Baytech MIB for the Baytech 401/4 remote power distribution unit (PDU), providing monitoring of outlet states, power consumption, and power cycling capabilities for data center equipment.

Start monitoring Baytech 401-series power controller/PDU (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download Baytech-MIB-401-4