All MIBs › BTI-7000-MIB
Organization: BTI Systems Inc.
Last Updated: 2012-10-09
Category: Optical and WDM, Vendor: BTI Systems
Description: Manages BTI Systems BTI-7000 series optical transport network equipment configuration and alarms.
4,153 OIDs total — showing 3,011-4,153 (page 2 of 2)
« Prev Page 2 of 2
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| FIX briHistPMOPRAvgValue | 1.3.6.1.4.1.18070.2.2.1.6.39.1.29 | FixedX10 | read-only | The average optical power received on the input of the transceiver. |
| DAT briHistPMOPRAvgTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.39.1.30 | DateAndTime | read-only | The date and time stamp of the average optical power received value. |
| PMV briHistPMOPRAvgValidity | 1.3.6.1.4.1.18070.2.2.1.6.39.1.31 | PMValidity | read-only | Indicates the validity of the provided average optical power received value. |
| INI briHistPMOPRAvgInitialize | 1.3.6.1.4.1.18070.2.2.1.6.39.1.32 | InitializeCmd | read-write | Used to initialize the value of the briHistPMOPRAvgValue object to 0. |
| FIX briHistPMOPTMinValue | 1.3.6.1.4.1.18070.2.2.1.6.39.1.33 | FixedX10 | read-only | The minimum optical power transmitted at the output of the transceiver. |
| DAT briHistPMOPTMinTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.39.1.34 | DateAndTime | read-only | The date and time stamp of the minimum optical power transmitted value. |
| PMV briHistPMOPTMinValidity | 1.3.6.1.4.1.18070.2.2.1.6.39.1.35 | PMValidity | read-only | Indicates the validity of the provided minimum optical power transmitted value. |
| INI briHistPMOPTMinInitialize | 1.3.6.1.4.1.18070.2.2.1.6.39.1.36 | InitializeCmd | read-write | Used to initialize the value of the briHistPMOPTMinValue object to 0. |
| FIX briHistPMOPTMaxValue | 1.3.6.1.4.1.18070.2.2.1.6.39.1.37 | FixedX10 | read-only | The maximum optical power transmitted at the output of the transceiver. |
| DAT briHistPMOPTMaxTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.39.1.38 | DateAndTime | read-only | The date and time stamp of the maximum optical power transmitted value. |
| PMV briHistPMOPTMaxValidity | 1.3.6.1.4.1.18070.2.2.1.6.39.1.39 | PMValidity | read-only | Indicates the validity of the provided maximum optical power transmitted value. |
| INI briHistPMOPTMaxInitialize | 1.3.6.1.4.1.18070.2.2.1.6.39.1.40 | InitializeCmd | read-write | Used to initialize the value of the briHistPMOPTMaxValue object to 0. |
| FIX briHistPMOPTAvgValue | 1.3.6.1.4.1.18070.2.2.1.6.39.1.41 | FixedX10 | read-only | The average optical power transmitted at the output of the transceiver. |
| DAT briHistPMOPTAvgTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.39.1.42 | DateAndTime | read-only | The date and time stamp of the average optical power transmitted value. |
| PMV briHistPMOPTAvgValidity | 1.3.6.1.4.1.18070.2.2.1.6.39.1.43 | PMValidity | read-only | Indicates the validity of the provided average optical power transmitted value. |
| INI briHistPMOPTAvgInitialize | 1.3.6.1.4.1.18070.2.2.1.6.39.1.44 | InitializeCmd | read-write | Used to initialize the value of the briHistPMOPTAvgValue object to 0. |
| cpCrntPMTable | 1.3.6.1.4.1.18070.2.2.1.6.49 | not-accessible | A table of current performance monitoring statistics collected for the circuit packs on the NE. | |
| cpCrntPMEntry | 1.3.6.1.4.1.18070.2.2.1.6.49.1 | not-accessible | The row entry object of the equipment current performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a current measurement interval for a given circuit pack. | |
| CPT cpCrntPMCpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.6.49.1.1 | CpType | not-accessible | The type of the circuit pack targeted for PM retrieval. |
| INT cpCrntPMShelfIdx | 1.3.6.1.4.1.18070.2.2.1.6.49.1.2 | INTEGER | not-accessible | The number of the shelf on which the circuit pack targeted for PMs is provisioned. |
| INT cpCrntPMSlotIdx | 1.3.6.1.4.1.18070.2.2.1.6.49.1.3 | INTEGER | not-accessible | The number of the slot within which the circuit pack targeted for PMs is provisioned. |
| NUM cpCrntPMIntervalTypeIdx | 1.3.6.1.4.1.18070.2.2.1.6.49.1.4 | PMIntervalType | not-accessible | The type of PM bin according to interval length. |
| INT cpCrntPMTempValue | 1.3.6.1.4.1.18070.2.2.1.6.49.1.5 | INTEGER | read-only | The circuit pack temperature. |
| DAT cpCrntPMTempTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.49.1.6 | DateAndTime | read-only | The date and time stamp of the temperature value. |
| PMV cpCrntPMTempValidity | 1.3.6.1.4.1.18070.2.2.1.6.49.1.7 | PMValidity | read-only | Indicates the validity of the provided temperature value. |
| cpHistPMTable | 1.3.6.1.4.1.18070.2.2.1.6.50 | not-accessible | A table of historical performance monitoring statistics collected for the circuit packs on the NE. | |
| cpHistPMEntry | 1.3.6.1.4.1.18070.2.2.1.6.50.1 | not-accessible | The row entry object of the circuit pack historical performance monitoring table. Each row of this table contains a full set of PM statistics and related data for a historical measurement interval for a given circuit pack. | |
| CPT cpHistPMCpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.6.50.1.1 | CpType | not-accessible | The type of the circuit pack targeted for PM retrieval. |
| INT cpHistPMShelfIdx | 1.3.6.1.4.1.18070.2.2.1.6.50.1.2 | INTEGER | not-accessible | The number of the shelf on which the circuit pack targeted for PMs is provisioned. |
| INT cpHistPMSlotIdx | 1.3.6.1.4.1.18070.2.2.1.6.50.1.3 | INTEGER | not-accessible | The number of the slot within which the circuit pack targeted for PMs is provisioned. |
| NUM cpHistPMIntervalTypeIdx | 1.3.6.1.4.1.18070.2.2.1.6.50.1.4 | PMIntervalType | not-accessible | The type of PM bin according to interval length. |
| INT cpHistPMIntervalIdx | 1.3.6.1.4.1.18070.2.2.1.6.50.1.5 | INTEGER | not-accessible | The specific PM bin number. The range is 1..96 for 15-minute bins, and for 1-day historical bins, the value is 1. |
| INT cpHistPMTempValue | 1.3.6.1.4.1.18070.2.2.1.6.50.1.6 | INTEGER | read-only | The circuit pack temperature. |
| DAT cpHistPMTempTimeStamp | 1.3.6.1.4.1.18070.2.2.1.6.50.1.7 | DateAndTime | read-only | The date and time stamp of the temperature value. |
| PMV cpHistPMTempValidity | 1.3.6.1.4.1.18070.2.2.1.6.50.1.8 | PMValidity | read-only | Indicates the validity of the provided temperature value. |
| conditions | 1.3.6.1.4.1.18070.2.2.1.7 | |||
| notifObjects | 1.3.6.1.4.1.18070.2.2.1.7.1 | |||
| DAT condDateAndTime | 1.3.6.1.4.1.18070.2.2.1.7.1.1 | DateAndTime | accessible-for-notify | This object is used in Trap messages to indicate the date and time at which the condition or alarm reported in the Trap message occurred. |
| CON condReportType | 1.3.6.1.4.1.18070.2.2.1.7.1.2 | CondReportType | accessible-for-notify | Indicates if this is a condition (non-alarmed) or an alarm. This object is used solely for reporting the condition report type in Trap messages. |
| CON condSeverity | 1.3.6.1.4.1.18070.2.2.1.7.1.3 | CondSeverity | accessible-for-notify | Indicates the severity of the condition or alarm. This object is used solely for reporting the condition severity in Trap messages. |
| CON condServiceAffecting | 1.3.6.1.4.1.18070.2.2.1.7.1.4 | CondServiceAffecting | accessible-for-notify | Indicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected. This object is used solely for reporting whether or not a condition is service affecting in Trap messages. |
| STR condDescription | 1.3.6.1.4.1.18070.2.2.1.7.1.5 | DisplayString | accessible-for-notify | A textual decription of the condition or alarm. This object is used solely for reporting the condition description in Trap messages. |
| NOT condObjectType | 1.3.6.1.4.1.18070.2.2.1.7.1.6 | NotifObjectType | accessible-for-notify | Identifies the type of managed object against which the condition or alarm is raised. |
| NOT condCodeType | 1.3.6.1.4.1.18070.2.2.1.7.1.7 | NotifCodeType | accessible-for-notify | This object value uniquely identifies the type of condition or alarm that is raised. |
| actCondTable | 1.3.6.1.4.1.18070.2.2.1.7.2 | not-accessible | This table lists all active conditions and alarms raised on the system. | |
| actCondEntry | 1.3.6.1.4.1.18070.2.2.1.7.2.1 | not-accessible | Contains identifying and descriptive attributes for a single active condition or alarm raised on the network element. | |
| OID actCondNotifIdx | 1.3.6.1.4.1.18070.2.2.1.7.2.1.1 | OBJECT IDENTIFIER | not-accessible | Identifies the type of condition or alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm. |
| OID actCondTableEntryIdx | 1.3.6.1.4.1.18070.2.2.1.7.2.1.2 | OBJECT IDENTIFIER | not-accessible | Identifies the type of resource that is alarmed by pointing to the corresponding table entry object. |
| STR actCondInstanceIdx | 1.3.6.1.4.1.18070.2.2.1.7.2.1.3 | DisplayString | not-accessible | Identifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actCondTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string. |
| CON actCondReportType | 1.3.6.1.4.1.18070.2.2.1.7.2.1.4 | CondReportType | read-only | Indicates if the table entry is a condition (non-alarmed) or an alarm. |
| DAT actCondDateAndTime | 1.3.6.1.4.1.18070.2.2.1.7.2.1.5 | DateAndTime | read-only | The date and time that the condition or alarm reported in the trap message was raised. |
| CON actCondSeverity | 1.3.6.1.4.1.18070.2.2.1.7.2.1.6 | CondSeverity | read-only | Indicates how severe the condition or alarm is. |
| CON actCondServiceAffecting | 1.3.6.1.4.1.18070.2.2.1.7.2.1.7 | CondServiceAffecting | read-only | Indicates if the presence of this active condition or alarm impacts the ability of the equipment to provide service as expected. |
| STR actCondDescription | 1.3.6.1.4.1.18070.2.2.1.7.2.1.8 | DisplayString | read-only | A textual decription of the condition or alarm. |
| NOT actCondObjectType | 1.3.6.1.4.1.18070.2.2.1.7.2.1.9 | NotifObjectType | read-only | Identifies the type of managed object against which the condition or alarm is raised. |
| NOT actCondCodeType | 1.3.6.1.4.1.18070.2.2.1.7.2.1.10 | NotifCodeType | read-only | This object value uniquely identifies the type of condition or alarm that is raised. |
| INT actCondSummary | 1.3.6.1.4.1.18070.2.2.1.7.3 | INTEGER | read-only | This object summarizes the active alarm/condition status of the network element. The value of the object returned indicates the following status data: - noActiveConditions: there are no active alarms or conditions on the network element - nonAlarmedConditionsActive: there is one or more active conditions on the network element, but none are of alarmable severity - minorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is minor - majorAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is major - criticalAlarmsActive: there is one or more active conditions and/or alarms on the network element, and the highest severity level alarm is critical |
| actAlarmTable | 1.3.6.1.4.1.18070.2.2.1.7.4 | not-accessible | This table lists all active alarms raised on the system. | |
| actAlarmEntry | 1.3.6.1.4.1.18070.2.2.1.7.4.1 | not-accessible | Contains identifying and descriptive attributes for a single active alarm raised on the system. | |
| OID actAlarmNotifIdx | 1.3.6.1.4.1.18070.2.2.1.7.4.1.1 | OBJECT IDENTIFIER | not-accessible | Identifies the type of alarm that is active by pointing to the NOTIFICATION-TYPE object that corresponds to the raising event of the condition or alarm. |
| OID actAlarmTableEntryIdx | 1.3.6.1.4.1.18070.2.2.1.7.4.1.2 | OBJECT IDENTIFIER | not-accessible | Identifies the type of resource that is alarmed by pointing to the corresponding table entry object. |
| STR actAlarmInstanceIdx | 1.3.6.1.4.1.18070.2.2.1.7.4.1.3 | DisplayString | not-accessible | Identifies the specific instance of the idenitifed resource type that is alarmed by providing instance data that applies to an instance of the table entry object type identified by actAlarmTableEntryIdx. The instance data portion of the OID is mapped to an OCTET string. |
| CON actAlarmReportType | 1.3.6.1.4.1.18070.2.2.1.7.4.1.4 | CondReportType | read-only | Indicates if the table entry is an alarm. |
| DAT actAlarmDateAndTime | 1.3.6.1.4.1.18070.2.2.1.7.4.1.5 | DateAndTime | read-only | The date and time that the alarm reported in the trap message was raised. |
| CON actAlarmSeverity | 1.3.6.1.4.1.18070.2.2.1.7.4.1.6 | CondSeverity | read-only | Indicates how severe the alarm is. |
| CON actAlarmServiceAffecting | 1.3.6.1.4.1.18070.2.2.1.7.4.1.7 | CondServiceAffecting | read-only | Indicates if the presence of this active alarm impacts the ability of the equipment to provide service as expected. |
| STR actAlarmDescription | 1.3.6.1.4.1.18070.2.2.1.7.4.1.8 | DisplayString | read-only | A textual decription of the alarm. |
| NOT actAlarmObjectType | 1.3.6.1.4.1.18070.2.2.1.7.4.1.9 | NotifObjectType | read-only | Identifies the type of managed object against which the alarm is raised. |
| NOT actAlarmCodeType | 1.3.6.1.4.1.18070.2.2.1.7.4.1.10 | NotifCodeType | read-only | This object value uniquely identifies the type of alarm that is raised. |
| administration | 1.3.6.1.4.1.18070.2.2.1.8 | |||
| tl1UserTable | 1.3.6.1.4.1.18070.2.2.1.8.1 | not-accessible | This table contains one row for every provisioned user that can operate the TL1 management interface on the NE. Each row contains a list of attributes that pertain to a provisioned TL1 user. | |
| tl1UserEntry | 1.3.6.1.4.1.18070.2.2.1.8.1.1 | not-accessible | The conceptual row object of the TL1 user table. | |
| STR tl1UserIdx | 1.3.6.1.4.1.18070.2.2.1.8.1.1.1 | DisplayString | accessible-for-notify | This is the unique user identifier, or UID, that is used for TL1 access. |
| STR tl1IpLockoutAddr | 1.3.6.1.4.1.18070.2.2.1.8.2 | DisplayString | accessible-for-notify | This is an IP address from which TL1 user login attempts have been temporarily disabled due to an excessive number of failed user login attempts. |
| tl1LogTable | 1.3.6.1.4.1.18070.2.2.1.8.3 | not-accessible | This table lists all the log entries generated by the TL1 interface on the BTI 7000 system. | |
| tl1LogEntry | 1.3.6.1.4.1.18070.2.2.1.8.3.1 | not-accessible | The conceptual row object of the TL1 log table. | |
| U32 tl1LogIdx | 1.3.6.1.4.1.18070.2.2.1.8.3.1.1 | Unsigned32 | not-accessible | The unique identifier for this log entry. It is the global Log Id of the entry when viewed through the TL1 interface. |
| STR tl1LogSysName | 1.3.6.1.4.1.18070.2.2.1.8.3.1.2 | DisplayString | read-only | The name of the BTI 7000 system at the time that the log was recorded. |
| INT tl1LogType | 1.3.6.1.4.1.18070.2.2.1.8.3.1.3 | INTEGER | read-only | The type of log entry. |
| U32 tl1LogTypeSpecificLogNum | 1.3.6.1.4.1.18070.2.2.1.8.3.1.4 | Unsigned32 | read-only | The type-specific number for this log. |
| STR tl1LogMsgCode | 1.3.6.1.4.1.18070.2.2.1.8.3.1.5 | DisplayString | read-only | The message code that was issued for this log entry. This field is relevant to log entries for TL1 autonomous notifications. For example, the message code may be 'REPT ALM OC48'. A message code is reported for all log entries of type alarm, event and dbChange. For logs of type security or command, the message code is an empty string. |
| DAT tl1LogDateAndTime | 1.3.6.1.4.1.18070.2.2.1.8.3.1.6 | DateAndTime | read-only | The timestamp of the log entry. |
| STR tl1LogMessage | 1.3.6.1.4.1.18070.2.2.1.8.3.1.7 | DisplayString | read-only | This is the main log entry contents. The log entry is enclosed in double quotations. |
| U32 latestTl1LogNum | 1.3.6.1.4.1.18070.2.2.1.8.4 | Unsigned32 | read-only | Identifies the value of the tl1LogIdx object for the most recently added entry in the tl1LogTable. |
| snmpTrapRcvTable | 1.3.6.1.4.1.18070.2.2.1.8.5 | not-accessible | This table contains one row for every configured SNMP trap receiver. Each row contains a list of attributes that pertain to a provisioned trap receiver. All access to this table, whether for read, write, or create requests are restricted to SNMP requests issued with a valid community string configured with read-write access. | |
| snmpTrapRcvEntry | 1.3.6.1.4.1.18070.2.2.1.8.5.1 | not-accessible | The conceptual row object of the SNMP trap receiver table. | |
| STR snmpTrapRcvIdx | 1.3.6.1.4.1.18070.2.2.1.8.5.1.1 | DisplayString | read-create | This string serves as a unique trap receiver Id and is used to index the table. |
| IP snmpTrapRcvIPAddr | 1.3.6.1.4.1.18070.2.2.1.8.5.1.2 | IpAddress | read-create | The IP address of the trap receiver. The setting of this object is mandatory when creating a new row. |
| INT snmpTrapRcvPort | 1.3.6.1.4.1.18070.2.2.1.8.5.1.3 | INTEGER | read-create | The port on the specified IP address of the trap receiver. |
| INT snmpTrapRcvNotifType | 1.3.6.1.4.1.18070.2.2.1.8.5.1.4 | INTEGER | read-create | The type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c. |
| INT snmpTrapRcvVersion | 1.3.6.1.4.1.18070.2.2.1.8.5.1.5 | INTEGER | read-create | The type of notification service to be provided to the trap receiver. The notification type can be configured as inform only if the message version specified for the snmpTrapRcvVersion object is snmpv2c. The setting of this object is mandatory when creating a new row. |
| STR snmpTrapRcvCommunity | 1.3.6.1.4.1.18070.2.2.1.8.5.1.6 | DisplayString | read-create | The community string inserted into the trap messages generated for this trap receiver. The setting of this object is mandatory when creating a new row. |
| HOU snmpTrapRcvTTL | 1.3.6.1.4.1.18070.2.2.1.8.5.1.7 | HoursAndMinutes | read-create | The time-to-live for the trap receiver. When the trap receiver is created or this object is set, this object specifies how long the trap receiver is to be configured. When read, the value returned is the length of time remaining before the trap receiver is automatically deleted. The valid range for this object is 000-00 to 099-99. If this object is set to a value of 000-00, the trap receiver will never auto-delete. |
| ROW snmpTrapRcvRowStatus | 1.3.6.1.4.1.18070.2.2.1.8.5.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the SNMP trap receiver table. |
| connections | 1.3.6.1.4.1.18070.2.2.1.9 | |||
| xcvrXCTable | 1.3.6.1.4.1.18070.2.2.1.9.1 | not-accessible | This table contains one row for every provisioned cross connection between optical transceiver facilities on wavelength translator, regenerator and manager circuit packs. | |
| xcvrXCEntry | 1.3.6.1.4.1.18070.2.2.1.9.1.1 | not-accessible | The conceptual row object of the optical transceiver cross connection table. | |
| XCV xcvrXCSrcTypeIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.1 | XcvrType | not-accessible | The specific type of wavelength conversion function of the transceiver port that serves as the source port for the cross connection. |
| INT xcvrXCSrcShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.2 | INTEGER | not-accessible | The number of the shelf of the transceiver port that serves as the source port for the cross connection. |
| INT xcvrXCSrcSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.3 | INTEGER | not-accessible | The number of the slot of the transceiver port that serves as the source port for the cross connection. |
| INT xcvrXCSrcIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.4 | INTEGER | not-accessible | The number of the port of the transceiver port that serves as the source port for the cross connection. |
| XCV xcvrXCDestTypeIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.5 | XcvrType | not-accessible | The specific type of wavelength conversion function of the transceiver port that serves as the destination port for the cross connection. |
| INT xcvrXCDestShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.6 | INTEGER | not-accessible | The number of the shelf of the transceiver port that serves as the destination port for the cross connection. |
| INT xcvrXCDestSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.7 | INTEGER | not-accessible | The number of the slot of the transceiver port that serves as the destination port for the cross connection. |
| INT xcvrXCDestIdx | 1.3.6.1.4.1.18070.2.2.1.9.1.1.8 | INTEGER | not-accessible | The number of the port of the transceiver port that serves as the destination port for the cross connection. |
| XCT xcvrXCType | 1.3.6.1.4.1.18070.2.2.1.9.1.1.9 | XCType | read-create | The type of cross connection between the identified source and destination transceiver ports. This is a mandatory object when a row of the transceiver cross connect table is created. Only 1-way and 2-way cross-connections are supported on optical transceiver ports |
| ROW xcvrXCRowStatus | 1.3.6.1.4.1.18070.2.2.1.9.1.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the transceiver cross connection table, which in turn controls the provisioning and de-provisioning of transceiver cross connections. |
| vcgXCTable | 1.3.6.1.4.1.18070.2.2.1.9.2 | not-accessible | This table contains one row for every provisioned cross connection between VCGs on Muxponder circuit packs. | |
| vcgXCEntry | 1.3.6.1.4.1.18070.2.2.1.9.2.1 | not-accessible | The conceptual row object of the VCG cross connection table. | |
| INT vcgXCSrcShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.1 | INTEGER | not-accessible | The number of the shelf of the VCG entity that serves as the source port for the cross connection. |
| INT vcgXCSrcSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.2 | INTEGER | not-accessible | The number of the slot of the VCG entity that serves as the source port for the cross connection. |
| INT vcgXCSrcPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.3 | INTEGER | not-accessible | The number of the port of the VCG entity that serves as the source port for the cross connection. |
| INT vcgXCSrcIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.4 | INTEGER | not-accessible | The number of the VCG within the identified port that serves as the source port for the cross connection. |
| INT vcgXCDestShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.5 | INTEGER | not-accessible | The number of the shelf of the VCG entity that serves as the destination port for the cross connection. |
| INT vcgXCDestSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.6 | INTEGER | not-accessible | The number of the slot of the VCG entity that serves as the destination port for the cross connection. |
| INT vcgXCDestPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.7 | INTEGER | not-accessible | The number of the port of the VCG entity that serves as the destination port for the cross connection. |
| INT vcgXCDestIdx | 1.3.6.1.4.1.18070.2.2.1.9.2.1.8 | INTEGER | not-accessible | The number of the VCG within the identified port that serves as the destination port for the cross connection. |
| XCT vcgXCType | 1.3.6.1.4.1.18070.2.2.1.9.2.1.9 | XCType | read-create | The type of cross connection between the identified source and destination VCG entities. This is a mandatory object when a row of the VCG cross connect table is created. Only 2-way and 2-way protected cross-connections are supported between VCGs. |
| INT vcgXCProtShelfNum | 1.3.6.1.4.1.18070.2.2.1.9.2.1.10 | INTEGER | read-create | The number of the shelf of the VCG entity that serves as the protection port for the cross connection. |
| INT vcgXCProtSlotNum | 1.3.6.1.4.1.18070.2.2.1.9.2.1.11 | INTEGER | read-create | The number of the slot of the VCG entity that serves as the protection port for the cross connection. |
| INT vcgXCProtPortNum | 1.3.6.1.4.1.18070.2.2.1.9.2.1.12 | INTEGER | read-create | The number of the port of the VCG entity that serves as the protection port for the cross connection. |
| INT vcgXCProtNum | 1.3.6.1.4.1.18070.2.2.1.9.2.1.13 | INTEGER | read-create | The number of the VCG within the identified port that serves as the protection port for the cross connection. |
| ROW vcgXCRowStatus | 1.3.6.1.4.1.18070.2.2.1.9.2.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the VCG cross connection table, which in turn controls the provisioning and de-provisioning of VCG cross connections. |
| stsnXCTable | 1.3.6.1.4.1.18070.2.2.1.9.3 | not-accessible | This table contains one row for every provisioned cross connection between SONET STS-N facilities on Muxponder circuit packs. | |
| stsnXCEntry | 1.3.6.1.4.1.18070.2.2.1.9.3.1 | not-accessible | The conceptual row object of the STS-N cross connection table. | |
| STS stsnXCStsnTypeIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.1 | StsnType | not-accessible | The specific STS-N rate of the cross-connection. |
| INT stsnXCSrcShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.2 | INTEGER | not-accessible | The number of the shelf of the STS-N facility that serves as the source end-point for the cross connection. |
| INT stsnXCSrcSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.3 | INTEGER | not-accessible | The number of the slot of the STS-N facility that serves as the source end-point for the cross connection. |
| INT stsnXCSrcPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.4 | INTEGER | not-accessible | The number of the port of the STS-N facility that serves as the source end-point for the cross connection. |
| INT stsnXCSrcIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.5 | INTEGER | not-accessible | The number of the STS-N within the identified port that serves as the source end-point for the cross connection. |
| INT stsnXCDestShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.6 | INTEGER | not-accessible | The number of the shelf of the STS-N facility that serves as the destination end-point for the cross connection. |
| INT stsnXCDestSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.7 | INTEGER | not-accessible | The number of the slot of the STS-N entity that serves as the destination end-point for the cross connection. |
| INT stsnXCDestPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.8 | INTEGER | not-accessible | The number of the port of the STS-N entity that serves as the destination end-point for the cross connection. |
| INT stsnXCDestIdx | 1.3.6.1.4.1.18070.2.2.1.9.3.1.9 | INTEGER | not-accessible | The number of the STS-N within the identified port that serves as the destination end-point for the cross connection. |
| XCT stsnXCType | 1.3.6.1.4.1.18070.2.2.1.9.3.1.10 | XCType | read-create | The type of cross connection between the identified source and destination STS-N facilities. This is a mandatory object when a row of the STS-N cross connect table is created. Only 2-way cross-connections are supported between STS-Ns. |
| STS stsnXCProtTypeNum | 1.3.6.1.4.1.18070.2.2.1.9.3.1.11 | StsnType | read-create | The rate of the STS-N facility that serves as the protection end-point for the cross connection. |
| INT stsnXCProtShelfNum | 1.3.6.1.4.1.18070.2.2.1.9.3.1.12 | INTEGER | read-create | The number of the shelf of the STS-N entity that serves as the protection end-point for the cross connection. |
| INT stsnXCProtSlotNum | 1.3.6.1.4.1.18070.2.2.1.9.3.1.13 | INTEGER | read-create | The number of the slot of the STS-N entity that serves as the protection end-point for the cross connection. |
| INT stsnXCProtPortNum | 1.3.6.1.4.1.18070.2.2.1.9.3.1.14 | INTEGER | read-create | The number of the port of the STS-N entity that serves as the protection end-point for the cross connection. |
| INT stsnXCProtNum | 1.3.6.1.4.1.18070.2.2.1.9.3.1.15 | INTEGER | read-create | The number of the STS-N within the identified port that serves as the protection end-point for the cross connection. |
| ROW stsnXCRowStatus | 1.3.6.1.4.1.18070.2.2.1.9.3.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the STS-N cross connection table, which in turn controls the provisioning and de-provisioning of STS-N cross connections. |
| vcnXCTable | 1.3.6.1.4.1.18070.2.2.1.9.4 | not-accessible | This table contains one row for every provisioned cross connection between SDH VC-N facilities on Muxponder circuit packs. | |
| vcnXCEntry | 1.3.6.1.4.1.18070.2.2.1.9.4.1 | not-accessible | The conceptual row object of the VC-N cross connection table. | |
| VCN vcnXCVcnTypeIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.1 | VcnType | not-accessible | The specific rate of the VC-N cross-connection. |
| INT vcnXCSrcShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.2 | INTEGER | not-accessible | The number of the shelf of the VC-N facility that serves as the source end-point for the cross connection. |
| INT vcnXCSrcSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.3 | INTEGER | not-accessible | The number of the slot of the VC-N facility that serves as the source end-point for the cross connection. |
| INT vcnXCSrcPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.4 | INTEGER | not-accessible | The number of the port of the VC-N facility that serves as the source end-point for the cross connection. |
| INT vcnXCSrcIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.5 | INTEGER | not-accessible | The number of the VC-N within the identified port that serves as the source end-point for the cross connection. |
| INT vcnXCDestShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.6 | INTEGER | not-accessible | The number of the shelf of the VC-N facility that serves as the destination end-point for the cross connection. |
| INT vcnXCDestSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.7 | INTEGER | not-accessible | The number of the slot of the VC-N entity that serves as the destination end-point for the cross connection. |
| INT vcnXCDestPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.8 | INTEGER | not-accessible | The number of the port of the VC-N entity that serves as the destination end-point for the cross connection. |
| INT vcnXCDestIdx | 1.3.6.1.4.1.18070.2.2.1.9.4.1.9 | INTEGER | not-accessible | The number of the VC-N within the identified port that serves as the destination end-point for the cross connection. |
| XCT vcnXCType | 1.3.6.1.4.1.18070.2.2.1.9.4.1.10 | XCType | read-create | The type of cross connection between the identified source and destination VC-N facilities. This is a mandatory object when a row of the VC-N cross connect table is created. Only 2-way cross-connections are supported between VC-Ns. |
| VCN vcnXCProtTypeNum | 1.3.6.1.4.1.18070.2.2.1.9.4.1.11 | VcnType | read-create | The rate of the VC-N facility that serves as the protection end-point for the cross connection. |
| INT vcnXCProtShelfNum | 1.3.6.1.4.1.18070.2.2.1.9.4.1.12 | INTEGER | read-create | The number of the shelf of the VC-N entity that serves as the protection end-point for the cross connection. |
| INT vcnXCProtSlotNum | 1.3.6.1.4.1.18070.2.2.1.9.4.1.13 | INTEGER | read-create | The number of the slot of the VC-N entity that serves as the protection end-point for the cross connection. |
| INT vcnXCProtPortNum | 1.3.6.1.4.1.18070.2.2.1.9.4.1.14 | INTEGER | read-create | The number of the port of the VC-N entity that serves as the protection end-point for the cross connection. |
| INT vcnXCProtNum | 1.3.6.1.4.1.18070.2.2.1.9.4.1.15 | INTEGER | read-create | The number of the VC-N within the identified port that serves as the protection end-point for the cross connection. |
| ROW vcnXCRowStatus | 1.3.6.1.4.1.18070.2.2.1.9.4.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the VC-N cross connection table, which in turn controls the provisioning and de-provisioning of VC-N cross connections. |
| odunXCTable | 1.3.6.1.4.1.18070.2.2.1.9.5 | not-accessible | This table contains one row for every provisioned cross connection between OTN ODU-N facilities on Muxponder circuit packs. | |
| odunXCEntry | 1.3.6.1.4.1.18070.2.2.1.9.5.1 | not-accessible | The conceptual row object of the ODU-N cross connection table. | |
| ODU odunXCOdunTypeIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.1 | OdunType | not-accessible | The specific rate of the ODU-N cross-connection. |
| INT odunXCSrcShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.2 | INTEGER | not-accessible | The number of the shelf of the ODU-N facility that serves as the source end-point for the cross connection. |
| INT odunXCSrcSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.3 | INTEGER | not-accessible | The number of the slot of the ODU-N facility that serves as the source end-point for the cross connection. |
| INT odunXCSrcPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.4 | INTEGER | not-accessible | The number of the port of the ODU-N facility that serves as the source end-point for the cross connection. |
| INT odunXCSrcIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.5 | INTEGER | not-accessible | The number of the ODU-N within the identified port that serves as the source end-point for the cross connection. |
| INT odunXCDestShelfIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.6 | INTEGER | not-accessible | The number of the shelf of the ODU-N facility that serves as the destination end-point for the cross connection. |
| INT odunXCDestSlotIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.7 | INTEGER | not-accessible | The number of the slot of the ODU-N entity that serves as the destination end-point for the cross connection. |
| INT odunXCDestPortIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.8 | INTEGER | not-accessible | The number of the port of the ODU-N entity that serves as the destination end-point for the cross connection. |
| INT odunXCDestIdx | 1.3.6.1.4.1.18070.2.2.1.9.5.1.9 | INTEGER | not-accessible | The number of the ODU-N within the identified port that serves as the destination end-point for the cross connection. |
| XCT odunXCType | 1.3.6.1.4.1.18070.2.2.1.9.5.1.10 | XCType | read-create | The type of cross connection between the identified source and destination ODU-N facilities. This is a mandatory object when a row of the ODU-N cross connect table is created. Only 2-way cross-connections are supported between ODU-Ns. |
| ODU odunXCProtTypeNum | 1.3.6.1.4.1.18070.2.2.1.9.5.1.11 | OdunType | read-create | The rate of the ODU-N facility that serves as the protection end-point for the cross connection. |
| INT odunXCProtShelfNum | 1.3.6.1.4.1.18070.2.2.1.9.5.1.12 | INTEGER | read-create | The number of the shelf of the ODU-N entity that serves as the protection end-point for the cross connection. |
| INT odunXCProtSlotNum | 1.3.6.1.4.1.18070.2.2.1.9.5.1.13 | INTEGER | read-create | The number of the slot of the ODU-N entity that serves as the protection end-point for the cross connection. |
| INT odunXCProtPortNum | 1.3.6.1.4.1.18070.2.2.1.9.5.1.14 | INTEGER | read-create | The number of the port of the ODU-N entity that serves as the protection end-point for the cross connection. |
| INT odunXCProtNum | 1.3.6.1.4.1.18070.2.2.1.9.5.1.15 | INTEGER | read-create | The number of the ODU-N within the identified port that serves as the protection end-point for the cross connection. |
| ROW odunXCRowStatus | 1.3.6.1.4.1.18070.2.2.1.9.5.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the ODU-N cross connection table, which in turn controls the provisioning and de-provisioning of ODU-N cross connections. |
| protection | 1.3.6.1.4.1.18070.2.2.1.10 | |||
| xcvrProtGrpTable | 1.3.6.1.4.1.18070.2.2.1.10.1 | not-accessible | This table contains one row for every provisioned protection group pairing between optical transceiver facilities on the wavelength translator, regenerator and manager cards. | |
| xcvrProtGrpEntry | 1.3.6.1.4.1.18070.2.2.1.10.1.1 | not-accessible | The conceptual row object of the optical transceiver protection group table. | |
| XCV xcvrProtGrpWorkTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.1 | XcvrType | not-accessible | The specific type of wavelength conversion function of the transceiver port that serves as the working port for the protection group. |
| INT xcvrProtGrpWorkShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.2 | INTEGER | not-accessible | The number of the shelf of the transceiver port that serves as the working port for the protection group. |
| INT xcvrProtGrpWorkSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.3 | INTEGER | not-accessible | The number of the slot of the transceiver port that serves as the working port for the protection group. |
| INT xcvrProtGrpWorkIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.4 | INTEGER | not-accessible | The number of the port of the transceiver port that serves as the working port for the protection group. |
| XCV xcvrProtGrpProtTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.5 | XcvrType | not-accessible | The specific type of wavelength conversion function of the transceiver port that serves as the protection port for the protection group. |
| INT xcvrProtGrpProtShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.6 | INTEGER | not-accessible | The number of the shelf of the transceiver port that serves as the protection port for the protection group. |
| INT xcvrProtGrpProtSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.7 | INTEGER | not-accessible | The number of the slot of the transceiver port that serves as the protection port for the protection group. |
| INT xcvrProtGrpProtIdx | 1.3.6.1.4.1.18070.2.2.1.10.1.1.8 | INTEGER | not-accessible | The number of the port of the transceiver port that serves as the protection port for the protection group. |
| STR xcvrProtGrpId | 1.3.6.1.4.1.18070.2.2.1.10.1.1.9 | DisplayString | read-create | Textual data recorded by the user to describe the provisioned transceiver protection group in a manner useful to the user. |
| ROW xcvrProtGrpRowStatus | 1.3.6.1.4.1.18070.2.2.1.10.1.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the transceiver protection group table, which in turn controls provisioning and deprovisioning of optical transceiver protection groups. |
| ocnProtGrpTable | 1.3.6.1.4.1.18070.2.2.1.10.2 | not-accessible | This table contains one row for every provisioned protection group pairing between SONET OC-N facilities on Muxponder circuit packs. | |
| ocnProtGrpEntry | 1.3.6.1.4.1.18070.2.2.1.10.2.1 | not-accessible | The conceptual row object of the OC-N facility protection group table. | |
| OCN ocnProtGrpWorkTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.1 | OcnType | not-accessible | The specific rate of the OC-N facility that serves as the working facility for the protection group. Currently, only OCN-N facilities that are OTU-N mapped are supported for protection grouping. |
| INT ocnProtGrpWorkShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.2 | INTEGER | not-accessible | The number of the shelf of the OC-N facility that serves as the working facility for the protection group. |
| INT ocnProtGrpWorkSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.3 | INTEGER | not-accessible | The number of the slot of the OC-N facility that serves as the working facility for the protection group. |
| INT ocnProtGrpWorkPortIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.4 | INTEGER | not-accessible | The number of the port of the OC-N facility that serves as the working facility for the protection group. |
| OCN ocnProtGrpProtTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.5 | OcnType | not-accessible | The specific rate of the OC-N facility that serves as the protection facility for the protection group. Currently, only OC-N facilities that are OTU-N mapped are supported for protection grouping. |
| INT ocnProtGrpProtShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.6 | INTEGER | not-accessible | The number of the shelf of the OC-N facility that serves as the protection facility for the protection group. |
| INT ocnProtGrpProtSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.7 | INTEGER | not-accessible | The number of the slot of the OC-N facility that serves as the protection facility for the protection group. |
| INT ocnProtGrpProtPortIdx | 1.3.6.1.4.1.18070.2.2.1.10.2.1.8 | INTEGER | not-accessible | The number of the port of the OC-N facility that serves as the protection facility for the protection group. |
| STR ocnProtGrpId | 1.3.6.1.4.1.18070.2.2.1.10.2.1.9 | DisplayString | read-create | Textual data recorded by the user to describe the provisioned OC-N protection group in a manner useful to the user. |
| ROW ocnProtGrpRowStatus | 1.3.6.1.4.1.18070.2.2.1.10.2.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the OC-N protection group table, which in turn controls provisioning and deprovisioning of OC-N facility protection groups. |
| stmnProtGrpTable | 1.3.6.1.4.1.18070.2.2.1.10.3 | not-accessible | This table contains one row for every provisioned protection group pairing between SDH STM-N facilities on Muxponder circuit packs. | |
| stmnProtGrpEntry | 1.3.6.1.4.1.18070.2.2.1.10.3.1 | not-accessible | The conceptual row object of the STM-N facility protection group table. | |
| STM stmnProtGrpWorkTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.1 | StmnType | not-accessible | The specific rate of the STM-N facility that serves as the working facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping. |
| INT stmnProtGrpWorkShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.2 | INTEGER | not-accessible | The number of the shelf of the STM-N facility that serves as the working facility for the protection group. |
| INT stmnProtGrpWorkSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.3 | INTEGER | not-accessible | The number of the slot of the STM-N facility that serves as the working facility for the protection group. |
| INT stmnProtGrpWorkPortIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.4 | INTEGER | not-accessible | The number of the port of the STM-N facility that serves as the working facility for the protection group. |
| STM stmnProtGrpProtTypeIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.5 | StmnType | not-accessible | The specific rate of the STM-N facility that serves as the protection facility for the protection group. Currently, only STM-N facilities that are OTU-N mapped are supported for protection grouping. |
| INT stmnProtGrpProtShelfIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.6 | INTEGER | not-accessible | The number of the shelf of the STM-N facility that serves as the protection facility for the protection group. |
| INT stmnProtGrpProtSlotIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.7 | INTEGER | not-accessible | The number of the slot of the STM-N facility that serves as the protection facility for the protection group. |
| INT stmnProtGrpProtPortIdx | 1.3.6.1.4.1.18070.2.2.1.10.3.1.8 | INTEGER | not-accessible | The number of the port of the STM-N facility that serves as the protection facility for the protection group. |
| STR stmnProtGrpId | 1.3.6.1.4.1.18070.2.2.1.10.3.1.9 | DisplayString | read-create | Textual data recorded by the user to describe the provisioned STM-N protection group in a manner useful to the user. |
| ROW stmnProtGrpRowStatus | 1.3.6.1.4.1.18070.2.2.1.10.3.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the STM-N protection group table, which in turn controls provisioning and deprovisioning of STM-N facility protection groups. |
| operations | 1.3.6.1.4.1.18070.2.2.1.11 | |||
| neOperations | 1.3.6.1.4.1.18070.2.2.1.11.1 | |||
| dbBackupAndRestore | 1.3.6.1.4.1.18070.2.2.1.11.1.1 | |||
| DBB dbBackupAndRestoreCmd | 1.3.6.1.4.1.18070.2.2.1.11.1.1.1 | DbBackupAndRestoreCmd | read-write | This object is used to activate the steps of a database backup or database restore operation. The description of the DbBackupAndRestoreCmd textual convention explains the usage of this object to perform these operations. |
| DBB dbBackupAndRestoreType | 1.3.6.1.4.1.18070.2.2.1.11.1.1.2 | DbBackupAndRestoreType | read-write | This object is used to indicate whether a local database, or a remote database is involved in the backup or restore operation that is being activated with the dbBackupAndRestoreCmd object, as explained in the DbBackupAndRestoreType textual convention. |
| IP dbBackupAndRestoreAddress | 1.3.6.1.4.1.18070.2.2.1.11.1.1.3 | IpAddress | read-write | The IP address of an ftp server which the NE database is backed up to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. |
| STR dbBackupAndRestorePath | 1.3.6.1.4.1.18070.2.2.1.11.1.1.4 | DisplayString | read-write | The directory path on the ftp server where where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. |
| STR dbBackupAndRestoreFtpUser | 1.3.6.1.4.1.18070.2.2.1.11.1.1.5 | DisplayString | read-write | The user identifier to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. |
| STR dbBackupAndRestoreFtpPswd | 1.3.6.1.4.1.18070.2.2.1.11.1.1.6 | DisplayString | read-write | The password to be used on the ftp server where the NE database backup is to be saved to, or restored from. This object is used when the dbBackupAndRestoreType is set to remote. |
| INT dbBackupAndRestoreCheckAlm | 1.3.6.1.4.1.18070.2.2.1.11.1.1.7 | INTEGER | read-write | This object is used to indicate whether or not the system is to be checked for active alarms before proceding with a backup or restore operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes. |
| INT dbBackupAndRestoreCheckSysName | 1.3.6.1.4.1.18070.2.2.1.11.1.1.8 | INTEGER | read-write | This object is used to indicate whether or not the system name of the NE targeted for a database restore operation against the system name embedded in the database backup file to be restored. If set to yes, the requested action will not be performed if system names do not match. If not specified in the same set request as the dbBackupAndRestoreCmd object, the value is defaulted to yes. |
| STR dbBackupAndRestoreInvokeFilename | 1.3.6.1.4.1.18070.2.2.1.11.1.1.9 | DisplayString | read-write | The name of the database backup file that is to be used in a database restore operation. This object is set along with the dbBackupAndRestoreCmd object when it is set to invokeRestore, as a confirmation that the database that is to be restored is the correct database. In order for the invokeRestore command to proceed, the value set for this object must match the value of the dbBackupAndRestoreFilename object. |
| STR dbBackupAndRestoreFilename | 1.3.6.1.4.1.18070.2.2.1.11.1.1.10 | DisplayString | read-only | The name of the database backup file that is present and ready to be restored. The value of this field is valid after the completion of the loadRestore command. |
| INT dbBackupAndRestoreResult | 1.3.6.1.4.1.18070.2.2.1.11.1.1.11 | INTEGER | accessible-for-notify | Indicates if the identified stage of the database backup and restore process has resulted in success or failure. |
| swUpgrade | 1.3.6.1.4.1.18070.2.2.1.11.1.2 | |||
| SWU swUpgradeCmd | 1.3.6.1.4.1.18070.2.2.1.11.1.2.1 | SwUpgradeCmd | read-write | This object is used to activate the steps of a software upgrade procedure on the system. The description of the SwUpgradeCmd textual convention explains the usage of this object to perform these operations. |
| IP swUpgradeAddress | 1.3.6.1.4.1.18070.2.2.1.11.1.2.2 | IpAddress | read-write | The IP address of an ftp or sftp server from which the software load files for the upgrade are to be downloaded. |
| STR swUpgradePath | 1.3.6.1.4.1.18070.2.2.1.11.1.2.3 | DisplayString | read-write | The directory path on the upgrade load files ftp or sftp server where the software load files are found. |
| STR swUpgradeFtpUser | 1.3.6.1.4.1.18070.2.2.1.11.1.2.4 | DisplayString | read-write | The user identifier to be used on the ftp or sftp server from which the upgrade load is downloaded. |
| STR swUpgradeFtpPswd | 1.3.6.1.4.1.18070.2.2.1.11.1.2.5 | DisplayString | read-write | The password to be used on the ftp or sftp server from which the upgrade load is downloaded. |
| STR swUpgradeInvokeRelNum | 1.3.6.1.4.1.18070.2.2.1.11.1.2.6 | DisplayString | read-write | The release number of the software upgrade load that is targeted in a software upgrade invoke operation. This object must be set along with the swUpgradeCmd object when it is set to invokeUpgrade or invokeScpUpgrade, as a confirmation that the software load to be used in the upgrade is the correct load. |
| INT swUpgradeCheckAlm | 1.3.6.1.4.1.18070.2.2.1.11.1.2.7 | INTEGER | read-write | This object is used to indicate whether or not the system is to be checked for active alarms before proceding with a software upgrade operation. If set to yes, the requested action will not be performed if alarms are active on the system. If not specified in the same set request as the swUpgradeCmd object, the value is defaulted to yes. |
| STR swUpgradeActiveRelNum | 1.3.6.1.4.1.18070.2.2.1.11.1.2.8 | DisplayString | read-only | The release number of the software load that is installed on the system and is currently active. |
| STR swUpgradeInactiveRelNum | 1.3.6.1.4.1.18070.2.2.1.11.1.2.9 | DisplayString | read-only | The release number of the software load that is installed on the system and is currently inactive. |
| SWU swUpgradeFileTransferType | 1.3.6.1.4.1.18070.2.2.1.11.1.2.10 | SwUpgradeFileTransferType | read-write | This object is used to define the file transfer protocol used to retreive the load from a remote server. The default value is ftp |
| shelfInvOperations | 1.3.6.1.4.1.18070.2.2.1.11.2 | |||
| slotInvOperations | 1.3.6.1.4.1.18070.2.2.1.11.3 | |||
| shelfOperations | 1.3.6.1.4.1.18070.2.2.1.11.4 | |||
| cpOperations | 1.3.6.1.4.1.18070.2.2.1.11.5 | |||
| cpRestartOpTable | 1.3.6.1.4.1.18070.2.2.1.11.5.1 | not-accessible | This table contains one row for every provisioned restartable circuit pack on the NE to facilitate the performing of circuit pack restarts. | |
| cpRestartOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1 | not-accessible | The conceptual row object of the circuit pack restart operation table. | |
| CPT cpRestartOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.1 | CpType | not-accessible | The specific type of circuit pack targeted for the restart operation. |
| INT cpRestartOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.2 | INTEGER | not-accessible | The number of the shelf on which the circuit pack targeted for the restart operation is provisioned. |
| INT cpRestartOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.3 | INTEGER | not-accessible | The number of the slot in which the circuit pack targeted for the restart operation is provisioned. For ESI type circuit packs, the slot will be 0. For CCM type circuit packs, the slot can only be 1 or 2. |
| INT cpRestartOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.5.1.1.4 | INTEGER | read-write | Used to perform a circuit pack restart operation as follows. - warmRestart causes a restart of the main processor only; traffic is not affected - coldRestart causes a full circuit pack restart, including data path - powerOn causes a circuit pack that has been powered down due to a high temperature or voltage event to power on. When this object is read, the value noOp is returned. |
| oaOperations | 1.3.6.1.4.1.18070.2.2.1.11.6 | |||
| oaOOBRSDOpTable | 1.3.6.1.4.1.18070.2.2.1.11.6.1 | not-accessible | This table contains one row for every provisioned optical amplifier on the NE that supports the Override Optical Back Reflection Shutdown operation. | |
| oaOOBRSDOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1 | not-accessible | The conceptual row object of the optical amplifier override optical back reflection shutdown operation table. | |
| OAT oaOOBRSDOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.1 | OaType | not-accessible | The specific type of optical amplifier. |
| INT oaOOBRSDOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.2 | INTEGER | not-accessible | The number of the shelf on which the optical amplifier targeted for the operation is provisioned. |
| INT oaOOBRSDOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.3 | INTEGER | not-accessible | The number of the slot within which the optical amplifier facility targeted for the operation is provisioned. |
| INT oaOOBRSDOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the optical amplifier facility has been provisioned. |
| INT oaOOBRSDOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.5 | INTEGER | read-write | Used to perform a Override Optical Back Reflection Shutdown operation when this object is set to overrideOBRSD. When read, this object returns noOp. |
| INT oaOOBRSDOpTimer | 1.3.6.1.4.1.18070.2.2.1.11.6.1.1.6 | INTEGER | read-write | Used to specify the time duration of an override back reflection shutdown operation. It is only valid to set the value of this object in the same set request as for the oaOOBRSDOpCmd object. Despite the indicated value range, the actual supported range is 20 to 600. The value 0 is returned when this object is read, even if an overrideOBRSD operation is in progress. |
| dataCommsOperations | 1.3.6.1.4.1.18070.2.2.1.11.7 | |||
| dataCommsPingTable | 1.3.6.1.4.1.18070.2.2.1.11.7.1 | not-accessible | This table contains one row for every provisioned circuit pack on the NE from which an IP ping request can be sent. This includes all SCP and OSC type packs. | |
| dataCommsPingEntry | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1 | not-accessible | The conceptual row object of the data comms ping table. | |
| CPT dataCommsPingCpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.1 | CpType | not-accessible | This object is used to indicate the type of circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. |
| INT dataCommsPingShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.2 | INTEGER | not-accessible | This object is used to indicate the shelf number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. |
| INT dataCommsPingSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.3 | INTEGER | not-accessible | This object is used to indicate the slot number containing the circuit pack from which the ping operation is to be conducted using the dataCommsPingCmd object. |
| DAT dataCommsPingCmd | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.4 | DataCommsPingCmd | read-write | This object is used to trigger a ping operation from an OSC or SCP circuit pack. The description of DataCommsPingCmd textual convention explains the usage of this object to perform the ping operation. |
| IP dataCommsPingAddress | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.5 | IpAddress | read-write | This object is used to indicate the IP Address which is the target of the ping operation to be conducted using the dataCommsPingCmd object. |
| INT dataCommsPingNumAttempts | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.6 | INTEGER | read-write | This object is used to indicate how many ping attempts are to be made in the ping operation to be conducted using the dataCommsPingCmd object. The default is 3. |
| INT dataCommsPingNumSuccesses | 1.3.6.1.4.1.18070.2.2.1.11.7.1.1.7 | INTEGER | read-only | This object is used to indicate how many ping trials attempted in the ping operation resulted in a successful ping completion. |
| pluggableInvOperations | 1.3.6.1.4.1.18070.2.2.1.11.8 | |||
| pluggableInvRestartOpTable | 1.3.6.1.4.1.18070.2.2.1.11.8.1 | not-accessible | This table contains one row for every provisioned restartable pluggable on a circuit pack. | |
| pluggableInvRestartOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1 | not-accessible | The conceptual row object of the pluggable restart operation table. | |
| INT pluggableInvRestartOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.1 | INTEGER | not-accessible | The type of small form-factor pluggable inventory item targeted for the restart operation. |
| INT pluggableInvRestartOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.2 | INTEGER | not-accessible | The number of the shelf on which the pluggable inventory item resides targeted for the restart operation is provisioned. |
| INT pluggableInvRestartOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.3 | INTEGER | not-accessible | The number of the slot that contains the pluggable inventory item targeted for the restart operation is provisioned. |
| INT pluggableInvRestartOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack that contains the pluggable inventory item. |
| INT pluggableInvRestartOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.8.1.1.5 | INTEGER | read-write | Used to perform a restart operation as follows. - coldRestart causes a pluggable restart When this object is read, the value noOp is returned. |
| xcvrOperations | 1.3.6.1.4.1.18070.2.2.1.11.9 | |||
| xcvrLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.9.1 | not-accessible | This table contains one row for every provisioned optical transceiver on the NE to facilitate the performing of transceiver loopback operations. | |
| xcvrLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1 | not-accessible | The conceptual row object of the optical transceiver loopback operation table. | |
| XCV xcvrLpbkOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.1 | XcvrType | not-accessible | The specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the loopback operation. |
| INT xcvrLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.2 | INTEGER | not-accessible | The number of the shelf of the transceiver targeted for the loopback operation. |
| INT xcvrLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.3 | INTEGER | not-accessible | The number of the slot in which the transceiver targeted for the loopback operation is provisioned. |
| INT xcvrLpbkOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the optical transceiver facility has been provisioned. |
| INT xcvrLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.9.1.1.5 | INTEGER | read-write | Used to perform a loopback operation on a transceiver facility as follows: - oprLpbk: operates a loopback on the transceiver - rlsLpbk: causes a previously invoked loopback to be released - oprTermLpbk: operates a terminal loopback for the transceiver When read, this object returns noOp. |
| xcvrProtSwOpTable | 1.3.6.1.4.1.18070.2.2.1.11.9.2 | not-accessible | This table contains one row for every provisioned optical transceiver on the NE configured to be part of a protection group pair to facilitate the performing of transceiver protection switching operations. | |
| xcvrProtSwOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1 | not-accessible | The conceptual row object of the optical transceiver protection switching operation table. | |
| XCV xcvrProtSwOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.1 | XcvrType | not-accessible | The specific type of wavelength conversion function of the circuit pack of the transceiver port targeted for the protection switching operation. |
| INT xcvrProtSwOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.2 | INTEGER | not-accessible | The number of the shelf of the transceiver targeted for the protection switching operation. |
| INT xcvrProtSwOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.3 | INTEGER | not-accessible | The number of the slot within which the transceiver targeted for the protection switching operation is provisioned. |
| INT xcvrProtSwOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the optical transceiver facility has been provisioned. |
| PRO xcvrProtSwOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.9.2.1.5 | ProtSwOpCmd | read-write | Used to perform a protection switch on a transceiver facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. |
| adminOperations | 1.3.6.1.4.1.18070.2.2.1.11.10 | |||
| amdOperations | 1.3.6.1.4.1.18070.2.2.1.11.11 | |||
| ocnOperations | 1.3.6.1.4.1.18070.2.2.1.11.12 | |||
| ocnLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.12.1 | not-accessible | This table contains one row for every provisioned OC-N facility on the NE to facilitate the performing loopback operations. | |
| ocnLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1 | not-accessible | The conceptual row object of the OC-N loopback operation table. | |
| OCN ocnLpbkOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.1 | OcnType | not-accessible | The specific type of OC-N signal which is targeted for the loopback operation. |
| INT ocnLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.2 | INTEGER | not-accessible | The number of the shelf of the OC-N facility targeted for the loopback operation. |
| INT ocnLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.3 | INTEGER | not-accessible | The number of the slot in which the OC-N facility targeted for the loopback operation is provisioned. |
| INT ocnLpbkOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the OC-N facility targeted for the loopback operation is provisioned. |
| INT ocnLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.12.1.1.5 | INTEGER | read-write | Used to perform a loopback operation on a OC-N facility as follows: - oprFacilityLpbk: operates an OC-N facility loopback - oprTerminalLpbk: operates an OC-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that the terminal loopback can only be operated on a client OC-N facility. When read, this object returns noOp. |
| ocnProtSwOpTable | 1.3.6.1.4.1.18070.2.2.1.11.12.2 | not-accessible | This table contains one row for every provisioned SONET OC-N facility on the NE configured to be part of a protection group pair to facilitate the performing of OC-N line protection switching operations. | |
| ocnProtSwOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1 | not-accessible | The conceptual row object of the SONET OC-N facility protection switching operation table. | |
| OCN ocnProtSwOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.1 | OcnType | not-accessible | The specific rate of OC-N facility targeted for the protection switching operation. |
| INT ocnProtSwOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.2 | INTEGER | not-accessible | The number of the shelf of the OC-N facility targeted for the protection switching operation. |
| INT ocnProtSwOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.3 | INTEGER | not-accessible | The number of the slot within which the OC-N facility targeted for the protection switching operation is provisioned. |
| INT ocnProtSwOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the OC-N facility has been provisioned. |
| PRO ocnProtSwOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.12.2.1.5 | ProtSwOpCmd | read-write | Used to perform a protection switch on a OC-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. |
| stsnOperations | 1.3.6.1.4.1.18070.2.2.1.11.13 | |||
| stsnProtSwOpTable | 1.3.6.1.4.1.18070.2.2.1.11.13.1 | not-accessible | This table contains one row for every created SONET STS-N facility on the system which is part of a protection group pairing to facilitate the performing of STS-N protection switching operations. | |
| stsnProtSwOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1 | not-accessible | The conceptual row object of the SONET STS-N protection switching operation table. | |
| STS stsnProtSwOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.1 | StsnType | not-accessible | The specific type of STS-N signal targeted for the protection switching operation. |
| INT stsnProtSwOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.2 | INTEGER | not-accessible | The number of the shelf of the STS-N facility targeted for the protection switching operation. |
| INT stsnProtSwOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.3 | INTEGER | not-accessible | The number of the slot of the STS-N facility targeted for the protection switching operation. |
| INT stsnProtSwOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.4 | INTEGER | not-accessible | The number of the port of the STS-N facility targeted for the protection switching operation. |
| INT stsnProtSwOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.5 | INTEGER | not-accessible | The sts channel number of the STS-N facility targeted for the protection switching operation. |
| PRO stsnProtSwOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.13.1.1.6 | ProtSwOpCmd | read-write | Used to perform a protection switch on a STS-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention. |
| stmnOperations | 1.3.6.1.4.1.18070.2.2.1.11.14 | |||
| stmnLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.14.1 | not-accessible | This table contains one row for every provisioned STM-N facility on the NE to facilitate the performing of STM-N facility loopback operations. | |
| stmnLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1 | not-accessible | The conceptual row object of the STM-N loopback operation table. | |
| STM stmnLpbkOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.1 | StmnType | not-accessible | The specific type of STM-N signal which is targeted for the loopback operation. |
| INT stmnLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.2 | INTEGER | not-accessible | The number of the shelf of the STM-N facility targeted for the loopback operation. |
| INT stmnLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.3 | INTEGER | not-accessible | The number of the slot in which the STM-N facility targeted for the loopback operation is provisioned. |
| INT stmnLpbkOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the STM-N facility targeted for the loopback operation is provisioned. |
| INT stmnLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.14.1.1.5 | INTEGER | read-write | Used to perform a loopback operation on a STM-N facility as follows: - oprFacilityLpbk: operates an STM-N facility loopback - oprTerminalLpbk: operates an STM-N terminal loopback - rlsLpbk: releases a previously invoked loopback Note that a terminal loopback can only be operated on a client STM-N facility. When read, this object returns noOp. |
| stmnProtSwOpTable | 1.3.6.1.4.1.18070.2.2.1.11.14.2 | not-accessible | This table contains one row for every provisioned SDH STM-N facility on the NE configured to be part of a protection group pair to facilitate the performing of STM-N line protection switching operations. | |
| stmnProtSwOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1 | not-accessible | The conceptual row object of the SDH STM-N facility protection switching operation table. | |
| STM stmnProtSwOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.1 | StmnType | not-accessible | The specific rate of STM-N facility targeted for the protection switching operation. |
| INT stmnProtSwOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.2 | INTEGER | not-accessible | The number of the shelf of the STM-N faacility targeted for the protection switching operation. |
| INT stmnProtSwOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.3 | INTEGER | not-accessible | The number of the slot within which the STM-N facility targeted for the protection switching operation is provisioned. |
| INT stmnProtSwOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.4 | INTEGER | not-accessible | The number of the port on the circuit pack on which the STM-N facility has been provisioned. |
| PRO stmnProtSwOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.14.2.1.5 | ProtSwOpCmd | read-write | Used to perform a protection switch on a STM-N facility which is configured to be a part of a protection group, as described in the ProtSwOpCmd textual convention. |
| vcnOperations | 1.3.6.1.4.1.18070.2.2.1.11.15 | |||
| vcnProtSwOpTable | 1.3.6.1.4.1.18070.2.2.1.11.15.1 | not-accessible | This table contains one row for every created SDH VC-N facility on the system which is part of a protection group pairing to facilitate the performing of VC-N protection switching operations. | |
| vcnProtSwOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1 | not-accessible | The conceptual row object of the SDH VC-N protection switching operation table. | |
| VCN vcnProtSwOpTypeIdx | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.1 | VcnType | not-accessible | The specific type of VC-N signal targeted for the protection switching operation. |
| INT vcnProtSwOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.2 | INTEGER | not-accessible | The number of the shelf of the VC-N facility targeted for the protection switching operation. |
| INT vcnProtSwOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.3 | INTEGER | not-accessible | The number of the slot of the VC-N facility targeted for the protection switching operation. |
| INT vcnProtSwOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.4 | INTEGER | not-accessible | The number of the port of the VC-N facility targeted for the protection switching operation. |
| INT vcnProtSwOpIdx | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.5 | INTEGER | not-accessible | The index number of the VC-N facility targeted for the protection switching operation. |
| PRO vcnProtSwOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.15.1.1.6 | ProtSwOpCmd | read-write | Used to perform a protection switch on a VC-N facility which is part of a protection group pairing, as described in the ProtSwOpCmd textual convention. |
| geOperations | 1.3.6.1.4.1.18070.2.2.1.11.16 | |||
| geLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.16.1 | not-accessible | This table contains one row for every provisioned Gigabit Ethernet facility on the NE to facilitate the performing of GE facility loopback operations. | |
| geLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1 | not-accessible | The conceptual row object of the Gigabit Ethernet loopback operation table. | |
| INT geLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.1 | INTEGER | not-accessible | The number of the shelf of the Gigabit Ethernet facility targeted for the loopback operation. |
| INT geLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.2 | INTEGER | not-accessible | The number of the slot in which the Gigabit Ethernet facility targeted for the loopback operation is provisioned. |
| INT geLpbkOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.3 | INTEGER | not-accessible | The number of the port on the circuit pack on which the Gigabit Ethernet facility targeted for the loopback operation is provisioned. |
| INT geLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.16.1.1.4 | INTEGER | read-write | Used to perform a loopback operation on a Gigabit Ethernet facility as follows: - oprFacilityLpbk: operates an GE facility loopback - oprFacilityLpbk: operates an GE terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. |
| fcOperations | 1.3.6.1.4.1.18070.2.2.1.11.17 | |||
| fcLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.17.1 | not-accessible | This table contains one row for every provisioned Fiber Channel facility on the NE to facilitate the performing of FC facility loopback operations. | |
| fcLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1 | not-accessible | The conceptual row object of the Fiber Channel loopback operation table. | |
| INT fcLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.1 | INTEGER | not-accessible | The number of the shelf of the Fiber Channel facility targeted for the loopback operation. |
| INT fcLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.2 | INTEGER | not-accessible | The number of the slot in which the Fiber Channel facility targeted for the loopback operation is provisioned. |
| INT fcLpbkOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.3 | INTEGER | not-accessible | The number of the port on the circuit pack on which the Fiber Channel facility targeted for the loopback operation is provisioned. |
| INT fcLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.17.1.1.4 | INTEGER | read-write | Used to perform a loopback operation on a Fiber Channel facility as follows: - oprFacilityLpbk: operates an FC facility loopback - oprFacilityLpbk: operates an FC terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. |
| briOperations | 1.3.6.1.4.1.18070.2.2.1.11.18 | |||
| briLpbkOpTable | 1.3.6.1.4.1.18070.2.2.1.11.18.1 | not-accessible | This table contains one row for every provisioned Bit Rate Independent (BRI) facility on the NE to facilitate the performing of BRI facility loopback operations. | |
| briLpbkOpEntry | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1 | not-accessible | The conceptual row object of the BRI loopback operation table. | |
| INT briLpbkOpShelfIdx | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.1 | INTEGER | not-accessible | The number of the shelf of the BRI facility targeted for the loopback operation. |
| INT briLpbkOpSlotIdx | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.2 | INTEGER | not-accessible | The number of the slot in which the BRI facility targeted for the loopback operation is provisioned. |
| INT briLpbkOpPortIdx | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.3 | INTEGER | not-accessible | The number of the port on the circuit pack on which the BRI facility targeted for the loopback operation is provisioned. |
| INT briLpbkOpCmd | 1.3.6.1.4.1.18070.2.2.1.11.18.1.1.4 | INTEGER | read-write | Used to perform a loopback operation on a BRI facility as follows: - oprFacilityLpbk: operates a BRI facility loopback - oprFacilityLpbk: operates a BRI terminal loopback - rlsLpbk: releases a previously invoked loopback When read, this object returns noOp. |
| synchronization | 1.3.6.1.4.1.18070.2.2.1.12 | |||
| cpSynchronizationTable | 1.3.6.1.4.1.18070.2.2.1.12.1 | not-accessible | This table contains one row for every provisioned circuit pack that supports SONET synchronization configuration. | |
| cpSynchronizationEntry | 1.3.6.1.4.1.18070.2.2.1.12.1.1 | not-accessible | The conceptual row object of the circuit pack synchronization table. | |
| CPT cpSynchronizationTypeIdx | 1.3.6.1.4.1.18070.2.2.1.12.1.1.1 | CpType | not-accessible | The specific type of circuit pack provisioned. |
| INT cpSynchronizationShelfIdx | 1.3.6.1.4.1.18070.2.2.1.12.1.1.2 | INTEGER | not-accessible | The number of the shelf on which the circuit pack is provisioned. |
| INT cpSynchronizationSlotIdx | 1.3.6.1.4.1.18070.2.2.1.12.1.1.3 | INTEGER | not-accessible | The number of the slot in which the circuit pack is provisioned. |
| INT cpSynchronizationTimingMode | 1.3.6.1.4.1.18070.2.2.1.12.1.1.4 | INTEGER | read-write | The timing mode used for SONET synchronization on the pack. |
| INT cpSynchronizationPrimRefSrcPortNum | 1.3.6.1.4.1.18070.2.2.1.12.1.1.5 | INTEGER | read-write | The port number of the SONET facility that serves as the primary timing reference source. When the value is 0, the primary reference is not configured. |
| PRO cpSynchronizationPrimRefProtStatus | 1.3.6.1.4.1.18070.2.2.1.12.1.1.6 | ProtectionStatusType | read-only | The protection status of the primary timing reference source. |
| OPE cpSynchronizationPrimProtStatQlfr | 1.3.6.1.4.1.18070.2.2.1.12.1.1.7 | OperStatQlfr | read-only | A textual list of qualifiers of the reported protection status of the primary timing reference source. |
| INT cpSynchronizationSecRefSrcPortNum | 1.3.6.1.4.1.18070.2.2.1.12.1.1.8 | INTEGER | read-write | The port number of the SONET facility that serves as the secondary timing reference source. When the value is 0, the secondary reference is not configured. |
| PRO cpSynchronizationSecRefProtStatus | 1.3.6.1.4.1.18070.2.2.1.12.1.1.9 | ProtectionStatusType | read-only | The protection status of the secondary timing reference source. |
| OPE cpSynchronizationSecProtStatQlfr | 1.3.6.1.4.1.18070.2.2.1.12.1.1.10 | OperStatQlfr | read-only | A textual list of qualifiers of the reported protection status of the secondary timing reference source. |
| INT cpSynchronizationPrimRefBasicSSM | 1.3.6.1.4.1.18070.2.2.1.12.1.1.11 | INTEGER | read-write | Used to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source. |
| INT cpSynchronizationSecRefBasicSSM | 1.3.6.1.4.1.18070.2.2.1.12.1.1.12 | INTEGER | read-write | Used to enable basic Synchronization Status Messaging (SSM) functionality on the primary timing reference source. |
| SYN cpSynchronizationSwEvtType | 1.3.6.1.4.1.18070.2.2.1.12.1.1.13 | SyncSwEvtType | accessible-for-notify | Indicates the type of timing reference switching event that has occurred on the circuit pack. |
| topology | 1.3.6.1.4.1.18070.2.2.1.13 | |||
| networkNeighborTable | 1.3.6.1.4.1.18070.2.2.1.13.1 | not-accessible | This table is used to store information on the network neighbors of the local network element. Each row contains information on a specific network neighbor. | |
| networkNeighborEntry | 1.3.6.1.4.1.18070.2.2.1.13.1.1 | not-accessible | The conceptual row object of the network neighbor table. | |
| STR networkNeighborIdx | 1.3.6.1.4.1.18070.2.2.1.13.1.1.1 | DisplayString | not-accessible | A textual identifier of the network neighbor. |
| IP networkNeighborIPAddr | 1.3.6.1.4.1.18070.2.2.1.13.1.1.2 | IpAddress | read-create | The primary IP Address of the network neighbor. |
| ROW networkNeighborRowStatus | 1.3.6.1.4.1.18070.2.2.1.13.1.1.3 | RowStatus | read-create | Used to control the addition and deletion of entries in the network neighbor table. |
| ospfGeneralTable | 1.3.6.1.4.1.18070.2.2.1.13.2 | not-accessible | This table contains all of general OSPF parameters for the network element. The group can be created and deleted but only one entry can exist in the table. | |
| ospfGeneralGroupEntry | 1.3.6.1.4.1.18070.2.2.1.13.2.1 | not-accessible | The list entry for the OSPF General Group parameters. | |
| INT ospfIdx | 1.3.6.1.4.1.18070.2.2.1.13.2.1.1 | INTEGER | not-accessible | An index used to identify the OSPF instance in order to alow for creation and deletion to allow compatibility with TL1 and CLI interfaces. Note the value is always 1. |
| IP ospfRouterId | 1.3.6.1.4.1.18070.2.2.1.13.2.1.2 | IpAddress | read-create | A 32-bit integer uniquely identifying the router. By convention, to ensure uniqueness, this should default to the value of one of the router's IP interface addresses. This object is persistent. |
| INT ospfAdminStat | 1.3.6.1.4.1.18070.2.2.1.13.2.1.3 | INTEGER | read-create | The administrative status of OSPF in the router. The value 'enabled' denotes that the OSPF Process is active on at least one interface; 'disabled' disables it on all interfaces. This object is persistent. |
| INT ospfVersionNumber | 1.3.6.1.4.1.18070.2.2.1.13.2.1.4 | INTEGER | read-only | The current version number of the OSPF protocol is 2. |
| T/F ospfAreaBdrRtrStatus | 1.3.6.1.4.1.18070.2.2.1.13.2.1.5 | TruthValue | read-only | A flag to note whether this router is an Area Border Router. |
| INT ospfRouteRedist | 1.3.6.1.4.1.18070.2.2.1.13.2.1.6 | INTEGER | read-create | Indicates the extent of route redistribution. Static - static routes, Connected - routes connected to the node. DefOrig - default routes from adjacent nodes. |
| IP ospfAreaId | 1.3.6.1.4.1.18070.2.2.1.13.2.1.7 | IpAddress | read-create | The area ID associated with this OSPF item. Note that although the area ID has the format of an IP Address it is not actually an IP address. |
| ROW ospfRowStatus | 1.3.6.1.4.1.18070.2.2.1.13.2.1.8 | RowStatus | read-create | Used to control the addition and deletion of the ospf General Group parameters. |
| ospfIfTable | 1.3.6.1.4.1.18070.2.2.1.13.3 | not-accessible | The OSPF Interface Table describes the interfaces from the viewpoint of OSPF. | |
| ospfIfEntry | 1.3.6.1.4.1.18070.2.2.1.13.3.1 | not-accessible | The OSPF interface entry describes one interface from the viewpoint of OSPF. Information in this table is persistent and when this object is written the entity is saved to non-volatile storage. | |
| INT ospfIfSwitchId | 1.3.6.1.4.1.18070.2.2.1.13.3.1.1 | INTEGER | accessible-for-notify | The number of the switch id on which the OSPF interface exists. Set to zero if the switchId a switch Id is not applicable for identification of the OSPF interface. |
| INT ospfIfShelfIdx | 1.3.6.1.4.1.18070.2.2.1.13.3.1.2 | INTEGER | accessible-for-notify | The number of the shelf on which the OSPF interface exists. |
| INT ospfIfSlotIdx | 1.3.6.1.4.1.18070.2.2.1.13.3.1.3 | INTEGER | accessible-for-notify | The number of the slot within the shelf corresponding to the OSPF interface. |
| PVX ospfIfType | 1.3.6.1.4.1.18070.2.2.1.13.3.1.4 | PvxPortType | accessible-for-notify | The type of the interface corresponding to the OSPF interface. Set to zero if the ospfIfType is not applicable for identification of the OSPF interface. |
| INT ospfIfIdx | 1.3.6.1.4.1.18070.2.2.1.13.3.1.5 | INTEGER | accessible-for-notify | The number of the interface within the slot corresponding to the OSPF interface. |
| INT ospfIfSubIdx | 1.3.6.1.4.1.18070.2.2.1.13.3.1.6 | INTEGER | accessible-for-notify | The number of the sub-interface that the OSFP Interface corresponds to. Set to zero if the ospfIfSubIdx is not applicable for identification of the OSPF interface. |
| ARE ospfIfAreaId | 1.3.6.1.4.1.18070.2.2.1.13.3.1.7 | AreaID | read-only | A 32-bit integer uniquely identifying the area to which the interface connects. Area ID 0.0.0.0 is used for the OSPF backbone. |
| INT ospfIfAdminStat | 1.3.6.1.4.1.18070.2.2.1.13.3.1.8 | INTEGER | read-create | The OSPF interface's administrative status. The value formed on the interface, and the interface will be advertised as an internal route to some area. The value 'disabled' denotes that the interface is external to OSPF. |
| INT ospfIfRtrPriority | 1.3.6.1.4.1.18070.2.2.1.13.3.1.9 | INTEGER | read-create | The priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligible to become the designated router on this particular network. In the event of a tie in this value, routers will use their Router ID as a tie breaker. |
| INT ospfIfTransitDelay | 1.3.6.1.4.1.18070.2.2.1.13.3.1.10 | INTEGER | read-create | The estimated number of seconds it takes to transmit a link state update packet over this interface. Note that the minimal value SHOULD be 1 second. |
| INT ospfIfRetransInterval | 1.3.6.1.4.1.18070.2.2.1.13.3.1.11 | INTEGER | read-create | The number of seconds between link state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database description and Link State request packets. Note that minimal value SHOULD be 1 second. |
| INT ospfIfHelloInterval | 1.3.6.1.4.1.18070.2.2.1.13.3.1.12 | INTEGER | read-create | The length of time, in seconds, between the Hello packets that the router sends on the interface. This value must be the same for all routers attached to a common network. |
| INT ospfIfRtrDeadInterval | 1.3.6.1.4.1.18070.2.2.1.13.3.1.13 | INTEGER | read-create | The number of seconds that a router's Hello packets have not been seen before its neighbors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network. |
| INT ospfIfMetricValue | 1.3.6.1.4.1.18070.2.2.1.13.3.1.14 | INTEGER | read-create | A metric used to identify the 'cost' associated with using this interface. |
| ROW ospfIfStatus | 1.3.6.1.4.1.18070.2.2.1.13.3.1.15 | RowStatus | read-create | This object permits management of the table by facilitating actions such as row creation, construction, and destruction. The value of this object has no effect on whether other objects in this conceptual row can be modified. |
| ospfLsdbTable | 1.3.6.1.4.1.18070.2.2.1.13.4 | not-accessible | The OSPF Process's link state database (LSDB). The LSDB contains the link state advertisements from throughout the areas that the device is attached to. | |
| ospfLsdbEntry | 1.3.6.1.4.1.18070.2.2.1.13.4.1 | not-accessible | A single link state advertisement. | |
| ARE ospfLsdbAreaId | 1.3.6.1.4.1.18070.2.2.1.13.4.1.1 | AreaID | read-only | The 32-bit identifier of the area from which the LSA was received. |
| INT ospfLsdbType | 1.3.6.1.4.1.18070.2.2.1.13.4.1.2 | INTEGER | read-only | The type of the link state advertisement. Each link state type has a separate advertisement format |
| IP ospfLsdbLsid | 1.3.6.1.4.1.18070.2.2.1.13.4.1.3 | IpAddress | read-only | The Link State ID is an LS Type Specific field containing either a Router ID or an IP address; it identifies the piece of the routing domain that is being described by the advertisement. |
| IP ospfLsdbRouterId | 1.3.6.1.4.1.18070.2.2.1.13.4.1.4 | IpAddress | read-only | The 32-bit number that uniquely identifies the originating router in the Autonomous System. |
| I32 ospfLsdbSequence | 1.3.6.1.4.1.18070.2.2.1.13.4.1.5 | Integer32 | read-only | The sequence number field is a signed 32-bit integer. It starts with the value '80000001'h, or -'7FFFFFFF'h, and increments until '7FFFFFFF'h. Thus, a typical sequence number will be very negative. It is used to detect old and duplicate Link State Advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number, the more recent the advertisement. |
| I32 ospfLsdbAge | 1.3.6.1.4.1.18070.2.2.1.13.4.1.6 | Integer32 | read-only | This field is the age of the link state advertisement in seconds. |
| I32 ospfLsdbChecksum | 1.3.6.1.4.1.18070.2.2.1.13.4.1.7 | Integer32 | read-only | This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connectionless datagrams; it is commonly referred to as the Fletcher checksum. |
| ospfNbrTable | 1.3.6.1.4.1.18070.2.2.1.13.5 | not-accessible | A table describing all non-virtual neighbors in the locality of the OSPF router. | |
| ospfNbrEntry | 1.3.6.1.4.1.18070.2.2.1.13.5.1 | not-accessible | The information regarding a single neighbor. Information in this table is persistent and when this object is written the entity SHOULD save the change to non-volatile storage. | |
| IP ospfNbrIpAddr | 1.3.6.1.4.1.18070.2.2.1.13.5.1.1 | IpAddress | read-only | The IP address this neighbor is using in its IP source address. Note that, on addressless links, this will not be 0.0.0.0 but the address of another of the neighbor's interfaces. |
| I32 ospfNbrAddressLessIndex | 1.3.6.1.4.1.18070.2.2.1.13.5.1.2 | Integer32 | read-only | On an interface having an IP address, zero. On addressless interfaces, the corresponding value of ifIndex in the Internet Standard MIB. On row creation, this can be derived from the instance. |
| IP ospfNbrRtrId | 1.3.6.1.4.1.18070.2.2.1.13.5.1.3 | IpAddress | read-only | A 32-bit integer (represented as a type IpAddress) uniquely identifying the neighboring router in the Autonomous System. |
| I32 ospfNbrOptions | 1.3.6.1.4.1.18070.2.2.1.13.5.1.4 | Integer32 | read-only | A bit mask corresponding to the neighbor's options field. Bit 0, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric. Bit 1, if set, indicates that the associated area accepts and operates on external information; if zero, it is a stub area. Bit 2, if set, indicates that the system is capable of routing IP multicast datagrams, that is that it implements the multicast extensions to OSPF. Bit 3, if set, indicates that the associated area is an NSSA. These areas are capable of carrying type-7 external advertisements, which are translated into type-5 external advertisements at NSSA borders. |
| DES ospfNbrPriority | 1.3.6.1.4.1.18070.2.2.1.13.5.1.5 | DesignatedRouterPriority | read-only | The priority of this neighbor in the designated router election algorithm. The value 0 signifies that the neighbor is not eligible to become the designated router on this particular network. |
| INT ospfNbrState | 1.3.6.1.4.1.18070.2.2.1.13.5.1.6 | INTEGER | read-only | The state of the relationship with this neighbor. |
| pvxObjects | 1.3.6.1.4.1.18070.2.2.1.14 | |||
| pvxBridge | 1.3.6.1.4.1.18070.2.2.1.14.1 | |||
| pvxL2IntfTable | 1.3.6.1.4.1.18070.2.2.1.14.1.3 | not-accessible | This table contains one row for every provisioned Ethernet facility on the system. Each row contains a list of attributes that pertain to the facility. | |
| pvxL2IntfEntry | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1 | not-accessible | The conceptual row object of the ethIntfTable table. | |
| INT pvxL2IntfSwitchIdx | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.1 | INTEGER | accessible-for-notify | The number of the switch id of the provisioned ethernet facility. |
| INT pvxL2IntfShelfIdx | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.2 | INTEGER | accessible-for-notify | The number of the shelf id of the provisioned ethernet facility. |
| INT pvxL2IntfSlotIdx | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.3 | INTEGER | accessible-for-notify | The number of the instance id of the provisioned ethernet facility. |
| PVX pvxL2IntfPortTypeIdx | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.4 | PvxPortType | accessible-for-notify | The number of the instance id of the provisioned ethernet facility. |
| INT pvxL2IntfPortIdx | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.5 | INTEGER | accessible-for-notify | The number of the port on the circuit pack on which the ethernet facility is provisioned. |
| INT pvxL2IntfAdminStatus | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.6 | INTEGER | read-create | The administrative status of the Ethernet facility. |
| OPE pvxL2IntfOperStatus | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.7 | OperStatus | read-only | The reported operational status of the Ethernet facility. |
| INT pvxL2IntfType | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.8 | INTEGER | read-create | This object is used to configure the type of a interface. |
| INT pvxL2IntfSTpid | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.9 | INTEGER | read-create | The Ethernet type (TPID) of the S-TAG |
| INT pvxL2IntfPvid | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.10 | INTEGER | read-create | The PVID (port-based VLAN ID) for the port |
| INT pvxL2IntfDefaultPriority | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.11 | INTEGER | read-create | This object sets the default priority of the interface. |
| INT pvxL2IntfAllowedFrames | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.12 | INTEGER | read-create | TODO: Does this feild need to support OR of the options? |
| T/F pvxL2IntfIngressFiltering | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.13 | TruthValue | read-create | When this is true(1) the device will discard incoming frames for VLANs which do not include this Port in its Member set. When false(2), the port will accept all incoming frames. This control does not affect VLAN independent BPDU frames, such as GVRP and STP. It does affect VLAN dependent BPDU frames, such as GMRP. |
| I32 pvxL2IntfCtrlFrmProfileId | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.14 | Integer32 | read-create | |
| MAC pvxL2IntfMACAddr | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.15 | MacAddress | read-only | The MAC address of the interface. |
| I32 pvxL2IntfRateLimit | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.16 | Integer32 | read-create | This represents the interface rate limit in kilobits/s. |
| I32 pvxL2IntfCoSProfileId | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.17 | Integer32 | read-create | This represents the Class of service profile for the interface. |
| INT pvxL2IntfIsUNI | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.18 | INTEGER | read-only | The Switch port type. The default value set by the switch is neither. |
| STR pvxL2IntfSchedProfName | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.19 | DisplayString | read-create | The scheduler profile used by the interface. |
| STR pvxL2IntfPriTCMapProfName | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.20 | DisplayString | read-create | The priority to traffic class map profile used by the interface. |
| STR pvxL2IntfPCPCodingProfName | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.21 | DisplayString | read-create | The scheduler profile used by the interface. |
| STR pvxL2IntfDscpPHBProfName | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.22 | DisplayString | read-create | The internal priority setting for DSCP profile used by the interface. |
| STR pvxL2IntfCtrlFrmProfileName | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.23 | DisplayString | read-create | The L2 control frame profile used by the interface. |
| T/F pvxL2IntfUseDei | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.24 | TruthValue | read-create | Used by PNP port. By default, it is set to false by the switch. |
| STR pvxL2IntfIngressBandwidthProfile | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.25 | DisplayString | read-create | The ingress policy map profile used by the interface. |
| STR pvxL2IntfEgressBandwidthProfile | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.26 | DisplayString | read-create | The egress policy map profile used by the interface. |
| T/F pvxL2IntfTrustIncomingPCP | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.27 | TruthValue | read-create | Used by all port type. By default, it is set to true by the switch. |
| T/F pvxL2IntfTrustIncomingDscp | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.28 | TruthValue | read-create | Used by all port type. By default, it is set to true by the switch. |
| INT pvxL2IntfBcastLimit | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.29 | INTEGER | read-create | Broadcast rate limit as percentage of the line rate for the port with default value of 100 (no storm control). |
| INT pvxL2IntfMcastLimit | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.30 | INTEGER | read-create | Multicast rate limit as percentage of the line rate for the port with default value of 100 (no storm control). |
| INT pvxL2IntfDlfLimit | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.31 | INTEGER | read-create | Unicast DLF rate limit as percentage of the line rate for the port with default value of 100 (no storm control). |
| ROW pvxL2IntfRowStatus | 1.3.6.1.4.1.18070.2.2.1.14.1.3.1.100 | RowStatus | read-create | Used to control the addition and deletion of entries in the PVX L2 Interface table. |
| pvxNotificationObjects | 1.3.6.1.4.1.18070.2.2.1.14.4 | |||
| mstpNotificationObjects | 1.3.6.1.4.1.18070.2.2.1.14.4.1 | |||
| miscellaneous | 1.3.6.1.4.1.18070.2.2.1.15 | |||
| setErrorInfo | 1.3.6.1.4.1.18070.2.2.1.15.1 | |||
| I32 setErrorCode | 1.3.6.1.4.1.18070.2.2.1.15.1.1 | Integer32 | read-write | The BTI-specific error code for the set request failure. |
| STR setErrorDesc | 1.3.6.1.4.1.18070.2.2.1.15.1.2 | DisplayString | read-write | A textual description string that explains the reason for the failed set request. |
| opticalLayer | 1.3.6.1.4.1.18070.2.2.1.16 | |||
| notifications | 1.3.6.1.4.1.18070.2.2.2 | |||
| eventNotifications | 1.3.6.1.4.1.18070.2.2.2.1 | |||
| evtNotificationObjects | 1.3.6.1.4.1.18070.2.2.2.1.1 | |||
| DAT evtDateAndTime | 1.3.6.1.4.1.18070.2.2.2.1.1.1 | DateAndTime | accessible-for-notify | The date and time at which an event notification was issued by the system. |
| NUM tcaIntervalType | 1.3.6.1.4.1.18070.2.2.2.1.1.2 | PMIntervalType | accessible-for-notify | The type of PM bin according to interval length during which a performance monitoring threshold crossing occurred. |
| DAT tcaDateAndTime | 1.3.6.1.4.1.18070.2.2.2.1.1.3 | DateAndTime | accessible-for-notify | The date and time of the performance monitoring interval for which a performance monitoring threshold crossing alert is generated. |
| PMM tcaMontype | 1.3.6.1.4.1.18070.2.2.2.1.1.4 | PMMontype | accessible-for-notify | Identify the performance monitoring monitored type for which a threshold crossing alert is generated. |
| U32 tcaValue | 1.3.6.1.4.1.18070.2.2.2.1.1.5 | Unsigned32 | accessible-for-notify | The measured value of the monitored type for which a performance monitoring threshold crossing alert is generated. |
| U32 tcaThreshold | 1.3.6.1.4.1.18070.2.2.2.1.1.6 | Unsigned32 | accessible-for-notify | The threshold for the monitored type that was exceeded resulting in the generation of a performance monnitoring threshold crossing alert. |
| STR evtDescription | 1.3.6.1.4.1.18070.2.2.2.1.1.7 | DisplayString | accessible-for-notify | A textual decription of the event. |
| NOT evtObjectType | 1.3.6.1.4.1.18070.2.2.2.1.1.8 | NotifObjectType | accessible-for-notify | Identifies the type of managed object against which the event notification is raised. |
| NOT evtCodeType | 1.3.6.1.4.1.18070.2.2.2.1.1.9 | NotifCodeType | accessible-for-notify | This object value uniquely identifies the type of event that has been generated. |
| neEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.2 | |||
| shelfInvEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.3 | |||
| NTF shelfInvPluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.3.0.1 | A shelf has been detected through the shelf interconnect. | ||
| NTF shelfInvUnpluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.3.0.2 | A previously detected shelf is no longer detected through the shelf interconnect. | ||
| slotInvEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.4 | |||
| NTF slotInvPluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.4.0.1 | A circuit pack has been inserted into the identified slot. | ||
| NTF slotInvUnpluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.4.0.2 | A circuit pack has been removed from the identified slot. | ||
| NTF slotInvUpgradeStageResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.4.0.3 | The software upgrade process on the circuit pack in the identified slot has completed a stage. | ||
| shelfEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.5 | |||
| NTF shelfStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.5.0.1 | Notification of a change in the shelf's operational status or operational status qualifier. | ||
| cpEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.6 | |||
| NTF cpStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.1 | Notification of a change in the circuit pack's operational status or operational status qualifier. | ||
| NTF cpCheckUpgradeResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.2 | Indicates the result of the check upgrade step of the system-wide software upgrade process. | ||
| NTF cpUpgradeTransferResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.3 | Indicates the result of the software download step of the system-wide software upgrade process. | ||
| NTF cpUpgradeStageResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.4 | The software upgrade process on the active circuit pack in the identified slot has completed a stage. | ||
| NTF cpDbBackupResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.5 | Indicates the result of an NE database backup operation. | ||
| NTF cpDbRestoreTransferResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.6 | Indicates the result of the database download step of the NE database restore process. | ||
| NTF cpDbInvokeResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.7 | Indicates the result of the invoke step of the NE database restore process. | ||
| NTF cpDbApplyResultEvt | 1.3.6.1.4.1.18070.2.2.2.1.6.0.8 | Indicates the result of the accept step of the NE database restore process. | ||
| oaEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.7 | |||
| NTF oaStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.7.0.1 | Notification of a change in the optical amplifier's operational status or operational status qualifier. | ||
| dataCommsEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.8 | |||
| NTF oscStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.8.0.1 | Notification of a change in the optical supervisory channels's operational status or operational status qualifier. | ||
| NTF netMgmtStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.8.0.2 | Notification of a change in the network management interface's operational status or operational status qualifier. | ||
| pluggableInvEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.9 | |||
| NTF pluggableInvPluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.9.0.1 | A pluggable transceiver has been inserted into the identified port. | ||
| NTF pluggableInvUnpluginEvt | 1.3.6.1.4.1.18070.2.2.2.1.9.0.2 | A pluggable transceiver has been removed from the identified port. | ||
| xcvrEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.10 | |||
| NTF xcvrStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.10.0.1 | Notification of a change in the transceiver's operational status or operational status qualifier. | ||
| NTF xcvrProtSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.10.0.2 | A protection switch has occured on the optical transceiver facility. | ||
| NTF xcvrTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.10.0.3 | This trap provides a threshold crossing alert for a performance monitoring statistic on an optical transceiver port. | ||
| adminEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.11 | |||
| amdEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.12 | |||
| NTF amdStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.12.0.1 | Notification of a change in the operational status or operational status qualifier of an active multiplexer-demultiplexer port. | ||
| ocnEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.13 | |||
| NTF ocnStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.13.0.1 | Notification of a change in the operational status or operational status qualifier of a SONET OC-N facility port. | ||
| NTF ocnTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.13.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on a SONET OC-N facility. | ||
| NTF ocnProtSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.13.0.3 | A protection switch has occured on the identified OC-N facility. | ||
| stsnEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.14 | |||
| NTF stsnProtSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.14.0.2 | A protection switch has occured on the identified STS-N channel. | ||
| NTF stsnTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.14.0.3 | This trap provides a threshold crossing alert for a performance monitoring statistic on a SONET STS-N facility. | ||
| stmnEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.15 | |||
| NTF stmnStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.15.0.1 | Notification of a change in the operational status or operational status qualifier of a SDH STM-N facility port. | ||
| NTF stmnTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.15.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on a SDH STM-N facility. | ||
| NTF stmnProtSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.15.0.3 | A protection switch has occured on the identified STM-N facility. | ||
| vcnEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.16 | |||
| NTF vcnProtSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.16.0.2 | A protection switch has occured on the identified VC-N channel. | ||
| NTF vcnTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.16.0.3 | This trap provides a threshold crossing alert for a performance monitoring statistic on a SDH VC-N facility. | ||
| geEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.17 | |||
| NTF geStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.17.0.1 | Notification of a change in the operational status or operational status qualifier of a Gigabit Ethernet facility port. | ||
| NTF geTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.17.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on a Gigabit Ethernet facility. | ||
| fcEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.18 | |||
| NTF fcStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.18.0.1 | Notification of a change in the operational status or operational status qualifier of a Fiber Channel facility port. | ||
| NTF fcTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.18.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on a Fiber Channel facility. | ||
| ethPortEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.21 | |||
| NTF ethL1IFStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.21.0.1 | Notification of a change in the operational status or operational status qualifier of a L1 Ethernet facility port. | ||
| NTF ethL1IFTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.21.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on an Ethernet Layer 1 interface facility. | ||
| pvxL2EvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.22 | |||
| NTF pvxL2IFTcaEvt | 1.3.6.1.4.1.18070.2.2.2.1.22.0.2 | This trap provides a threshold crossing alert for a performance monitoring statistic on a PVX Pack Ethernet Layer 2 interface facility. | ||
| mstpEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.23 | |||
| briEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.24 | |||
| NTF briStatusChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.24.0.1 | Notification of a change in the operational status or operational status qualifier of a BRI facility port. | ||
| cpSynchronizationEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.25 | |||
| NTF cpSynchronizationSwitchEvt | 1.3.6.1.4.1.18070.2.2.2.1.25.0.1 | A synchronization timing reference switch has occurred on the identified circuit pack. | ||
| pvxESrvcBWPrflEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.26 | |||
| pvxESrvcEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.27 | |||
| pvxERPSSrvcNNIEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.28 | |||
| pvxERPSSrvcEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.29 | |||
| pvxSlaMsmtEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.30 | |||
| ntpcEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.31 | |||
| NTF ntpTimeAndDateUpdateEvt | 1.3.6.1.4.1.18070.2.2.2.1.31.0.1 | This event occurs when the NTP client updates the system date and time based on a selected reference clocks source. | ||
| NTF ntpTimingRefUpdateEvt | 1.3.6.1.4.1.18070.2.2.2.1.31.0.2 | This event occurs when the NTP client has selected a reference clock source from a list provided. This is the NTP association list. | ||
| pvxSUniEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.32 | |||
| olEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.33 | |||
| pvxLldpEvtNotifications | 1.3.6.1.4.1.18070.2.2.2.1.34 | |||
| NTF pvxLldpRemTablesChangeEvt | 1.3.6.1.4.1.18070.2.2.2.1.34.0.1 | A pvxLldpRemTablesChangeEvt notification is sent when the value of pvxLldpStatsRemTablesLastChangeTime changes. It can be utilized by an NMS to trigger LLDP remote systems table maintenance polls. Note that transmission of lldpRemTablesChange notifications are throttled by the agent. The agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. By default the throttling period is set to 10 seconds. | ||
| conditionNotifications | 1.3.6.1.4.1.18070.2.2.2.2 | |||
| neCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.1 | |||
| shelfInvCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.2 | |||
| NTF shelfInvMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.1 | An expansion shelf is missing. To clear this condition, attach an appropriate expansion shelf to the MSCP in the main shelf of the system. | ||
| NTF shelfInvMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.2 | A previously active shelf missing condition has cleared. | ||
| NTF shelfInvUnknownCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.3 | A shelf is unknown to the system. This condition occurs because the shelf is unknown to the system (for example, the the FRU data cannot be read on the expansion shelf interface (ESI) circuit pack in the expansion shelf). To clear this condition, connect an appropriate shelf to its associated MSCP. | ||
| NTF shelfInvUnknownClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.4 | A previously active shelf unknown condition has cleared. | ||
| NTF shelfInvCommCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.5 | This condition indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. | ||
| NTF shelfInvCommClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.6 | A previously active shelf communications condition has cleared. | ||
| NTF shelfInvPwrFeedAFailCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.7 | There is a power feed A failure. The system can continue to function on power feed B. Plan to diagnose and correct the problem as soon as possible. | ||
| NTF shelfInvPwrFeedAFailClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.8 | A previously active Power feed A condition has cleared. | ||
| NTF shelfInvPwrFeedBFailCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.9 | There is a power feed B failure. The system can continue to function on power feed A. Plan to diagnose and correct the problem as soon as possible. | ||
| NTF shelfInvPwrFeedBFailClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.10 | A previously active Power feed B condition has cleared. | ||
| NTF shelfInvPwrBrownoutCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.11 | There is a system power brownout. As voltage levels decrease, the amplifiers fail, followed by the MSCP, and then the cooling unit fails. | ||
| NTF shelfInvPwrBrownoutClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.12 | A previously active power brownout condition on the shelf has cleared. | ||
| NTF shelfInvSysCommCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.13 | This condition indicates that backplane communication between the multiport system control processor (MSCP) and the affected circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active. | ||
| NTF shelfInvSysCommClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.14 | A previously active shelf missing condition has cleared. | ||
| NTF shelfInvExpansionShelfIdMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.15 | Indicates that the identifying information of the discovered expansion shelf does not match that of the expected shelf. | ||
| NTF shelfInvExpansionShelfIdMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.16 | A previously active expansion shelf identifier mismatch condition has cleared. | ||
| NTF shelfInvExpansionShelfCommLOSCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.17 | This alarm indicates that a connected expansion shelf has a loss of signal between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. The most likely causes are a fiber cut or a fault with the Molex connector and cable assembly. | ||
| NTF shelfInvExpansionShelfCommLOSClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.18 | A previously active expansion shelf communications LOS condition has cleared. | ||
| NTF shelfInvExpansionShelfCommLinkDownCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.19 | This alarm indicates that a connected expansion shelf has a communications failure between the multiport system control processor (MSCP) and the expansion shelf interface (ESI) circuit packs. | ||
| NTF shelfInvExpansionShelfCommLinkDownClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.20 | A previously active expansion shelf communications link down condition has cleared. | ||
| NTF shelfInvExpansionShelfCommDeviceUnsupportedCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.21 | This alarm indicates that an unknown device is connected to the expansion shelf port of the multiport system control processor (MSCP) on the main shelf. | ||
| NTF shelfInvExpansionShelfCommDeviceUnsupportedClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.22 | A previously active expansion shelf communications device unsupported condition has cleared. | ||
| NTF shelfInvTempMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.2.0.23 | Indicates that the temperature on the identified shelf has risen above the maximum threshold. | ||
| NTF shelfInvTempMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.2.0.24 | A previously active shelf inventory maximum temperature condition has cleared. | ||
| slotInvCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.3 | |||
| NTF slotInvMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.1 | A Circuit pack is missing. The alarm is triggered for one of the following reasons: the provisioned circuit pack is missing from its associated slot a filler circuit pack is missing from an unprovisioned single-width or doublewidth slot a single-width circuit pack is provisioned in a double-width slot To clear this alarm, insert an appropriate single-width or double-width circuit pack or filler circuit pack in the associated single-width or double-width slot. | ||
| NTF slotInvMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.2 | A previously active circuit pack or replaceable unit missing condition has cleared. | ||
| NTF slotInvUnknownCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.3 | Circuit pack type is unknown to the system. This condition occurs for the following two reasons: the circuit pack in the associated slot is unknown to the system (for example, the circuit pack is not supported by the software release running on the system) two single-width circuit packs are in a double-width slot To clear this condition, insert an appropriate circuit pack in the associated slot. | ||
| NTF slotInvUnknownClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.4 | A previously active circuit pack or replaceable unit unknown condition has cleared. | ||
| NTF slotInvCommCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.5 | This alarm indicates that backplane communication between the multiport system control processor (MSCP) and the circuit pack is interrupted. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, are affected while this alarm is active. If an amplifier or wavelength conversion circuit pack has been provisioned already, it continues to operate normally. | ||
| NTF slotInvCommClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.6 | A previously active circuit pack communications condition has cleared. | ||
| NTF slotInvFailCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.7 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvFailClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.8 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvUpgradeInProgressCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.9 | A software upgrade process has begun on the circuit pack in the identified slot. | ||
| NTF slotInvUpgradeInProgressClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.10 | There is an auto upgrade in progress. This alarm is typically seen when inserting a circuit pack other than a multiport system control processor (MSCP). | ||
| NTF slotInvUpgradeFailureCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.11 | There is a circuit pack upgrade failure. | ||
| NTF slotInvUpgradeFailureClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.12 | A previously active circuit pack software upgrade failure condition has cleared. | ||
| NTF slotInvVersionMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.13 | The circuit pack in the indicated slot is running a software version which is inconsistent with the committed software version of the system. | ||
| NTF slotInvVersionMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.14 | A previously active circuit pack software version mismatch condition has cleared. | ||
| NTF slotInvCoolingUnitFailCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.15 | A cooling unit failure has occurred. One or more fans have failed in the cooling unit. | ||
| NTF slotInvCoolingUnitFailClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.16 | A previously active shelf cooling unit failure condition has cleared. | ||
| NTF slotInvDspCommCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.17 | This alarm indicates that communication has failed either between the DSP and the processor handling backplane communications on an optical amplifier circuit pack, or between the variable optical equalizer (VOE) and the processor handling backplane communications on an active mux/demux circuit pack Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active. | ||
| NTF slotInvDspCommClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.18 | A previously active DSP control communications condition has been cleared. | ||
| NTF slotInvUnsupportedPackCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.19 | A replaceable unit inventory item is unsupported. In this case, a multiport system control processor (MSCP) circuit pack is plugged into any slot of the expansion shelf. However, MSCPs are only supported in slot five of the main shelf. | ||
| NTF slotInvUnsupportedPackClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.20 | A previously active unsupported pack condition has cleared. | ||
| NTF slotInvCoolingUnitMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.21 | The shelf is plugged in with a wring cooling unit. | ||
| NTF slotInvCoolingUnitMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.22 | A previously active cooling unit mismatch condition has cleared. | ||
| NTF slotInvPwrFeedAFuseFailCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.23 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvPwrFeedAFuseFailClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.24 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvPwrFeedBFuseFailCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.25 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvPwrFeedBFuseFailClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.26 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvPowerFailCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.27 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvPowerFailClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.28 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvHiTempAutoShutdownCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.29 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvHiTempAutoShutdownClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.30 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvHTThreshExceededCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.31 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvHTThreshExceededClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.32 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvHTSThreshExceededCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.33 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvHTSThreshExceededClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.34 | A previously active circuit pack fail condition has cleared. | ||
| NTF slotInvHTASUnsupportedCond | 1.3.6.1.4.1.18070.2.2.2.2.3.0.35 | There is a circuit pack failure. The alarm is critical when a circuit pack is provisioned and that it has fails in its associated slot. | ||
| NTF slotInvHTASUnsupportedClear | 1.3.6.1.4.1.18070.2.2.2.2.3.0.36 | A previously active circuit pack fail condition has cleared. | ||
| shelfCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.4 | |||
| NTF shelfMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.4.0.1 | The type of the physically detected shelf does not match the provisioned shelf type. | ||
| NTF shelfMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.4.0.2 | A previously active shelf type mismatch condition has cleared. | ||
| NTF shelfMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.4.0.3 | An expansion shelf is missing. To clear this alarm, attach an appropriate expansion shelf to the MSCP in the main shelf of the system. | ||
| NTF shelfMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.4.0.4 | A previously active expansion shelf missing condition has cleared. | ||
| NTF shelfConfigurationMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.4.0.5 | The configuration type of the physically detected expansion shelf does not match the provisioned expansion shelf configuration type. | ||
| NTF shelfConfigurationMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.4.0.6 | A previously active expansion shelf configuration mismatch condition has cleared. | ||
| cpCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.5 | |||
| NTF cpMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.1 | There is a circuit pack mismatch. There is a mismatch between the equipment provisioned for the slot and the physical circuit pack that is inserted in the slot. | ||
| NTF cpMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.2 | A previously active circuit pack type mismatch condition has cleared. | ||
| NTF cpConnectorMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.3 | A connector mismatch alarm occurs on a circuit pack that is provisioned with a connector type that is different to the one actually inserted. | ||
| NTF cpConnectorMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.4 | A previously active optical fiber connector type mismatch condition has cleared. | ||
| NTF cpInvalidProvCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.5 | The type of circuit pack that is provisioned in a slot that is invalid for the shelf slot configuration. | ||
| NTF cpInvalidProvClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.6 | A previously active invalid circuit pack provisioning condition has cleared. | ||
| NTF cpSoftwareBankAFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.7 | There is a hardware failure in software bank A storage device. During this alarm, software backups, upgrades and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit. | ||
| NTF cpSoftwareBankAFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.8 | A previously active software Bank A failure condition has cleared. | ||
| NTF cpSoftwareBankBFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.9 | There is a hardware failure in software bank B storage device. During this alarm, software backups, upgrades, and restores cannot occur. When the MSCP is rebooting, the LEDs on the MSI and the MSCP are lit. | ||
| NTF cpSoftwareBankBFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.10 | A previously active software Bank B failure condition has cleared. | ||
| NTF cpUpgradeInProgressCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.11 | Indicates that a system-wide software upgrade process is in progress on the NE. | ||
| NTF cpUpgradeInProgressClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.12 | A previously active system-wide upgrade in progress condition has cleared. | ||
| NTF cpUpgradeFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.15 | Indicates that the system-wide upgrade procedure has failed to complete successfully. | ||
| NTF cpUpgradeFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.16 | A previously active circuit pack upgrade failure condition has cleared. | ||
| NTF cpDbRestoreInProgressCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.17 | There is a database restore in progress on the system. | ||
| NTF cpDbRestoreInProgressClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.18 | A previously active NE database restore condition has cleared. | ||
| NTF cpDbRecoveryFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.19 | There is a database recovery failure. If a new MSCP circuit pack fails to acquire the database from the system, a database recovery failure alarm can be triggered after replacing the MSCP. | ||
| NTF cpDbRecoveryFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.20 | A previously active NE database recovery failure condition has cleared. | ||
| NTF cpFanFeedFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.21 | A cooling unit feed failure has occurred on a BTI 7030 shelf. There are two cooling unit power feeds from the SCP to the cooling unit. If one power feeds fails, a minor alarm is raised. If both power feed fails, a major alarm is raised. | ||
| NTF cpFanFeedFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.22 | A previously active fan power feed failure condition has cleared. | ||
| NTF cpStorageCardFailCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.23 | Indicates that the database storage card has failed. | ||
| NTF cpStorageCardFailClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.24 | A previously active database storage card failure condition has cleared. | ||
| NTF cpDbDeletionInProgressCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.25 | There is a database deletion in progress on the system. | ||
| NTF cpDbDeletionInProgressClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.26 | A previously active NE database deletion condition has cleared. | ||
| NTF cpDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.5.0.27 | Indicates that a failure or degradation has been detected in one or more physical components on the identified circuit pack, which may lead to a failure of the pack to provide service normally. | ||
| NTF cpDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.5.0.28 | A previously active Circuit Pack Degrade condition has cleared. | ||
| oaCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.6 | |||
| NTF oaCaseTempCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.1 | A case temperature high threshold is exceeded. A warning is raised to indicate that the amplifier is nearing its shutdown threshold. The circuit pack in the associated slot has exceeded its case temperature high threshold. If the case temperature continues to rise to its shutdown threshold, the circuit pack automatically shuts down. | ||
| NTF oaCaseTempClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.2 | A previously active optical amplifier case temperature condition has cleared. | ||
| NTF oaCaseTempShutdownCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.3 | A case temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. The pump lasers are turned off and there is no amplification. | ||
| NTF oaCaseTempShutdownClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.4 | A previously active optical amplifier case temperature shutdown condition has cleared. | ||
| NTF oaLaserMinTempShutdownCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.5 | A pump laser temperature low threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. | ||
| NTF oaLaserMinTempShutdownClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.6 | A previously active optical amplifier minimum temperature shutdown condition has cleared. | ||
| NTF oaLaserMaxTempShutdownCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.7 | A pump laser temperature high threshold shutdown has occurred. The optical amplifier is shutdown and taken out-of-service by the system. | ||
| NTF oaLaserMaxTempShutdownClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.8 | A previously active optical amplifier maximum temperature shutdown condition has cleared. | ||
| NTF oaOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.9 | The optical power received (OPR) low threshold is exceeded. The input signal to an optical amplifier has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the circuit pack will degrade in performance. | ||
| NTF oaOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.10 | A previously active optical amplifier minimum power received condition has cleared. | ||
| NTF oaOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.11 | The optical power received (OPR) high threshold is crossed. The input signal to an optical amplifier has reached the optical power received high threshold. | ||
| NTF oaOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.12 | A previously active optical amplifier maximum power received condition has cleared. | ||
| NTF oaSSIOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.13 | A second stage input optical power received (OPR) high threshold crossing has occurred. | ||
| NTF oaSSIOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.14 | A previously active optical amplifier second stage input maximum power received condition has cleared. | ||
| NTF oaBackReflectionSafetyCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.17 | The Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the optical power received optical back reflection high threshold safety override (OPR-OBR-HTSO) command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears. | ||
| NTF oaBackReflectionSafetyClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.18 | A previously active optical amplifier back reflection safety condition has cleared. | ||
| NTF oaOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.19 | The optical power transmitted (OPT) low threshold is crossed. | ||
| NTF oaOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.20 | A previously active optical amplifier minimum transmitted power condition has cleared. | ||
| NTF oaOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.21 | The optical power transmitted (OPT) high threshold has been exceeded on the amplifier. | ||
| NTF oaOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.22 | A previously active optical amplifier maximum transmitted power condition has cleared. | ||
| NTF oaMSInsertionLossCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.23 | A mid-stage insertion loss high threshold is exceeded for a mid-stage amplifier. | ||
| NTF oaMSInsertionLossClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.24 | A previously active optical amplifier midstage insertion loss condition has cleared. | ||
| NTF oaAmplifierConditioningCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.25 | There is an amplifier conditioning problem. When an amplifier is initially plugged in, thermo-electric coolers (TEC) work to control the pump laser temperature to between 16 degrees and 34 degrees Celsius. Until the pump laser temperature is within range, the amplifier conditioning problem is present. If the amplifier conditioning problem persists for more than 30 minutes, the condition is cleared and either a laser temperature low threshold or a laser temperature high threshold alarm is raised. | ||
| NTF oaAmplifierConditioningClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.26 | A previously active optical amplifier conditioning condition has cleared. | ||
| NTF oaDspCommCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.27 | This alarm indicates that communication has failed between the DSP and the processor handling backplane communications on an optical amplifier circuit pack. Normal OAM&P operations to the circuit pack, like provisioning and performance monitoring, is affected when this alarm is active. | ||
| NTF oaDspCommClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.28 | A previously active optical amplifier DSP communications condition has cleared. | ||
| NTF oaBackReflectionSafetyOverrideCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.41 | The Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the high threshold safety override command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears. | ||
| NTF oaBackReflectionSafetyOverrideClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.42 | A previously active back reflection safety override condition has been cleared. | ||
| NTF oaBackReflectionHighThresholdCond | 1.3.6.1.4.1.18070.2.2.2.2.6.0.43 | The Optical Amplifier Back Reflection High Threshold alarm indicates that the measured optical back reflection power has exceeded the high threshold. This serves as a warning that optical back reflection is operating at an elevated level, and that continued increases in the optical back reflection level may result in an automatic laser safety shutdown. | ||
| NTF oaBackReflectionHighThresholdClear | 1.3.6.1.4.1.18070.2.2.2.2.6.0.44 | A previously active back reflection high threshold condition has been cleared. | ||
| dataCommsCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.7 | |||
| NTF oscLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.7.0.1 | This condition indicates that an SFP transceiver has experienced an input power drop that is below the manufacturer s preset threshold. | ||
| NTF oscLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.7.0.2 | A previously active optical supervisory channel loss of signal condition has cleared. | ||
| NTF oscSfpMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.7.0.3 | An SFP transceiver is missing from its associated port in an MSCP circuit pack. To clear this alarm, insert an appropriate transceiver in the associated port of the MSCP circuit pack. | ||
| NTF oscSfpMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.7.0.4 | A previously active optical supervisory channel SFP missing condition has cleared. | ||
| pluggableInvCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.8 | |||
| NTF pluggableInvUnknownCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.1 | The SFP or XFP transceiver type is unknown to the system. This alarm occurs because the transceiver is not supported by the current software. To clear this alarm, insert a readable SFP or XFP transceiver in the associated port of the circuit pack. | ||
| NTF pluggableInvUnknownClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.2 | A previously active Pluggable Inventory Unknown condition has cleared. | ||
| NTF pluggableInvCommCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.3 | This alarm indicates that communication between a circuit pack and an inserted small form factor pluggable (SFP) transceiver is not reliable. | ||
| NTF pluggableInvCommClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.4 | A previously active Pluggable Inventory communications condition has cleared. | ||
| NTF pluggableInvFailCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.5 | There is an SFP or XFP transceiver failure. | ||
| NTF pluggableInvFailClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.6 | A previously active Pluggable Inventory fail condition has cleared. | ||
| NTF pluggableInvMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.7 | There is an SFP mismatch condition active. There is a mismatch between the SFP transceiver provisioned for a port of a circuit pack and the physical SFP transceiver that is inserted in the port. | ||
| NTF pluggableInvMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.8 | A previously active Pluggable Inventory mismatch condition has cleared. | ||
| NTF pluggableInvMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.9 | There is an SFP or XFP missing from the indicated port. | ||
| NTF pluggableInvMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.10 | A previously active Pluggable Inventory missing condition has cleared. | ||
| NTF pluggableInvUnsupportedCond | 1.3.6.1.4.1.18070.2.2.2.2.8.0.11 | The electrical SFP transceiver type is NOT supported in the given port. This alarm occurs when an electrical SFP is plugged into a port that does not support GE. To clear this alarm, remove the electrical SFP. | ||
| NTF pluggableInvUnsupportedClear | 1.3.6.1.4.1.18070.2.2.2.2.8.0.12 | A previously active Pluggable unsupported condition has cleared. | ||
| xcvrCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.9 | |||
| NTF xcvrMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.1 | An SFP or XFP transceiver is missing from its associated port in a circuit pack. | ||
| NTF xcvrMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.2 | A previously active transceiver port missing condition has cleared. | ||
| NTF xcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for a port of a circuit pack and the physical SFP or XFP transceiver that is inserted in the port. The provisioned SFP or XFP transceiver must match the transceiver in the port. | ||
| NTF xcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.4 | A previously active transceiver port type mismatch condition has cleared. | ||
| NTF xcvrRFICond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.5 | Remote Fault Indication: The source port to which the specified destination transceiver port is cross-connected has a service-affecting fault active against it. | ||
| NTF xcvrRFIClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.6 | A previously active transceiver RFI condition has cleared. | ||
| NTF xcvrLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.7 | This alarm indicates that an SFP transceiver has experienced an input power drop that is below the preset minimum threshold. | ||
| NTF xcvrLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.8 | A previously active transceiver port Loss Of Signal condition has cleared. | ||
| NTF xcvrLossOfLockCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.9 | This alarm indicates that a transceiver port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded. | ||
| NTF xcvrLossOfLockClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.10 | A previously active transceiver port Loss Of Lock condition has cleared. | ||
| NTF xcvrOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.11 | The optical power received (OPR) low threshold is not met. The input signal to a transceiver has reached the optical power received low threshold. If the input signal drops to below the input sensitivity level, the transceiver degrades in performance. | ||
| NTF xcvrOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.12 | A previously active transceiver port minimum power received condition has cleared. | ||
| NTF xcvrOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.13 | The optical power received (OPR) high threshold is exceeded. The input signal to a transceiver has reached the optical power received high threshold. | ||
| NTF xcvrOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.14 | A previously active transceiver port maximum power received condition has cleared. | ||
| NTF xcvrOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.15 | The optical power transmitted (OPT) is below the low threshold for the transceiver. | ||
| NTF xcvrOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.16 | A previously active transceiver port minimum power transmitted condition has cleared. | ||
| NTF xcvrOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.17 | The optical power transmitted (OPT) high threshold for a transceiver is exceeded. | ||
| NTF xcvrOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.18 | A previously active transceiver port maximum power transmitted condition has cleared. | ||
| NTF xcvrLossOfFrameCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.19 | A transceiver reports a SONET or SDH loss of frame for a transceiver that is provisioned to receive a SONET or SDH protocol. | ||
| NTF xcvrLossOfFrameClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.20 | A previously active loss of frame condition has cleared. | ||
| NTF xcvrLossOfSyncCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.21 | Indicates that a loss of synchronization condition has been detected by the transceiver port on the incoming gigabit ethernet or 10GELAN protocol. | ||
| NTF xcvrLossOfSyncClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.22 | A previously active loss of synchronization condition has cleared. | ||
| NTF xcvrLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.27 | Indicates that the transceiver has been provisioned to enter loopback mode. | ||
| NTF xcvrLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.28 | A previously active loopback condition on the transceiver has been cleared. | ||
| NTF xcvrForcedSwitchToProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.29 | The active transceiver of a protected transceiver pair has been forced to switch to the Protection transceiver. | ||
| NTF xcvrForcedSwitchToProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.30 | A previously active Forced Switch To Protection condition has cleared. | ||
| NTF xcvrForcedSwitchToWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.31 | The active transceiver of a protected transceiver pair has been forced to switch to the Working transceiver. | ||
| NTF xcvrForcedSwitchToWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.32 | A previously active Forced Switch To Working condition has cleared. | ||
| NTF xcvrLockoutProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.33 | The Protection transceiver of a protected transceiver pair has been locked out. | ||
| NTF xcvrLockoutProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.34 | A previously active Lockout Protection condition has cleared. | ||
| NTF xcvrLockoutWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.35 | The Working transceiver of a protected transceiver pair has been locked out. | ||
| NTF xcvrLockoutWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.36 | A previously active Lockout Working condition has cleared. | ||
| NTF xcvrTempMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.37 | Indicates that the temperature of the physical transceiver has risen above the maximum threshold. | ||
| NTF xcvrTempMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.38 | A previously active Temperature Exceeded Maximum condition has cleared. | ||
| NTF xcvrWavelengthNotAchievableCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.39 | Indicates that the transceiver is not currently able to tune to the set wavelength. | ||
| NTF xcvrWavelengthNotAchievableClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.40 | A previously active Wavelength Not Achievable condition has cleared. | ||
| NTF xcvrAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.41 | An Alarm Indication Signal indication is active on the transceiver port. | ||
| NTF xcvrAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.42 | A previously active Alarm Indication Signal condition has cleared. | ||
| NTF xcvrTraceMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.43 | This condition indicates that the received trace label on the transciever port does not match the expected trace label. | ||
| NTF xcvrTraceMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.44 | A previously active Trace Mismatch condition has cleared. | ||
| NTF xcvrRemoteFaultCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.45 | A remote fault indication is active on the traceiver port. | ||
| NTF xcvrRemoteFaultClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.46 | A previously raised remote fault indication has cleared. | ||
| NTF xcvrSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.47 | The Signal Degrade BER threshold has been crossed on the transiever port. | ||
| NTF xcvrSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.48 | A previously active Signal Degrade condition has cleared. | ||
| NTF xcvrOTNPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.49 | An OTN payload mismatch is active on the transceiver port facility. | ||
| NTF xcvrOTNPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.50 | A previously active OTN payload mismatch condition on the transceiver port facility has cleared. | ||
| NTF xcvrLFCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.51 | Local Failure: Raised when a port detects and incoming local failure indication is received. | ||
| NTF xcvrLFClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.52 | A previously active transceiver LF condition has cleared. | ||
| NTF xcvrOpenConnectionIndicatorCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.53 | An Open Connection Indicator is active on the transceiver port. | ||
| NTF xcvrOpenConnectionIndicatorClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.54 | A previously active Open Connection Indicator condition has cleared. | ||
| NTF xcvrReceivedLockoutCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.55 | A Received Lockout indication is active on the transceiver port. | ||
| NTF xcvrReceivedLockoutClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.56 | A previously active Received Lockout condition has cleared. | ||
| NTF xcvrBackwardDefectIndicatorCond | 1.3.6.1.4.1.18070.2.2.2.2.9.0.57 | A Backward Defect Indicator is active on the transceiver port. | ||
| NTF xcvrBackwardDefectIndicatorClear | 1.3.6.1.4.1.18070.2.2.2.2.9.0.58 | A previously active Backward Defect Indicator condition has cleared. | ||
| adminCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.10 | |||
| NTF tl1UserLockoutCond | 1.3.6.1.4.1.18070.2.2.2.2.10.0.1 | A user is locked out of the system. After three incorrect attempts to login, a user is blocked from attempting to login again for 60 seconds. | ||
| NTF tl1UserLockoutClear | 1.3.6.1.4.1.18070.2.2.2.2.10.0.2 | A previously active TL1 User Lockout condition has cleared. | ||
| NTF tl1IpLockoutCond | 1.3.6.1.4.1.18070.2.2.2.2.10.0.3 | After three incorrect attempts to login from the same IP address, the IP address from which the three attempts are made is blocked for 60 seconds. When this condition is present in the actCondTable, the actCondTableEntryIdx will be set to the networkElement OID and the actCondInstanceIdx will be set to 0. | ||
| NTF tl1IpLockoutClear | 1.3.6.1.4.1.18070.2.2.2.2.10.0.4 | A previously active TL1 IP lockout condition has cleared. | ||
| amdCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.11 | |||
| NTF amdLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.11.0.1 | This condition indicates that an active mux/demux that has experienced an input power drop that is below the preset threshold. This can be against either a channel or the composite line port. | ||
| NTF amdLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.11.0.2 | A previously raised active multiplexer-demultiplexer loss of signal condition has cleared. | ||
| NTF amdOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.11.0.3 | Indicates that the input power for the active multiplexer-demultiplexer facility has fallen below the minimum threshold. | ||
| NTF amdOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.11.0.4 | A previously raised active multiplexer-demultiplexer minimum power received condition has cleared. | ||
| NTF amdOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.11.0.5 | Indicates that the input power for the active multiplexer-demultiplexer facility has risen above the maximum threshold. | ||
| NTF amdOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.11.0.6 | A previously raised active multiplexer-demultiplexer maximum power received condition has cleared. | ||
| NTF amdTPLNACond | 1.3.6.1.4.1.18070.2.2.2.2.11.0.7 | A channel target power level not achieved (TPLNA) condition is triggered when the output power for a channel of a 32-Channel DWDM Active Mux/Demux (D32AMD) module is above or below the target power transmitted level for that channel. | ||
| NTF amdTPLNAClear | 1.3.6.1.4.1.18070.2.2.2.2.11.0.8 | A previously raised active target power level not achieved condition has been cleared. | ||
| NTF amdTALNACond | 1.3.6.1.4.1.18070.2.2.2.2.11.0.9 | The target attenuation level not achieved (TALNA) condition is triggered when the attenuation for a 32-Channel DWDM Active Mux/Demux (D32AMD) is outside the preset attenuation levels for a composite line. | ||
| NTF amdTALNAClear | 1.3.6.1.4.1.18070.2.2.2.2.11.0.10 | A previously raised active target attenuation level not achieved condition has been cleared. | ||
| ocnCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.12 | |||
| NTF ocnLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.1 | This notification indicates that there is no input signal detected on the OC-N port. | ||
| NTF ocnLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.2 | This notification indicates that a previously active OC-N Loss of Signal condition has been cleared. | ||
| NTF ocnXcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for the OC-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the OC-N facility. | ||
| NTF ocnXcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.4 | A previously active OC-N Mismatch condition has cleared. | ||
| NTF ocnOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.5 | Indicates that the input power for the OC-N facility has fallen below the minimum threshold. | ||
| NTF ocnOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.6 | A previously active OC-N minimum power recieved condition has cleared. | ||
| NTF ocnOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.7 | Indicates that the input power for the OC-N facility has risen above the maximum threshold. | ||
| NTF ocnOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.8 | A previously active OC-N maximum power recieved condition has cleared. | ||
| NTF ocnOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.9 | Indicates that the output power for the OC-N facility has fallen below the minimum threshold. | ||
| NTF ocnOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.10 | A previously active OC-N minimum power transmitted condition has cleared. | ||
| NTF ocnOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.11 | Indicates that the output power for the OC-N facility has risen above the maximum threshold. | ||
| NTF ocnOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.12 | A previously active OC-N maximum power transmitted condition has cleared. | ||
| NTF ocnLossOfFrameCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.13 | An OC-N Loss of Frame condition is active on the port. | ||
| NTF ocnLossOfFrameClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.14 | A previously active OC-N Loss of Frame condition has cleared. | ||
| NTF ocnSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.15 | A signal degrade condition on the OC-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold. | ||
| NTF ocnSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.16 | A previously active OC-N Signal Degrade condition has cleared. | ||
| NTF ocnAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.17 | An OC-N Line-level Alarm Indication Signal indication is active on facility. | ||
| NTF ocnAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.18 | A previously active OC-N Alarm Indication Signal condition has cleared. | ||
| NTF ocnLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.19 | Indicates that the OC-N facility has been provisioned to enter loopback mode. | ||
| NTF ocnLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.20 | A previously active loopback condition on the OC-N facility has been cleared. | ||
| NTF ocnLossOfPrimaryTimingReferenceCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.21 | Indicates that the primary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on. | ||
| NTF ocnLossOfPrimaryTimingReferenceClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.22 | A previously active OC-N Loss of Primary Timing Reference condition has cleared. | ||
| NTF ocnLossOfSecondaryTimingReferenceCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.23 | Indicates that the secondary timing reference signal for the identified OC-N facility is missing or faulty and cannot be locked on. | ||
| NTF ocnLossOfSecondaryTimingReferenceClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.24 | A previously active OC-N Loss of Secondary Timing Reference condition has cleared. | ||
| NTF ocnOTNPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.25 | An OTN payload mismatch is active on the facility. | ||
| NTF ocnOTNPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.26 | A previously active OTN payload mismatch condition has cleared. | ||
| NTF ocnForcedSwitchToProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.27 | The active line of a protected line pair has been forced to switch to the Protection line. | ||
| NTF ocnForcedSwitchToProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.28 | A previously active Forced Switch To Protection condition has cleared. | ||
| NTF ocnForcedSwitchToWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.29 | The active line of a protected line pair has been forced to switch to the Working line. | ||
| NTF ocnForcedSwitchToWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.30 | A previously active Forced Switch To Working condition has cleared. | ||
| NTF ocnLockoutProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.31 | The Protection line of a protected line pair has been locked out. | ||
| NTF ocnLockoutProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.32 | A previously active Lockout Protection condition has cleared. | ||
| NTF ocnLockoutWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.33 | The Working line of a protected line pair has been locked out. | ||
| NTF ocnLockoutWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.34 | A previously active Lockout Working condition has cleared. | ||
| NTF ocnWavelengthNotAchievableCond | 1.3.6.1.4.1.18070.2.2.2.2.12.0.35 | The tunable pluggable cannot be tuned to the provisioned wavelength. | ||
| NTF ocnWavelengthNotAchievableClear | 1.3.6.1.4.1.18070.2.2.2.2.12.0.36 | A previously active Wavelength Not Achievable condition has cleared. | ||
| stsnCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.13 | |||
| NTF stsnAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.1 | A Path-level Alarm Indication Signal indication is active on the STS-N channel. | ||
| NTF stsnAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.2 | A previously active STS-N Alarm Indication Signal condition has cleared. | ||
| NTF stsnLossOfPointerCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.3 | A Loss of Pointer condition is active on the STS-N channel. | ||
| NTF stsnLossOfPointerClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.4 | A previously raised STS-N Loss of Pointer condition has cleared. | ||
| NTF stsnUnequippedCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.5 | An Unequipped indication has been detected for the STS-N channel. | ||
| NTF stsnUnequippedClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.6 | A previously raised STS-N Unequipped condition has cleared. | ||
| NTF stsnSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.7 | A signal degrade condition on the STS-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold. | ||
| NTF stsnSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.8 | A previously raised STS-N signal degrade condition has cleared. | ||
| NTF stsnForcedSwitchToProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.9 | The active STS-N channel of a protected STS-N channel pair has been forced to switch to the Protection transceiver. | ||
| NTF stsnForcedSwitchToProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.10 | A previously raised STS-N Forced Switch To Protection condition has cleared. | ||
| NTF stsnForcedSwitchToWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.11 | The active STS-N channel of a protected STS-N channel pair has been forced to switch to the Working transceiver. | ||
| NTF stsnForcedSwitchToWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.12 | A previously raised STS-N Forced Switch To Working condition has cleared. | ||
| NTF stsnLockoutProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.13 | The Protection STS-N channel of a protected STS-N channel pair has been locked out. | ||
| NTF stsnLockoutProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.14 | A previously raised STS-N Lockout Protection condition has cleared. | ||
| NTF stsnLockoutWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.15 | The Working STS-N channel of a protected STS-N channel pair has been locked out. | ||
| NTF stsnLockoutWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.16 | A previously raised STS-N Lockout Working condition has cleared. | ||
| NTF stsnConcatMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.13.0.17 | A connection provisioning does not match has been detected for the STS-N channel. | ||
| NTF stsnConcatMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.13.0.18 | A previously raised STS-N Concat Mismatch condition has cleared. | ||
| stmnCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.14 | |||
| NTF stmnLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.1 | This notification indicates that there is no input signal detected on the STM-N port. | ||
| NTF stmnLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.2 | This notification indicates that a previously active STM-N Loss of Signal condition has been cleared. | ||
| NTF stmnXcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for the STM-N facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the STM-N facility. | ||
| NTF stmnXcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.4 | A previously active STM-N Mismatch condition has cleared. | ||
| NTF stmnOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.5 | Indicates that the input power for the STM-N facility has fallen below the minimum threshold. | ||
| NTF stmnOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.6 | A previously active STM-N minimum power recieved condition has cleared. | ||
| NTF stmnOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.7 | Indicates that the input power for the STM-N facility has risen above the maximum threshold. | ||
| NTF stmnOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.8 | A previously active STM-N maximum power recieved condition has cleared. | ||
| NTF stmnOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.9 | Indicates that the output power for the STM-N facility has fallen below the minimum threshold. | ||
| NTF stmnOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.10 | A previously active STM-N minimum power transmitted condition has cleared. | ||
| NTF stmnOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.11 | Indicates that the output power for the STM-N facility has risen above the maximum threshold. | ||
| NTF stmnOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.12 | A previously active STM-N maximum power transmitted condition has cleared. | ||
| NTF stmnLossOfFrameCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.13 | An STM-N Loss of Frame condition is active on the port. | ||
| NTF stmnLossOfFrameClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.14 | A previously active STM-N Loss of Frame condition has cleared. | ||
| NTF stmnSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.15 | A signal degrade condition on the STM-N facility is active. This indicates that the detected bit error rate exceeds the degrade threshold. | ||
| NTF stmnSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.16 | A previously active STM-N Signal Degrade condition has cleared. | ||
| NTF stmnAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.17 | An STM-N Line-level Alarm Indication Signal indication is active on facility. | ||
| NTF stmnAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.18 | A previously active STM-N Alarm Indication Signal condition has cleared. | ||
| NTF stmnLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.19 | Indicates that the STM-N facility has been provisioned to enter loopback mode. | ||
| NTF stmnLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.20 | A previously active loopback condition on the STM-N facility has been cleared. | ||
| NTF stmnLossOfPrimaryTimingReferenceCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.21 | Indicates that the primary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on. | ||
| NTF stmnLossOfPrimaryTimingReferenceClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.22 | A previously active STM-N Loss of Primary Timing Reference condition has cleared. | ||
| NTF stmnLossOfSecondaryTimingReferenceCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.23 | Indicates that the secondary timing reference signal for the identified STM-N facility is missing or faulty and cannot be locked on. | ||
| NTF stmnLossOfSecondaryTimingReferenceClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.24 | A previously active STM-N Loss of Secondary Timing Reference condition has cleared. | ||
| NTF stmnOTNPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.25 | An OTN payload mismatch is active on the facility. | ||
| NTF stmnOTNPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.26 | A previously active OTN payload mismatch condition has cleared. | ||
| NTF stmnForcedSwitchToProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.27 | The active line of a protected line pair has been forced to switch to the Protection line. | ||
| NTF stmnForcedSwitchToProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.28 | A previously active Forced Switch To Protection condition has cleared. | ||
| NTF stmnForcedSwitchToWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.29 | The active line of a protected line pair has been forced to switch to the Working line. | ||
| NTF stmnForcedSwitchToWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.30 | A previously active Forced Switch To Working condition has cleared. | ||
| NTF stmnLockoutProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.31 | The Protection line of a protected line pair has been locked out. | ||
| NTF stmnLockoutProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.32 | A previously active Lockout Protection condition has cleared. | ||
| NTF stmnLockoutWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.33 | The Working line of a protected line pair has been locked out. | ||
| NTF stmnLockoutWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.34 | A previously active Lockout Working condition has cleared. | ||
| NTF stmnWavelengthNotAchievableCond | 1.3.6.1.4.1.18070.2.2.2.2.14.0.35 | A previously active Wavelength Not Achievable condition has cleared. | ||
| NTF stmnWavelengthNotAchievableClear | 1.3.6.1.4.1.18070.2.2.2.2.14.0.36 | A previously active Lockout Working condition has cleared. | ||
| vcnCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.15 | |||
| NTF vcnAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.1 | A Path-level Alarm Indication Signal indication is active on the VC-N channel. | ||
| NTF vcnAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.2 | A previously active VC-N Alarm Indication Signal condition has cleared. | ||
| NTF vcnLossOfPointerCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.3 | A Loss of Pointer condition is active on the VC-N channel. | ||
| NTF vcnLossOfPointerClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.4 | A previously raised VC-N Loss of Pointer condition has cleared. | ||
| NTF vcnUnequippedCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.5 | An Unequipped indication has been detected for the VC-N channel. | ||
| NTF vcnUnequippedClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.6 | A previously raised VC-N Unequipped condition has cleared. | ||
| NTF vcnSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.7 | A signal degrade condition on the VC-N channel is active. This indicates that the detected bit error rate exceeds the degrade threshold. | ||
| NTF vcnSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.8 | A previously raised VC-N signal degrade condition has cleared. | ||
| NTF vcnForcedSwitchToProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.9 | The active VC-N channel of a protected VC-N channel pair has been forced to switch to the Protection transceiver. | ||
| NTF vcnForcedSwitchToProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.10 | A previously raised VC-N Forced Switch To Protection condition has cleared. | ||
| NTF vcnForcedSwitchToWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.11 | The active VC-N channel of a protected VC-N channel pair has been forced to switch to the Working transceiver. | ||
| NTF vcnForcedSwitchToWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.12 | A previously raised VC-N Forced Switch To Working condition has cleared. | ||
| NTF vcnLockoutProtectionCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.13 | The Protection VC-N channel of a protected VC-N channel pair has been locked out. | ||
| NTF vcnLockoutProtectionClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.14 | A previously raised VC-N Lockout Protection condition has cleared. | ||
| NTF vcnLockoutWorkingCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.15 | The Working VC-N channel of a protected VC-N channel pair has been locked out. | ||
| NTF vcnLockoutWorkingClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.16 | A previously raised VC-N Lockout Working condition has cleared. | ||
| NTF vcnConcatMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.15.0.17 | A connection provisioning does not match has been detected for the VC-N channel. | ||
| NTF vcnConcatMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.15.0.18 | A previously raised VC-N Concat Mismatch condition has cleared. | ||
| geCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.16 | |||
| NTF geLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.1 | This notification indicates that there is no input signal detected on the Gigabit Ethernet port. | ||
| NTF geLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.2 | This notification indicates that a previously active GE Loss of Signal condition has been cleared. | ||
| NTF geXcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for the Gigabit Ethernet facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the GE facility. | ||
| NTF geXcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.4 | A previously active GE Mistmatch condition has cleared. | ||
| NTF geOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.5 | Indicates that the input power for the Gigabit Ethernet facility has fallen below the minimum threshold. | ||
| NTF geOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.6 | A previously active GE minimum power recieved condition has cleared. | ||
| NTF geOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.7 | Indicates that the input power for the Gigabity Ethernet facility has risen above the maximum threshold. | ||
| NTF geOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.8 | A previously active GE maximum power recieved condition has cleared. | ||
| NTF geOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.9 | Indicates that the output power for the Gigabit Ethernet facility has fallen below the minimum threshold. | ||
| NTF geOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.10 | A previously active GE minimum power transmitted condition has cleared. | ||
| NTF geOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.11 | Indicates that the output power for the Gigabit Ethernet facility has risen above the maximum threshold. | ||
| NTF geOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.12 | A previously active GE maximum power transmitted condition has cleared. | ||
| NTF geLossOfSyncCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.13 | A Gigabit Ethernet Loss of Synchronization condition is active on the port. | ||
| NTF geLossOfSyncClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.14 | A previously active Gigabit Ethernet Loss of Synchronization condition has cleared. | ||
| NTF geRemotePathFailureCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.15 | A Gigabit Ethernet Remote Path Failure condition is active on the port. | ||
| NTF geRemotePathFailureClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.16 | A previously active GE Remote Path Failure condition has cleared. | ||
| NTF geLossOfMultiframeCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.17 | A Loss of Multiframe condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | ||
| NTF geLossOfMultiframeClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.18 | A previously raised GE Loss of Multiframe condition has cleared. | ||
| NTF geLossOfSequenceCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.19 | A Loss of Sequence condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | ||
| NTF geLossOfSequenceClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.20 | A previously active GE Loss of Sequence condition has cleared. | ||
| NTF geLossOfAlignmentCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.21 | A Loss of Alignment condition is active against the VCG that is mapped to the identified Gigabit Ethernet port. | ||
| NTF geLossOfAlignmentClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.22 | A previously active GE Loss of Alignment condition has cleared. | ||
| NTF geLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.23 | Indicates that the Gigabit Ethernet facility has been provisioned to enter loopback mode. | ||
| NTF geLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.24 | A previously active GE Loopback condition has cleared. | ||
| NTF geBandwidthMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.25 | A GE bandwidth mismatch condition is active on the port. | ||
| NTF geBandwidthMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.26 | A previously active GE bandwidth mismatch condition has cleared. | ||
| NTF gePayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.16.0.27 | A GE payload mismatch condition is active on the port. | ||
| NTF gePayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.16.0.28 | A previously active GE payload mismatch condition has cleared. | ||
| fcCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.17 | |||
| NTF fcLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.1 | This notification indicates that there is no input signal detected on the Fiber Channel port. | ||
| NTF fcLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.2 | This notification indicates that a previously active FC Loss of Signal condition has been cleared. | ||
| NTF fcXcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for the Fiber Channel facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the FC facility. | ||
| NTF fcXcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.4 | A previously active FC XCVR Mistmatch condition has cleared. | ||
| NTF fcOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.5 | Indicates that the input power for the Fiber Channel facility has fallen below the minimum threshold. | ||
| NTF fcOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.6 | A previously active FC minimum power recieved condition has cleared. | ||
| NTF fcOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.7 | Indicates that the input power for the Fiber Channel facility has risen above the maximum threshold. | ||
| NTF fcOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.8 | A previously active FC maximum power recieved condition has cleared. | ||
| NTF fcOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.9 | Indicates that the output power for the Fiber Channel facility has fallen below the minimum threshold. | ||
| NTF fcOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.10 | A previously active FC minimum power transmitted condition has cleared. | ||
| NTF fcOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.11 | Indicates that the output power for the Fiber Channel facility has risen above the maximum threshold. | ||
| NTF fcOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.12 | A previously active FC maximum power transmitted condition has cleared. | ||
| NTF fcLossOfSyncCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.13 | A Fiber Channel Loss of Synchronization condition is active on the port. | ||
| NTF fcLossOfSyncClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.14 | A previously active Fiber Channel Loss of Synchronization condition has cleared. | ||
| NTF fcRemotePathFailureCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.15 | A Fiber Channel Remote Path Failure condition is active on the port. | ||
| NTF fcRemotePathFailureClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.16 | A previously active FC Remote Path Failure condition has cleared. | ||
| NTF fcLossOfMultiframeCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.17 | A Loss of Multiframe condition is active against the VCG that is mapped to the identified Fiber Channel port. | ||
| NTF fcLossOfMultiframeClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.18 | A previously raised FC Loss of Multiframe condition has cleared. | ||
| NTF fcLossOfSequenceCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.19 | A Loss of Sequence condition is active against the VCG that is mapped to the identified Fiber Channel port. | ||
| NTF fcLossOfSequenceClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.20 | A previously active FC Loss of Sequence condition has cleared. | ||
| NTF fcLossOfAlignmentCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.21 | A Loss of Alignment condition is active against the VCG that is mapped to the identified Fiber Channel port. | ||
| NTF fcLossOfAlignmentClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.22 | A previously active FC Loss of Alignment condition has cleared. | ||
| NTF fcLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.23 | Indicates that the Fiber Channel facility has been provisioned to enter loopback mode. | ||
| NTF fcLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.24 | A previously active FC Loopback condition has cleared. | ||
| NTF fcBandwidthMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.25 | A Fiber Channel bandwidth mismatch condition is active on the port. | ||
| NTF fcBandwidthMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.26 | A previously active Fiber Channel bandwidth mismatch condition has cleared. | ||
| NTF fcPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.17.0.27 | A Fiber Channel payload mismatch condition is active on the port. | ||
| NTF fcPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.17.0.28 | A previously active Fiber Channel payload mismatch condition has cleared. | ||
| ethPortCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.20 | |||
| NTF olsSFPMissingCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.1 | |||
| NTF olsSFPMissingClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.2 | |||
| NTF olsSFPMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.3 | |||
| NTF olsSFPMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.4 | |||
| NTF olsInputLOSCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.5 | |||
| NTF olsInputLOSClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.6 | |||
| NTF olsOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.7 | |||
| NTF olsOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.8 | |||
| NTF olsOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.9 | |||
| NTF olsOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.10 | |||
| NTF olsOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.11 | |||
| NTF olsOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.12 | |||
| NTF olsOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.13 | |||
| NTF olsOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.14 | |||
| NTF olsTemperatureMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.15 | |||
| NTF olsTemperatureMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.16 | |||
| NTF olsLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.17 | |||
| NTF olsLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.18 | |||
| NTF olsLossOfSyncCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.19 | |||
| NTF olsLossOfSyncClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.20 | |||
| NTF olsLossOfFrameCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.21 | |||
| NTF olsLossOfFrameClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.22 | |||
| NTF olsAlarmIndicationSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.23 | |||
| NTF olsAlarmIndicationSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.24 | |||
| NTF olsBackwardDefectIndicatorCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.25 | |||
| NTF olsBackwardDefectIndicatorClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.26 | |||
| NTF olsSignalDegradeCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.27 | |||
| NTF olsSignalDegradeClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.28 | |||
| NTF olsOTNPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.29 | |||
| NTF olsOTNPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.30 | |||
| NTF olsOTUTrailTraceMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.31 | |||
| NTF olsOTUTrailTraceMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.32 | |||
| NTF olsRemoteFaultCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.33 | A remote fault indication is active on the ethernet interface. | ||
| NTF olsRemoteFaultClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.34 | A previously raised remote fault indication has cleared. | ||
| NTF olsLocalFaultCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.35 | A local fault indication is active on the ethernet interface. | ||
| NTF olsLocalFaultClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.36 | A previously raised local fault indication has cleared. | ||
| NTF olsWavelengthNotAchievableCond | 1.3.6.1.4.1.18070.2.2.2.2.20.0.37 | |||
| NTF olsWavelengthNotAchievableClear | 1.3.6.1.4.1.18070.2.2.2.2.20.0.38 | |||
| pvxL2PortCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.21 | |||
| NTF olsLinkDownCond | 1.3.6.1.4.1.18070.2.2.2.2.21.0.1 | PVX L2 port link down. | ||
| NTF olsLinkDownClear | 1.3.6.1.4.1.18070.2.2.2.2.21.0.2 | PVX L2 port link down has cleared. | ||
| mstpCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.22 | |||
| lagCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.23 | |||
| odunCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.24 | |||
| NTF odunPayloadMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.24.0.1 | A payload mismatch is active on the ODU-N facility. | ||
| NTF odunPayloadMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.24.0.2 | A previously active ODU-N facility payload mismatch condition has cleared. | ||
| NTF odunOpenConnectionIndicatorCond | 1.3.6.1.4.1.18070.2.2.2.2.24.0.3 | An OCI is active on the ODU-N facility. | ||
| NTF odunOpenConnectionIndicatorClear | 1.3.6.1.4.1.18070.2.2.2.2.24.0.4 | A previously active ODU-N OCI condition has cleared. | ||
| briCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.25 | |||
| NTF briLossOfSignalCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.1 | This notification indicates that there is no input signal detected on the BRI port. | ||
| NTF briLossOfSignalClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.2 | This notification indicates that a previously active BRI Loss of Signal condition has been cleared. | ||
| NTF briXcvrMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.3 | There is a mismatch between the SFP or XFP transceiver provisioned for the BRI facility port and the physical transceiver that is inserted in the port. The SFP or XFP transceiver in the port must match the attributes provisioned for the BRI facility. | ||
| NTF briXcvrMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.4 | A previously active BRI XCVR Mistmatch condition has cleared. | ||
| NTF briOpticalPwrReceivedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.5 | Indicates that the input power for the BRI facility has fallen below the minimum threshold. | ||
| NTF briOpticalPwrReceivedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.6 | A previously active BRI minimum power recieved condition has cleared. | ||
| NTF briOpticalPwrReceivedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.7 | Indicates that the input power for the BRI facility has risen above the maximum threshold. | ||
| NTF briOpticalPwrReceivedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.8 | A previously active BRI maximum power recieved condition has cleared. | ||
| NTF briOpticalPwrTransmittedMinCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.9 | Indicates that the output power for the BRI facility has fallen below the minimum threshold. | ||
| NTF briOpticalPwrTransmittedMinClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.10 | A previously active BRI minimum power transmitted condition has cleared. | ||
| NTF briOpticalPwrTransmittedMaxCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.11 | Indicates that the output power for the BRI facility has risen above the maximum threshold. | ||
| NTF briOpticalPwrTransmittedMaxClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.12 | A previously active BRI maximum power transmitted condition has cleared. | ||
| NTF briLossOfMultiframeCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.13 | A Loss of Multiframe condition is active against the VCG that is mapped to the identified BRI port. | ||
| NTF briLossOfMultiframeClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.14 | A previously raised BRI Loss of Multiframe condition has cleared. | ||
| NTF briLossOfSequenceCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.15 | A Loss of Sequence condition is active against the VCG that is mapped to the identified BRI port. | ||
| NTF briLossOfSequenceClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.16 | A previously active BRI Loss of Sequence condition has cleared. | ||
| NTF briLossOfAlignmentCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.17 | A Loss of Alignment condition is active against the VCG that is mapped to the identified BRI port. | ||
| NTF briLossOfAlignmentClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.18 | A previously active BRI Loss of Alignment condition has cleared. | ||
| NTF briLoopbackCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.19 | Indicates that the BRI facility has been provisioned to enter loopback mode. | ||
| NTF briLoopbackClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.20 | A previously active BRI Loopback condition has cleared. | ||
| NTF briBandwidthMismatchCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.21 | A BRI bandwidth mismatch condition is active on the port. | ||
| NTF briBandwidthMismatchClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.22 | A previously active BRI bandwidth mismatch condition has cleared. | ||
| NTF briLossOfLockCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.23 | This alarm indicates that a BRI port is unable to lock on the incoming bit stream. This is a result of either: the provisioned protocol does not match the incoming signal, or the incoming signal is excessively degraded. | ||
| NTF briLossOfLockClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.24 | A previously active BRI loss of lock condition has cleared. | ||
| NTF briTxLockingCond | 1.3.6.1.4.1.18070.2.2.2.2.25.0.25 | This alarm indicates that a BRI client port is in the process of locking on the signal in the transmit direction. | ||
| NTF briTxLockingClear | 1.3.6.1.4.1.18070.2.2.2.2.25.0.26 | A previously active BRI TX locking condition has cleared. | ||
| ntpcCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.26 | |||
| NTF ntpAssocSrvrNotReachableCond | 1.3.6.1.4.1.18070.2.2.2.2.26.0.1 | This alarm indicates that an NTP server can not be reached. This is a result of either: an invalid IP address, network problems or the server is down. | ||
| NTF ntpAssocSrvrNotReachableClear | 1.3.6.1.4.1.18070.2.2.2.2.26.0.2 | A previously active NTP server not reachable condition has cleared. | ||
| NTF ntpAssocSrvrNotRespondingCond | 1.3.6.1.4.1.18070.2.2.2.2.26.0.3 | This alarm indicates that an NTP server is reachable but is not responding to the NTP requests correctly. This can be a result of either: the server does not have the service running or there is a server is having problems. | ||
| NTF ntpAssocSrvrNotRespondingClear | 1.3.6.1.4.1.18070.2.2.2.2.26.0.4 | A previously active NTP server not responding condition has cleared. | ||
| NTF ntpAssocAuthenFailedCond | 1.3.6.1.4.1.18070.2.2.2.2.26.0.5 | This alarm indicates that NTP authentication has failed. This can be a result of either: the key is configured incorrectly on the client side or the NTP server does not accept the key. | ||
| NTF ntpAssocAuthenFailedClear | 1.3.6.1.4.1.18070.2.2.2.2.26.0.6 | A previously active NTP authentication failed condition has cleared. | ||
| envCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.27 | |||
| NTF envAttrUnsupportedCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.1 | Indicates that an environmental alarm detection is configured against a housekeeping input port which is located on equipment which does not support the configured function. | ||
| NTF envAttrUnsupportedClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.2 | A previously active environmental attribute unsupported alarm has cleared. | ||
| NTF envAirComprCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.3 | Indicates that an environmental air compressor failure alarm is raised. | ||
| NTF envAirComprClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.4 | A previously active environmental air compressor failure alarm has cleared. | ||
| NTF envAirCondCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.5 | Indicates that an environmental air conditioning failure alarm is raised. | ||
| NTF envAirCondClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.6 | A previously active environmental air conditioning failure alarm has cleared. | ||
| NTF envAirDryrCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.7 | Indicates that an environmental air dryer failure alarm is raised. | ||
| NTF envAirDryrClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.8 | A previously active environmental air dryer failure alarm has cleared. | ||
| NTF envBatDschrdCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.9 | Indicates that an environmental battery discharging alarm is raised. | ||
| NTF envBatDschrdClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.10 | A previously active environmental battery discharging alarm has cleared. | ||
| NTF envBatteryCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.11 | Indicates that an environmental battery failure alarm is raised. | ||
| NTF envBatteryClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.12 | A previously active environmental battery failure alarm has cleared. | ||
| NTF envClFanCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.13 | Indicates that an environmental cooling fan failure alarm is raised. | ||
| NTF envClFanClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.14 | A previously active environmental cooling fan failure alarm has cleared. | ||
| NTF envCpMajorCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.15 | Indicates that an environmental centralized power major alarm is raised. | ||
| NTF envCpMajorClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.16 | A previously active environmental centralized power major alarm has cleared. | ||
| NTF envCpMinorCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.17 | Indicates that an environmental centralized power minor alarm is raised. | ||
| NTF envCpMinorClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.18 | A previously active environmental centralized power minor alarm has cleared. | ||
| NTF envDoorOpenCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.19 | Indicates that an environmental door open alarm is raised. | ||
| NTF envDoorOpenClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.20 | A previously active environmental door open alarm has cleared. | ||
| NTF envEngineCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.21 | Indicates that an environmental engine failure alarm is raised. | ||
| NTF envEngineClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.22 | A previously active environmental engine failure alarm has cleared. | ||
| NTF envEngOprgCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.23 | Indicates that an environmental engine operating alarm is raised. | ||
| NTF envEngOprgClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.24 | A previously active environmental engine operating alarm has cleared. | ||
| NTF envExplGsCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.25 | Indicates that an environmental explosive gas alarm is raised. | ||
| NTF envExplGsClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.26 | A previously active environmental explosive gas alarm has cleared. | ||
| NTF envFirDetrCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.27 | Indicates that an environmental fire detector failure alarm is raised. | ||
| NTF envFirDetrClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.28 | A previously active environmental fire detector failure alarm has cleared. | ||
| NTF envFireCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.29 | Indicates that an environmental fire alarm is raised. | ||
| NTF envFireClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.30 | A previously active environmental fire alarm has cleared. | ||
| NTF envFloodCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.31 | Indicates that an environmental flood alarm is raised. | ||
| NTF envFloodClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.32 | A previously active environmental flood alarm has cleared. | ||
| NTF envFuseCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.33 | Indicates that an environmental fuse alarm is raised. | ||
| NTF envFuseClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.34 | A previously active environmental fuse alarm has cleared. | ||
| NTF envGenCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.35 | Indicates that an environmental generator failure alarm is raised. | ||
| NTF envGenClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.36 | A previously active environmental generator failure alarm has cleared. | ||
| NTF envGenericCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.37 | Indicates that an environmental generic alarm is raised. | ||
| NTF envGenericClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.38 | A previously active environmental generic alarm has cleared. | ||
| NTF envHiAirCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.39 | Indicates that an environmental high airflow alarm is raised. | ||
| NTF envHiAirClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.40 | A previously active environmental high airflow alarm has cleared. | ||
| NTF envHiHumCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.41 | Indicates that an environmental high humidity alarm is raised. | ||
| NTF envHiHumClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.42 | A previously active environmental high humidity alarm has cleared. | ||
| NTF envHiTempCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.43 | Indicates that an environmental high temperature alarm is raised. | ||
| NTF envHiTempClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.44 | A previously active environmental high temperature alarm has cleared. | ||
| NTF envHiWindCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.45 | Indicates that an environmental high wind alarm is raised. | ||
| NTF envHiWindClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.46 | A previously active environmental high wind alarm has cleared. | ||
| NTF envHiWtrCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.47 | Indicates that an environmental high water alarm is raised. | ||
| NTF envHiWtrClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.48 | A previously active environmental high water alarm has cleared. | ||
| NTF envIceBuildupCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.49 | Indicates that an environmental ice buildup alarm is raised. | ||
| NTF envIceBuildupClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.50 | A previously active environmental ice buildup alarm has cleared. | ||
| NTF envIntruderCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.51 | Indicates that an environmental intrusion alarm is raised. | ||
| NTF envIntruderClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.52 | A previously active environmental intrusion alarm has cleared. | ||
| NTF envLwBatvgCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.53 | Indicates that an environmental low battery voltage alarm is raised. | ||
| NTF envLwBatvgClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.54 | A previously active environmental low battery voltage alarm has cleared. | ||
| NTF envLwFuelCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.55 | Indicates that an environmental low fuel alarm is raised. | ||
| NTF envLwFuelClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.56 | A previously active environmental low fuel alarm has cleared. | ||
| NTF envLwHumCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.57 | Indicates that an environmental low humidity alarm is raised. | ||
| NTF envLwHumClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.58 | A previously active environmental low humidity alarm has cleared. | ||
| NTF envLwPresCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.59 | Indicates that an environmental low cable pressure alarm is raised. | ||
| NTF envLwPresClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.60 | A previously active environmental low cable pressure alarm has cleared. | ||
| NTF envLwTempCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.61 | Indicates that an environmental low temperature alarm is raised. | ||
| NTF envLwTempClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.62 | A previously active environmental low temperature alarm has cleared. | ||
| NTF envLwWtrCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.63 | Indicates that an environmental low water alarm is raised. | ||
| NTF envLwWtrClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.64 | A previously active environmental low water alarm has cleared. | ||
| NTF envMiscCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.65 | Indicates that an environmental miscellaneous alarm is raised. | ||
| NTF envMiscClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.66 | A previously active environmental miscellaneous alarm has cleared. | ||
| NTF envOpenDrCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.67 | Indicates that an environmental open door alarm is raised. | ||
| NTF envOpenDrClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.68 | A previously active environmental open door alarm has cleared. | ||
| NTF envPowerCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.69 | Indicates that an environmental power failure alarm is raised. | ||
| NTF envPowerClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.70 | A previously active environmental power failure alarm has cleared. | ||
| NTF envPumpCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.71 | Indicates that an environmental pump failure alarm is raised. | ||
| NTF envPumpClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.72 | A previously active environmental pump failure alarm has cleared. | ||
| NTF envRectCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.73 | Indicates that an environmental rectifier failure alarm is raised. | ||
| NTF envRectClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.74 | A previously active environmental rectifier failure alarm has cleared. | ||
| NTF envRectHiCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.75 | Indicates that an environmental rectifier high voltage alarm is raised. | ||
| NTF envRectHiClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.76 | A previously active environmental rectifier high voltage alarm has cleared. | ||
| NTF envRectLoCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.77 | Indicates that an environmental rectifier low voltage alarm is raised. | ||
| NTF envRectLoClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.78 | A previously active environmental rectifier low voltage alarm has cleared. | ||
| NTF envSmokeCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.79 | Indicates that an environmental smoke alarm is raised. | ||
| NTF envSmokeClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.80 | A previously active environmental smoke alarm has cleared. | ||
| NTF envToxicGasCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.81 | Indicates that an environmental toxic gas alarm is raised. | ||
| NTF envToxicGasClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.82 | A previously active environmental toxic gas alarm has cleared. | ||
| NTF envVentnCond | 1.3.6.1.4.1.18070.2.2.2.2.27.0.83 | Indicates that an environmental ventilation system failure alarm is raised. | ||
| NTF envVentnClear | 1.3.6.1.4.1.18070.2.2.2.2.27.0.84 | A previously active environmental ventilation system failure alarm has cleared. | ||
| olCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.28 | |||
| erpsCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.29 | |||
| swMemberCondNotifications | 1.3.6.1.4.1.18070.2.2.2.2.30 | |||
| dbChangeNotifications | 1.3.6.1.4.1.18070.2.2.2.3 | |||
| NTF dbChangeEvt | 1.3.6.1.4.1.18070.2.2.2.3.0.2 | This message indicates that a change has been made in the value of the provisioned object identified by the dbChangeOID Var-Bind. If multiple objects have been changed in the same transaction, there will be multiple occurrances of the dbChangeOID object listed in the Var-Bind list. | ||
| NTF dbChangeSecuEvt | 1.3.6.1.4.1.18070.2.2.2.3.0.3 | This message indicates that a change has been made in the value of the SNMP community string, SNMP trap reciever, or Tl1User. | ||
| dbChangeNotificationsObjects | 1.3.6.1.4.1.18070.2.2.2.3.1 | |||
| DAT dbChangeDateAndTime | 1.3.6.1.4.1.18070.2.2.2.3.1.1 | DateAndTime | accessible-for-notify | The date and time at which a database change notification was issued by the system. |
| U32 dbChangeSeqNum | 1.3.6.1.4.1.18070.2.2.2.3.1.2 | Unsigned32 | accessible-for-notify | A integer value indicating the place of a database change notification message within the continual sequence of all database messages issued by the system. |
| OID dbChangeOID | 1.3.6.1.4.1.18070.2.2.2.3.1.3 | OBJECT IDENTIFIER | accessible-for-notify | The OID of the object instance whose value has been changed in the database. |
| notificationObjects | 1.3.6.1.4.1.18070.2.2.2.4 | |||
| U32 trapSeqNum | 1.3.6.1.4.1.18070.2.2.2.4.1 | Unsigned32 | read-only | A integer value indicating the place of the trap notification message within the continual sequence of all notification messages issued by the system. |
| notificationControl | 1.3.6.1.4.1.18070.2.2.2.5 | |||
| condNotifCtrl | 1.3.6.1.4.1.18070.2.2.2.5.1 | |||
| condNotifCtrlTable | 1.3.6.1.4.1.18070.2.2.2.5.1.1 | not-accessible | This table contains one row for every condition notification associated with a raise. | |
| condNotifCtrlEntry | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1 | not-accessible | The conceptual row object of the condition notification control table. | |
| OID condNotifObjId | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.1 | OBJECT IDENTIFIER | not-accessible | The specific condition notification to set the severity for. The value must correspond to the raise condition not the clear. |
| CON condNotifSeverity | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.2 | CondSeverity | read-write | The severity associated with the condition notification. - Only certain values are permitted for the set: default, critial, major, minor, notAlarmed. - Only certain values are visible for the get: critial, major, minor, major-minor, notAlarmed |
| CON condNotifDefaultSeverity | 1.3.6.1.4.1.18070.2.2.2.5.1.1.1.3 | CondSeverity | read-only | The default severity associated with the condition notification. Only certain of the CondSeverity values are visible: critial, major, minor, major-minor, notAlarmed |
| envCondAttrTable | 1.3.6.1.4.1.18070.2.2.2.5.1.2 | not-accessible | This table is used to manage the configuration of environmental alarm inputs. It contains one row for each environmental condition input on the NE. | |
| envCondAttrEntry | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1 | not-accessible | The conceptual row object of the environmental condition attribute table. | |
| INT envCondAttrHKIIdx | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.1 | INTEGER | not-accessible | The number of the housekeeping input which drives the activation of the environmental condition configured by this entry of the table. |
| CON envCondAttrSeverity | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.2 | CondSeverity | read-write | The severity reported for the configured environmental condition when it is raised. The valid values are: - minor - major - critical - notAlarmed |
| ENV envCondAttrCodeType | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.3 | EnvNotifCodeType | read-write | The code for the specific environmental condition that is reported when the housekeeping input indicates that the condition is active. |
| STR envCondAttrDescription | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.4 | DisplayString | read-write | The textual decription of the environmental condition that is reported when the condition is raised. |
| INT envCondAttrInputType | 1.3.6.1.4.1.18070.2.2.2.5.1.2.1.5 | INTEGER | read-write | Specifies how the housekeeping input which drives the reporting of the environmental condition is interpreted. |
| eventNotifCtrl | 1.3.6.1.4.1.18070.2.2.2.5.2 | |||
| INT eventNotifState | 1.3.6.1.4.1.18070.2.2.2.5.2.1 | INTEGER | read-write | Allows all events to be either disabled or enabled. |
4,153 OIDs total — showing 3,011-4,153 (page 2 of 2)
« Prev Page 2 of 2