Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::oaCaseTempCond

OID (numeric): 1.3.6.1.4.1.18070.2.2.2.2.6.0.1

Node type: NOTIFICATION-TYPE

Description: A case temperature high threshold is exceeded. A warning is raised to indicate that the amplifier is nearing its shutdown threshold. The circuit pack in the associated slot has exceeded its case temperature high threshold. If the case temperature continues to rise to its shutdown threshold, the circuit pack automatically shuts down.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' BTI-7000-MIB::oaCaseTempCond
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.18070.2.2.2.2.6.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:55305->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (329796105) 38 days, 4:06:01.05
  SNMPv2-MIB::snmpTrapOID.0 = OID: BTI-7000-MIB::oaCaseTempCond

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::oaCaseTempCond OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.2notificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2conditionNotificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2.6oaCondNotificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2.6.0.1oaCaseTempCondBTI-7000-MIB