BTI-7000-MIB :: oaBackReflectionSafetyCond

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBoaBackReflectionSafetyCond

oaBackReflectionSafetyCond

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::oaBackReflectionSafetyCond

OID (numeric): 1.3.6.1.4.1.18070.2.2.2.2.6.0.17

Node type: NOTIFICATION-TYPE

Description: The Optical Back Reflection - High Threshold Safety Override alarm indicates someone has activated the optical power received optical back reflection high threshold safety override (OPR-OBR-HTSO) command to override the automatic power reduction (APR) feature of the amplifier lasers. This command overrides the APR feature of the amplifier for 20 to 600 seconds. When the timer expires, the alarm clears.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' BTI-7000-MIB::oaBackReflectionSafetyCond
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.18070.2.2.2.2.6.0.17

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:56126->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (330297662) 38 days, 5:29:36.62
  SNMPv2-MIB::snmpTrapOID.0 = OID: BTI-7000-MIB::oaBackReflectionSafetyCond

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::oaBackReflectionSafetyCond OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.2notificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2conditionNotificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2.6oaCondNotificationsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.2.2.6.0.17oaBackReflectionSafetyCondBTI-7000-MIB